• DC insulation resistance with test voltages up to 1000V• PE conductor continuity test• Loop and Line impedance also without RCD triggering• RCD test• Illumination• Phase sequence in 3-phase systems• Measurements on earthling and lightning systems with included 2-clamp method (without junctions disassembling).• Electrical power and consumption measurement,• current and voltage harmonics measurement,• phase angle
• Measurement of step voltage and contact voltage.• Measurement of earthing resistance with resolution of 1 m?.• Measurement of specific earth resistance.• High current of up to 50 A and effective suppression of noise• Excellent immunity even against changing earth currents.• Autonomous Step Voltage meter: no need for long voltage leads.• Downloads test results directly to the PC with the help of the professional PC SW package HVLink
• Insulation Resistance: Three different test voltages (250, 500 and 1000 V) • Continuity: 200 mA measurement with automatic polarity change.• RMS Voltage and Frequency• Warnings are given if hazardous voltages are detected.• Auto power-off.
• Very large LCD display with bargraph and backlight• High measuring range of up to 30 G? with test voltage from 50 V to 1000 V• Fast and reliable continuity tests with automatic polarity reversal• Voltage and frequency measurements• Preprogrammed limits• PASS/FAIL evaluation of result• Bright GREEN/RED indicators provides visual evaluation of results• Suited for testing on CAT IV installations
• Adjustable test voltage from 250 V to 5000 V in 50 V steps.• Resistance measuring range 5 T?.• Adjustable measuring time from 1 second to 90 minutes.• Automatic PI, DAR and DD index calculation and capacitance measurement up to 50µF.• Automatic load discharge after completed measurement.• Guard terminal for elimination of insulation surface currents.• AC and DC voltage measurement up to 600 V.
• Five pre-set test voltages: 250V, 500V, 1000V, 2500V and 5000V • up to 1 T? for insulation resistance • 600 V for voltage measurements • Quick setting - Quick & Easy test voltage selection • Faster testing - 5 mA current source for quick charging of capacitive loads • Safe - High CAT IV, 600 V voltage protection • Easy to read - Large, bright LCD display with backlight
• Pre-set test voltages: 250V...5000V• Automated testing - PI, DD, DAR calculations with automated resistance ranging (AR)• Fault finding • R(t) graph - Real time resistance against time graph plotting facility • Faster testing - High 5 mA charging current quickly charges capacitive loads.• Accurate • Safe - High CAT IV, 600 V voltage protection
• Insulation resistance up to 10 T?• DC Test voltage 500 V - 10 kV in step of 25 V• The short circuit current is 5 mA• Auto-calibation of measuring system• Operates from mains or rechargeable supply• Automatic discharge of capacitive loads• Digital and bar graph results with date and time• User friendly PC software with RS232 or USB isolated communication port
• Measurements on earthing and lightning protection systems include: standard 4-wire method, standard 4-wire method with current clamps and 2-clamp method without junctions disassembling. • Specific earth resistance (soil resistance). • DC insulation resistance measurement with test voltages from 50 V up to 1000 V in 10 V steps. Measuring range up to 30 GOhm.
• Voltage testing up to 1000 V• Automatic AC/DC recognition• Continuity testing up to 2000 ?• Phase & Rotating Field Test RCD fault test• Diode Test• Auto Power Off• Data Hold• LCD display with backlight
• Voltage testing up to 1000 V• Automatic AC/DC recognition• Continuity buzzer and led to indicate resistances below 500 k?• Phase & Rotating Field Test• RCD trip testing• Diode Test• Auto Power Off
• Functional and visual inspection;• Earth bond resistance;• Insulation resistance;• Substitute leakage current;• Differential leakage current test;• Touch leakage test;• IEC cord polarity test;
• 12 V … 1000 V AC measurement range• Optical and vibrating indication• CAT III / 1000 V overvoltage protection
• 110 V … 1000 V AC measurement range• CAT III / 1000 V overvoltage protection• visual display indicator
• Continuity test with 200 mA.• Insulation resistance.• Insulation resistance of isolated accessible conductive parts.• Substitute leakage current.• Substitute leakage current of isolated. accessible conductive parts.• IEC cord polarity test.• Voltage.• Functional and visual inspection.
• Functional and visual inspection• Earth bond resistance• Insulation resistance• Insulation resistance of isolated accessible conductive parts• Substitute leakage current• Substitute leakage current of isolated accessible conductive parts• Differential leakage current test• Touch leakage test• PRCD test
• Earth bond / continuity resistance (200 mA)• Insulation resistance• Insulation resistance of isolated accessible conductive parts• Substitute leakage current• Substitute leakage current of isolated accessible conductive parts• Differential leakage current• Touch leakage current• IEC cord polarity test
• Earth bond / continuity resistance (200 mA, 10 A)• Insulation resistance• Insulation resistance of isolated accessible conductive parts• Substitute leakage current• Substitute leakage current of isolated accessible conductive parts• Differential leakage current• Touch leakage current• IEC cord polarity test
• Continuity tests (200 mA, 4 A, 10 A, 25 A).• Insulation resistance.• Substitute leakage current.• Differential leakage current.• Touch leakage current.• IEC cord polarity test.• Leakage and load TRMS current measurement with current clamp.
• All tests on 3-phase electrical equipment can be carried out, including live leakage test, power, polarity, RCD and Active polarity.• Simple connection to the PAT/MACHINE tester with automatic detection.• Simple test procedures, identical to single phase equipment.• Test sequence for 3-phase tests are automatically set, based on entered test codes and input voltages.
• Testing of single and 3-phase ARC Welding equipment.• Professional 3-phase portable appliance testing.• Professional 3-phase machine testing• Testing of Open-Circuit Voltage at ARC Welding Units in accordance to EN 60974-4.• All tests on 3-phase electrical equipment can be carried out including live leakage test, power, polarity, RCD and Active polarity.• Simple connection to the PAT/MACHINE tester with automatic detection
• High precision line impedance;• High precision fault loop impedance;• Contact voltage.• Range widening: adapts the instruments to read from 0.1 m? up to 19.99 ?.• Multi-system testing: works on both single phase and 3-phase systems (110 V to 440 V).
• Field proven instrument for under-wall low voltage installation tracing• fuse finding• short-circuit spot determination and metal installation tracing• Can be used on energized or voltage-free systems.• Tips and detailed descriptions of connection schemes for various combinations from everyday practice.
• Wiring check• DC insulation resistance• Continuity test• Line and Loop resistance• RCD test• Phase sequence• Pass/Fail visual and audio presentation of results
• Loop impedance / prospective fault current• Line impedance / prospective short-circuit current• Built-in fuse characteristics for quick evaluation of measuring results• RCD tests (trip out time, contact voltage, ramp test, Autotest)• Testing on 1- and 3-phase systems• Phase sequence test
• Insulation resistance up to 100 GO with DC voltage up to 2.5 kV;• PI, DAR calculation;• Continuity of PE conductors with 200 mA test current and polarity change;• Continuity of PE conductors with 7 mA test current (continuous measurement) without RCD tripping;• TRMS voltage and frequency.
• TRMS voltage and frequency• Continuity• Insulation resistance• RCD testing (type AC and A)• Fault loop / RCD Trip Lock impedance• Line impedance• Phase sequence
• IT System recognizing, Voltage Range and Voltage Balance;• ISFL Single Fault Leakage current from Phase 1 and Phase 2 to PE;• Fuse Trip-out Ability Evaluation, Line Impedance and Ipsc Prospective Short Circuit Current;• IMD Insulation / ELM Earth Leakage / RCM Residual Current Monitor Devices Control;• Alarm Trigger or Trip-Out Check and Adjust.
• insulation resistance,• PE conductor continuity test,• Line and Loop esistances with Fuse evaluation table built-in,• RCD test with Trip lock function,• phase sequence in 3-phase systems,• on-line voltage monitor,• 2-wire and 3-wire Earth resistance test with built-in battery operated generator,• earth resistance test with Two Clamps method,• Leakage Current test,• test of Luminance with optional LUX meter probe
• DC insulation resistance,• PE conductor continuity test,• Line and Loop resistances with Fuse evaluation table built-in, RCD test with Trip lock function,• phase sequence in 3-phase systems,• on-line voltage monitor,• 2-wire and 3-wire Earth resistance test with built-in battery operated generator.
• DC insulation resistance,• PE conductor continuity test,• Line and Loop resistances with Fuse evaluation table built-in,• RCD test with Trip lock function, phase sequence in 3-phase systems,• on-line voltage monitor,• 3-wire Earth resistance test with built-in battery operated generator,• Leakage Current test,• test of Luminance with optional LUX meter probe.
• Insulation resistance with up to 2500V DC voltage • PI, DAR calculation• Continuity of PE conductors with 200 mA test current with polarity change• Continuity of PE conductors with 7 mA test current (continuous measurement) without RCD tripping• Line impedance• Loop impedance• Loop impedance with Trip Lock RCD function• TRMS voltage and frequency
• DC insulation resistance,• PE conductor continuity test,• Line and Loop resistances with Fuse characteristics inside the instrument,• RCD test with Trip lock function,• phase sequence in 3-phase systems,• on-line voltage monitor.
• Insulation resistance with DC voltage• Continuity of PE conductors with 200 mA test current with polarity change• Continuity of PE conductors with 7 mA test current (continuous measurement) without RCD tripping• Line impedance• Loop impedance• Loop impedance with Trip Lock RCD function• TRMS voltage and frequency• Phase sequence• RCD testing (general and selective, type AC, A and B)• Earth resistance (3-wire method).