• Wide voltage range from 0 to 1000 V DC/AC with accuracy 0.01 %• Extended current range from 0 to 20 A DC/AC with accuracy 0.02 %• Extended current range to 1000 A for calibration of clamp ammeters• Sinusoidal & Non-sinusoidal waveforms• Fix standard resistors 10 O to 100 MO in decimal values with calibration accuracy 0.02 %• Thermocouple temperature sensor simulation R, S, B, J, T, E, K, N in range from 250 °C to 1850 °C• Cold junction automatic compensation using external Pt1000 sensor• RTD temperature sensor simulator as option
• 15ppm Accuracy• DC/AC voltage up to 1000 V• DC/AC current up to 30 A• Resistance up to 1000 MO, capacitance up to 100 uF• TC/RTD temperature sensors simulation• Frequency output up to 20 MHz• Electric power up to 240 V / 20 A• Built-in process multimeter• GPIB & RS232 interface
• 15ppm Accuracy• DC/AC voltage up to 1000 V• DC/AC current up to 30 A• TC temperature sensors simulation• RS232 interface
• 35ppm Accuracy• DC/AC voltage up to 1000 V• DC/AC current up to 20 A• Resistance up to 50 MO, capacitance up to 50 µF• TC/RTD temperature sensors simulation• Frequency output up to 20 MHz• Electric power up to 240 V / 10 A• Built-in process multimeter• GPIB & RS232 interface
• 35ppm Accuracy• DC/AC voltage up to 1000 V• DC/AC current up to 20 A• TC temperature sensors simulation• RS232 interface
• 100ppm Accuracy• DC/AC voltage up to 750 V• DC/AC current up to 2 A• Fix standard resistors from 10 O to 10 MO in decade values • TC temperature sensors simulation• Frequency output up to 20 MHz• RS232 & GPIB (option) interface
• Total resistance range 10.00 k? to 1000.0 G?• Resistance accuracy 0.1 to 5 %• Test voltage range 10 000 VDC + 5%• Test voltage accuracy indication 0.5 % + 10 V• Test current indication 4 digit from 0.01 pA to 99.99 mADC• Programmable high resistance decade box• Short current verification• Dielectric and absorption parameters simulation: polarization index (PI), dielectric absorption ratio (DAR) and polarization ratio (PR)• High voltage capacitance in three fix points 10, 50, 100 nF• HIPOT timer verification
• Resistance standards from 0.1 O to 100 MO• Capacitance standards from 10 pF to 100 µF• Simulated inductance standards from 10 µH to 10 H• Four pair coaxial terminal connection, four terminal connection, two terminal connection • Calibration data from 20 Hz to 1 MHz• Interface bus GPIB and RS232 as standard
• Current 8 mA … 120 A (AC/DC) • Frequency 15 Hz … 1 kHz • Simulated current and transconductance amplifier • Built-in process multimeter• Output capability 8 Vpk• Interface bus GPIB and RS232 as standard• With current coil it can be used for calibration of clamp meters up to 3000 A