• Lown, Edmark, trapezoidal, biphasic and pulsed-biphasic defibrillation technology compatibility • AED technology compatibility • First-class measurement accuracy ± 1 % of reading + 0.1 J • Intuitive user interface and backlight, easy-to-read display • Portable, rugged, easy to carry
• Portable, ergonomic, lightweight, and easy to use • Large, easy-to-read display with adjustable contrast • Human-factors-designed user interface • Tilt stand design for stand-up testing in field environments • Five applied parts jacks and easy ECG snap connection
• Compliance with multiple standards • Three test loads • Expanded leakage ranges through 10,000 µA • AC only, DC only and True RMS leakage readings • 100 % and 110 % mains voltage for mains on applied part (lead isolation) test • 20 A equipment current
• EN60601-1, EN601010-1, and AAMI test loads (user selectable) • Multiple enclosure-leakage points • Multiple patient-applied-part types • Power ON/OFF delay • DC only for patient- and auxiliary-leakage tests • User-programmable test sequences
• Easy verification of biomedical equipment to manufacturer’s specifications • Ten preprogrammed and five user-programmable electrical-safety-testing sequences • Convenient transfer of equipment inventory and testing procedures from CMMS • Automatic storage of detailed test results for printing or transfer to CMMS • Compliant with ANSI/AAMI (1993) and NFPA-99 (2005) standards • 20-A device testing with GFCI protection
• Ultra-portable (fitting in a briefcase) • IEC601-1 and AAMI test loads • Self-switching 120/240 V operation • Point-to-point testing
• Handheld portability (fitting in a briefcase) • Self-switching 120/240 V operation • Patient-lead-leakage testing • 15 A and 20 A capabilities • Digital accuracy • Dual-lead testing
• Handheld • Stand-alone operation • Direct measurement of leakage current • Battery-operated • Independent of 120 V or 240 V systems • Built-in self-test circuit • Auto shut-off to conserve battery
• Small, lightweight, self-contained portable instrument • Master range meter delivers accurate measurment for each test • Accurate test measurements with 4-wire Kelvin bridge • Test method complies with AAMI load per ANSI/AAMI ES1-1993 or IEC601-1 • Leakage Current can be measured in Open/Closed Neutral, Normal/Reversed Polarity and Open/Closed Ground • All Leakage Current measurements are displayed directly in µAmps • Broad range of external measurements • Five (5) Universal EKG Lead Connectors • The DALE601E is designed for 230 V operation
• Small, lightweight, self-contained portable instrument • Universal Power Supply. Input voltage from 85 - 265 VAC • Chassis Resistance measurements are made with a four-wire Kelvin bridge to eliminate errors due to cable length • Test method complies with AAMI load per ANSI/AAMI ES1-1993
• Automatic power distribution measurement, including power, current, peak-to-peak voltage closed load only), and crest factor • High-frequency leakage measurements with accuracy of ± 2 % of reading • 128 internal user-selectable test loads from 10 O to 5200 O • Ansur QA-ES software plug-in for automated test protocols • RS-232 and Centronic-printer interface
• New Signal Averaging Mode (SAMTM) • New RS232 port • Battery powered for completely isolated measurement • Digital display • HF-leakage-current measurement • 4-digit numeric LCD with backlight and power-save mode
• Unique digital circuitry retains measurement • Direct reading of Line Voltage, LIM and GFI current • 9 volt battery operation • Universal voltages from 85 to 245 VAC, 50/60 Hz • Small, lightweight, very portable
• Incoming acceptance inspection performed • Simple to use • Lightweight and companct • No light source or other accessories required
• Dual input – 200, 100 or 60 MHz bandwidth • Up to 2.5 GS/s real-time sampling per input • Connect-and-View™ automatic triggering and a full range of manual trigger modes • Digital Persistence for analyzing complex dynamic waveforms, similar to an analog scope • Fast-display update rate for seeing dynamic behavior instantaneously • Automatic capture and replay of 100 screens • 27,500 points-per-input record length using ScopeRecord mode
• Choice of all-in-one detector, dosimeter, integral ma/mAs and handheld display or user’s own laptop interface. • 100 % ZigBee wireless operation • Compact handheld design • Sets up in seconds • Displays all values in one shot (all-in-one detector)
• Tests up to four infusion pumps simultaneously • Compatible with virtually any type of infusion device • Instantaneous and average flow measurement • Occlusion pressure measurements to 45 psi • Single- and dual-flow (piggyback) testing