Brand: FLUKE BIOMEDICAL

Analizor securitate electrica Fluke Biomedical DALE 601E

Cod: Fluke Biomedical DALE 601E


 

Descriere

  • Small, lightweight, self-contained portable instrument
  • Master range meter delivers accurate measurment for each test
  • Accurate test measurements with 4-wire Kelvin bridge
  • Test method complies with AAMI load per ANSI/AAMI ES1-1993 or IEC601-1
  • Leakage Current can be measured in Open/Closed Neutral, Normal/Reversed Polarity and Open/Closed Ground
  • All Leakage Current measurements are displayed directly in µAmps
  • Broad range of external measurements
  • Five (5) Universal EKG Lead Connectors
  • The DALE601E is designed for 230 V operation

 

 

Specifications

Mains Voltage

 

 230 Volts, 50/60 Hz

Instrument Current

Range:

 0 - 10.00 Amps

Resolution:

 10 mA

Accuracy:

 5 % R

Ground (Earth) Resistance

Range: 0 - 1.99

 Accuracy: 1% R ± 1 LSD

              2 - 19.99

 Accuracy: 2 % R ± 1 LSD

Resolution:

 10 mOhms

Leakage Current

Range:

 0 - 1, 999 µA

Accuracy:

 DC & 25 Hz - 1kHz: ±1% of reading, ± 3LSD

 

 1.0KHz - 100 KHz: ±2.5% of reading, ± 3LSD

 

 100 KHz - 1 MHz: ±5% of reading, ± 3LSD

Type Measurement:

 True RMS

Test Load:

 AAMI or IEC601-1 (selectable)

Current Consumption

Range:

 0-14.99A(Dale 601-1515)

 

 0-19.99A(Dale 601-1520/2020)

 

 0-9.99A(Dale 601E)

Current Capacity

Dale 601-1515

 15Amps

Dale 601E

 10Amps

Dale 601-1520/2020

 20Amps, 20% duty cycle (2 minutes on, 8 minutes off)

Controls

 

 1. Function Switch - 9 position rotary

 

 2. Lead Switch - 6 position rotary

 

 3. Neutral Switch - 2 position rocker (Open/Closed)

 

 4. Polarity Switch - 3 position rocker (Normal/Off/Reversed)

 

 5. Leakage Switch - 2 position rocker (Chassis/Earth)

DUT Power

 

 10 Amps @ 230 V

Physical Size

 

 4.0 x 7.8 x 1.6 inches (102 x 196 x 41 mm)

 

Alte produse FLUKE BIOMEDICAL

TESTER PORTABIL SECURITATE ELECTRICA FLUKE BIOMEDICAL 175

• Handheld portability (fitting in a briefcase)
• Self-switching 120/240 V operation
• Patient-lead-leakage testing
• 15 A and 20 A capabilities
• Digital accuracy
• Dual-lead testing

 

RATMETRU DIGITAL UNIVERSAL MONITORIZARE RADIATII FLUKE BIOMEDICAL 942A/ 946A/ 952A

• User adjustable alarm set-points; retained indefinitely on power outage, keylock protection available
• Front panel pushbuttons for check source activation, high voltage indication, alarm setpoint indication, alarm acknowledge, and power ON/OFF
• Small front panel size allows dedicated display for each channel while minimizing panel space
• Ability to use existing cables when replacing most analog readouts

 

TESTER IZOLATIE CURENTI LIM/ GFI FLUKE BIOMEDICAL DALE2000

• Unique digital circuitry retains measurement
• Direct reading of Line Voltage, LIM and GFI current
• 9 volt battery operation
• Universal voltages from 85 to 245 VAC, 50/60 Hz
• Small, lightweight, very portable


ANALIZOR SECURITATE ELECTRICA FLUKE BIOMEDICAL DALE 601E

• Small, lightweight, self-contained portable instrument
• Master range meter delivers accurate measurment for each test
• Accurate test measurements with 4-wire Kelvin bridge
• Test method complies with AAMI load per ANSI/AAMI ES1-1993 or IEC601-1
• Leakage Current can be measured in Open/Closed Neutral, Normal/Reversed Polarity and Open/Closed Ground
• All Leakage Current measurements are displayed directly in µAmps
• Broad range of external measurements
• Five (5) Universal EKG Lead Connectors
• The DALE601E is designed for 230 V operation


TESTER MONITORIZARE NEUTRONI FLUKE BIOMEDICAL 190N

• Auto-scaling measurement of rate and dose (integrate mode includes dose and time accumulation)
• True Rem readings recorded across a wider (lower and higher) rate range
• Ergonomic, portable design: adjustable shoulder strap and rugged handle with padded grip
• Flexible detector assembly, 190 can be removed for remote readings
• Available in SI units


TESTER PNEUMATIC GENERARE/ MASURA PRESIUNI POZITIVE/ NEGATIVE FLUKE BIOMEDICAL DPM1B

• Battery operated
• Generates and measures positive or negative pressures
• Operates with gas and liquid
• Troubleshooting with 1 % accuracy

 

TESTER ENDOSCOAPE RIGIDE FLUKE BIOMEDICAL DALE301

• Incoming acceptance inspection performed
• Simple to use
• Lightweight and companct
• No light source or other accessories required


TESTER MULTIFUNCTIONAL DEBIT, VOLUM, VID, PRESIUNE, CONCENTRATIE OXIGEN FLUKE BIOMEDICAL VT MOBILE

• Bidirectional flow (high- and low-flow ranges), volume, vacuum, pressure, and oxygen-concentration measurements
• 16 ventilator parameter measurements
• Trending and statistical analysis of all measured values
• Onboard graphical display
• Portable and compact
• RS232 for computer control
• Memory for storing results
• VT for Windows PC software

 

TESTER ULTRASUNETE SECURITATE ELECTRICA FLUKE BIOMEDICAL ULT800

• Handheld
• Stand-alone operation
• Direct measurement of leakage current
• Battery-operated
• Independent of 120 V or 240 V systems
• Built-in self-test circuit
• Auto shut-off to conserve battery

 

DEFIBRILATOR STIMULARE IMPULSURI FLUKE BIOMEDICAL 6000D/ 7000DP

• Lown, Edmark, trapezoidal, biphasic and pulsed-biphasic defibrillation technology compatibility
• AED technology compatibility
• First-class measurement accuracy ± 1 % of reading + 0.1 J
• Intuitive user interface and backlight, easy-to-read display
• Portable, rugged, easy to carry