Brand: FLUKE BIOMEDICAL

Tester endoscoape rigide Fluke Biomedical DALE301

Cod: Fluke Biomedical DALE301


 

Descriere

A simple-to-use, quick check for rigid endoscopes.

Finally, there is a simple tool for technical and non-technical personnel to perform a quick evaluation of most rigid endoscopes. With the DALE301, your staff diagnoses problems during incoming inspections, after complaints, pre- and post-service, and as a routine preventive-maintenance inspection.

With the DALE301, you can identify the following:

 

  • Broken lenses
  • Crooked rod shaft
  • Normal wear and tear
  • Internal moisture
  • Presence of contamination
  • Lens debris

 

Features

  • Incoming acceptance inspection performed
  • Simple to use
  • Lightweight and companct
  • No light source or other accessories required
  • Pre-repair inspections to prevent unneeded repairs and save money
  • Post-repair inspections to verify a performed service or indicate if a repair was simply a "dusting-off"
  • Compatible with most rigid endoscopes
  • Compatible with common cameras for hard copy documentation to trend test or to compare and decument service

 

 

Specifications

Outer Diameter of Eyepiece

 

 31.75 mm +0 -0.1 per DIN 58105

End-Cap Inner Diameter

 

 No less then 120 mm

Optical Design

Focal length:

 40 mm ± 3%

Refraction:

 25 dpt

Material:

 PMMA (Plexiglass)

Diameter:

 19 mm

Focal Point Adjustment Scale

 

 16 cm

Maximum Diameter of Rigid Endoscope

 

 <10 mm

Environmental

Operating Temperature:

 15 to 40 °C

Storage Temperature:

 -10 to +65 °C

Relative Humidity:

 95% max

Dimensions

 

 8.75" L x 1.75" W x 1.75" H

 

 (22 cm L x 4 cm W x 4 cm H)

Weight

 

 13.1 oz ( 370 g)

 

Alte produse FLUKE BIOMEDICAL

RATMETRU DIGITAL UNIVERSAL MONITORIZARE RADIATII FLUKE BIOMEDICAL 942A/ 946A/ 952A

• User adjustable alarm set-points; retained indefinitely on power outage, keylock protection available
• Front panel pushbuttons for check source activation, high voltage indication, alarm setpoint indication, alarm acknowledge, and power ON/OFF
• Small front panel size allows dedicated display for each channel while minimizing panel space
• Ability to use existing cables when replacing most analog readouts

 

ANALIZOR SECURITATE ELECTRICA FLUKE BIOMEDICAL DALE 601E

• Small, lightweight, self-contained portable instrument
• Master range meter delivers accurate measurment for each test
• Accurate test measurements with 4-wire Kelvin bridge
• Test method complies with AAMI load per ANSI/AAMI ES1-1993 or IEC601-1
• Leakage Current can be measured in Open/Closed Neutral, Normal/Reversed Polarity and Open/Closed Ground
• All Leakage Current measurements are displayed directly in µAmps
• Broad range of external measurements
• Five (5) Universal EKG Lead Connectors
• The DALE601E is designed for 230 V operation


TESTER DETECTOR RADIATII ALFA, BETA, GAMMA, RAZE X FLUKE BIOMEDICAL ASM-990

• Auto-scaling measurement of rate and dose simultaneously, with the capability to record peak rate
• Up to [5] different probes can be calibrated with one unit
• Survey Mode data logging feature allows user to store up to 5 separate survey sequences
• Saved data can be uploaded to a PC via included Infrared Data (IrDA) transmitter
• Easy-to-use multifunction keypad for intuitive menu navigation
• Backlit analog/digital LCD display with full-range audio output capability

 

ANALIZOR AUTOMAT SECURITATE ELECTRICA FLUKE BIOMEDICAL MEDTESTER 5000C

• Easy verification of biomedical equipment to manufacturer’s specifications
• Ten preprogrammed and five user-programmable electrical-safety-testing sequences
• Convenient transfer of equipment inventory and testing procedures from CMMS
• Automatic storage of detailed test results for printing or transfer to CMMS
• Compliant with ANSI/AAMI (1993) and NFPA-99 (2005) standards
• 20-A device testing with GFCI protection

 

ANALIZOR SECURITATE ELECTRICA FLUKE BIOMEDICAL 601 PRO

• EN60601-1, EN601010-1, and AAMI test loads (user selectable)
• Multiple enclosure-leakage points
• Multiple patient-applied-part types
• Power ON/OFF delay
• DC only for patient- and auxiliary-leakage tests
• User-programmable test sequences

 

TESTER PORTABIL SECURITATE ELECTRICA FLUKE BIOMEDICAL 175

• Ultra-portable (fitting in a briefcase)
• IEC601-1 and AAMI test loads
• Self-switching 120/240 V operation
• Point-to-point testing

 

ANALIZOR DEBIT FLUX GAZE FLUKE BIOMEDICAL VT PLUS HF

• Bi-directional flow, pressure, volume, and oxygen concentration, and pressure measurements
• Low- and high-pressure, and flow measurement capability
• Special HF mode-up to 900 BPM (15 Hz)
• RS-232 and printer ports
• Included Windows-compatible graphics software

 

TESTER MULTIFUNCTIONAL DEBIT, VOLUM, VID, PRESIUNE, CONCENTRATIE OXIGEN FLUKE BIOMEDICAL VT MOBILE

• Bidirectional flow (high- and low-flow ranges), volume, vacuum, pressure, and oxygen-concentration measurements
• 16 ventilator parameter measurements
• Trending and statistical analysis of all measured values
• Onboard graphical display
• Portable and compact
• RS232 for computer control
• Memory for storing results
• VT for Windows PC software

 

TESTER ULTRASUNETE SECURITATE ELECTRICA FLUKE BIOMEDICAL ULT800

• Handheld
• Stand-alone operation
• Direct measurement of leakage current
• Battery-operated
• Independent of 120 V or 240 V systems
• Built-in self-test circuit
• Auto shut-off to conserve battery

 

TESTER ENDOSCOAPE RIGIDE FLUKE BIOMEDICAL DALE301

• Incoming acceptance inspection performed
• Simple to use
• Lightweight and companct
• No light source or other accessories required