• Resistance range 1.000 00 O - 1.200 000 MO• Accuracy 0.003%• Maximal voltage 200Vpk• Resolution from 10 µO• Range of Pt sensor temperature simulation -200°C - +850°C• Connection 2, 3, 4-wire• Remote control RS232, optionally USB, IEEE488, Ethernet
• Resistance range 1.000 00 O - 1.200 000 MO• Accuracy 0.005%• Resolution from 10 µO• Range of Pt sensor temperature simulation -200°C - +850°C• Connection 2, 3, 4-wire• Remote control RS232, optionally IEEE488• Internal ACCU/power line adapter
• Resistance range from 0.1 O to 10 MO with accuracy 0.02 %• Temperature coefficient < 25 ppm/°C• Max. load 2 W (120 V and 0.6 A)• RTD (Pt, Ni) simulation with accuracy 0.2 °C• Power supplying from power line adaptor or from internal battery• Interface RS232 (IEEE488 optionally)• Table version (19“ module as option)
• Calibration of temperature controllers• Resistance range from 16 O to 10 kO• Simulation of Pt and Ni sensors• Accuracy +/- 0.02°C• Temperature stability < 1 ppm/°C• Simulation of cable resistances• Interface RS 232 (IEEE488 optionally)
• Total resistance range 10.00 k? to 1000.0 G?• Resistance accuracy 0.1 to 5 %• Test voltage range 10 000 VDC + 5%• Test voltage accuracy indication 0.5 % + 10 V• Test current indication 4 digit from 0.01 pA to 99.99 mADC• Programmable high resistance decade box• Short current verification• Dielectric and absorption parameters simulation: polarization index (PI), dielectric absorption ratio (DAR) and polarization ratio (PR)• High voltage capacitance in three fix points 10, 50, 100 nF• HIPOT timer verification
• Resistance range from 15 O to 300 kO• Maximal load 3kW, maximal voltage 250 Vrms• Accuracy 0.1 %• Temperature coefficient < 10 ppm/°C• Interface RS - 232 (IEEE488 optionally)• Table version (19“ module as option)
• Resistance standards from 0.1 O to 100 MO• Capacitance standards from 10 pF to 100 µF• Simulated inductance standards from 10 µH to 10 H• Four pair coaxial terminal connection, four terminal connection, two terminal connection • Calibration data from 20 Hz to 1 MHz• Interface bus GPIB and RS232 as standard
• Designed for RCL meters calibration• Range of capacitance from 100 pF to 12 mF• Basic accuracy 0.25 %• Maximal operating voltage 50 V• Power supplying from internal battery or power line adapter• Remote control RS-232
• Calibration of insulation meters and megaohm meters• Four decades• Resistance range 1 MO – 12 GO• Accuracy from 0.1 % to 1 %• Maximum working voltage 5 kVdc• Internal battery / power line adapter supplying• RS232 bus
• Resistance range 10 O to 1000 O• Very low frequency dependency• Applicable frequency range to 100 MHz• Calibration of wide frequency range LCR meters
• Resistance Capacitance Inductance standards• Traceability of electric quantities• Calibration of meters• Calibration uncertainty 0.005 %• Low time constant• Three/four terminal or four pair terminal connection