Brand: FLUKE BIOMEDICAL

Scopmetru Medical digital portabil 200 MHz Fluke Biomedical 199XRAY

Cod: Fluke Biomedical 199XRAY


 

Brosura produs PDF, 0.68 Mb

Descriere

  • Dual input - 200, 100 or 60 MHz bandwidth
  • Up to 2.5 GS/s real-time sampling per input
  • Connect-and-View™ automatic triggering and a full range of manual trigger modes
  • Digital Persistence for analyzing complex dynamic waveforms, similar to an analog scope
  • Fast-display update rate for seeing dynamic behavior instantaneously
  • Automatic capture and replay of 100 screens
  • 27,500 points-per-input record length using ScopeRecord mode
  • TrendPlot paperless chart recorder for trend analysis up to 22 days
  • Up to 1,000 V independently floating isolated inputs
  • Waveform reference for visual comparisons and automatic pass/fail testing of waveforms
  • Vpwm function for motor drive and frequency inverter applications
  • 1000 V CAT II and 600 V CAT III safety certified
  • Four-hours-rechargeable NiMH battery pack

 

  • ScopeMeter displays kVp wave forms and direct kVp values simultaneously on an easy-to-read screen
  • No more time spent calculating scope traces to derive kVp values
  • Full medical oscilloscope scope functionality with color display
  • ScopeMeter triggers on standard interlaced and high-resolution, non-interlaced video systems. Triggers on all lines non-selectively or select an individual video line - up to 2800 lines per frame
  • mAs measurement calculates current over time
  • Smart averaging capabilities
  • Extended vertical offset
  • Selectable persistence mode
  • Extended video triggering
  • FlukeView® for Windows® for documenting, enhancing, waveform analysis, and archiving results

 

mAs measurement calculates current over time
Using the cursors, you can now measure directly the amount of radiation produced by x-ray systems, or the total amount of charge applied to a system.

 
Smart averaging
Smart averaging gives the averaged waveform over successive acquisitions, reducing noise in the displayed waveform. Thanks to smart averaging, you can now also see an incidental curve of a different wave shape with no effect on the averaged curve. This allows you to see the averaged curve of a sequence of video lines, for example, while still seeing the incidental flyback line flash by. The oscilloscope gives an immediate response when the signal makes large changes.
 
Extended offset
Vertical offset is now extended to a maximum of 16 divisions, allowing vertical zoom-in for study of small details of the signal.
 
Selectable persistence
Persistence mode with selectable decay time helps to find anomalies in the wave shape and optimizes the display for color information when working with composite color video.
 
Extended video triggering
Along with its triggering capability for standard, interlaced TV signals, the instrument also triggers on high-resolution, non-interlaced video systems. The ScopeMeter 199XRAY will trigger on all lines (nonselective), or can select an individual video line from systems with up to 2800 lines per frame.
 
FlukeView® forWindows®
  • Documenting: Transfer waveforms, screens, and measurement data from the ScopeMeter to a PC. Print or import the data into your report.
  • Enhancing: Add user text to individual ScopeMeter settings, providing guidance to the operator when recalling a setup.
  • Archiving: Create a library of waveforms with your comments for easy reference and comparison. Store complete replay cycles for analysis of waveform changes. Store complete memory content of the ScopeMeter on your PC for backup purposes.
  • Waveform Comparison: Store reference waveforms, add operator instructions, and send both to the ScopeMeter for waveform comparison and "Pass/Fail" testing.
  • Analysis: Use cursors, perform spectrum analysis, or export data to other analysis programs.
 

Accesorii standard

199XRAY: Medical ScopeMeter 200 MHz bandwidth with kVp capabilities [includes the MA190 Medical ScopeMeter Accessory Kit: FlukeView® for Windows® software, 50 ohm BNC feed-through terminator, 50 ohm BNC terminator with 10:1 signal attenuation, 1 ohm current shunt for current measurements, safety-designed BNC cable (1.5 m/5 ft), insulated BNC (f) to 4 mm banana plug adapter, dual 4 mm banana receptacles (1 red, 1 black)]

 

Alte produse FLUKE BIOMEDICAL

TESTER PNEUMATIC GENERARE/ MASURA PRESIUNI POZITIVE/ NEGATIVE FLUKE BIOMEDICAL DPM1B

• Battery operated
• Generates and measures positive or negative pressures
• Operates with gas and liquid
• Troubleshooting with 1 % accuracy

 

TESTER PORTABIL SECURITATE ELECTRICA FLUKE BIOMEDICAL 175

• Ultra-portable (fitting in a briefcase)
• IEC601-1 and AAMI test loads
• Self-switching 120/240 V operation
• Point-to-point testing

 

ANALIZOR ECHIPAMENTE ELECTRO-CHIRURGIE FLUKE BIOMEDICAL RS303 RS

• New Signal Averaging Mode (SAMTM)
• New RS232 port
• Battery powered for completely isolated measurement
• Digital display
• HF-leakage-current measurement
• 4-digit numeric LCD with backlight and power-save mode

 

ANALIZOR AUTOMAT SECURITATE ELECTRICA FLUKE BIOMEDICAL MEDTESTER 5000C

• Easy verification of biomedical equipment to manufacturer’s specifications
• Ten preprogrammed and five user-programmable electrical-safety-testing sequences
• Convenient transfer of equipment inventory and testing procedures from CMMS
• Automatic storage of detailed test results for printing or transfer to CMMS
• Compliant with ANSI/AAMI (1993) and NFPA-99 (2005) standards
• 20-A device testing with GFCI protection

 

TESTER IZOLATIE CURENTI LIM/ GFI FLUKE BIOMEDICAL DALE2000

• Unique digital circuitry retains measurement
• Direct reading of Line Voltage, LIM and GFI current
• 9 volt battery operation
• Universal voltages from 85 to 245 VAC, 50/60 Hz
• Small, lightweight, very portable


ANALIZOR SECURITATE ELECTRICA FLUKE BIOMEDICAL 601 PRO

• EN60601-1, EN601010-1, and AAMI test loads (user selectable)
• Multiple enclosure-leakage points
• Multiple patient-applied-part types
• Power ON/OFF delay
• DC only for patient- and auxiliary-leakage tests
• User-programmable test sequences

 

DEFIBRILATOR STIMULARE IMPULSURI FLUKE BIOMEDICAL 6000D/ 7000DP

• Lown, Edmark, trapezoidal, biphasic and pulsed-biphasic defibrillation technology compatibility
• AED technology compatibility
• First-class measurement accuracy ± 1 % of reading + 0.1 J
• Intuitive user interface and backlight, easy-to-read display
• Portable, rugged, easy to carry

 

TESTER DOZIMETRU RADIATII RAZE X FLUKE BIOMEDICAL TNT 12000 X-RAY

• Choice of all-in-one detector, dosimeter, integral ma/mAs and handheld display or user’s own laptop interface.
• 100 % ZigBee wireless operation
• Compact handheld design
• Sets up in seconds
• Displays all values in one shot (all-in-one detector)

 

ANALIZOR SECURITATE ELECTRICA SALI MEDICALE FLUKE BIOMEDICAL ESA612

• Portable, ergonomic, lightweight, and easy to use
• Large, easy-to-read display with adjustable contrast
• Human-factors-designed user interface
• Tilt stand design for stand-up testing in field environments
• Five applied parts jacks and easy ECG snap connection

 

TESTER MULTIFUNCTIONAL DEBIT, VOLUM, VID, PRESIUNE, CONCENTRATIE OXIGEN FLUKE BIOMEDICAL VT MOBILE

• Bidirectional flow (high- and low-flow ranges), volume, vacuum, pressure, and oxygen-concentration measurements
• 16 ventilator parameter measurements
• Trending and statistical analysis of all measured values
• Onboard graphical display
• Portable and compact
• RS232 for computer control
• Memory for storing results
• VT for Windows PC software