Brand: FLUKE BIOMEDICAL

Tester camere ionizare radiatii beta, gamma, raze X Fluke Biomedical 451B

Cod: Fluke Biomedical 451B


 

Brosura produs PDF, 0.39 Mb
 

Descriere

The auto-ranging 451B measures radiation rate and accumulated dose from beta, gamma and x-ray radiation sources. The 451B’s site surveying capabilities make it well-suited for a wide range of end users, including: police and fire departments, x-ray manufacturers, government agencies, state inspectors, emergency response and HAZMAT teams, nuclear medicine labs, hospital radiation safety officers, and nuclear power workers. The ion chamber detector allows for a fast response time to radiation from leakage, scatter beams and pinholes. Additionally, the low noise chamber bias supply provides for fast background settling time. A sliding beta shield serves as an equilibrium thickness for photon measurements and enables beta discrimination. The digital display features an analog bar graph, 2.5 digit digital readout, low battery and freeze ("peak hold") mode indicators, and an automatic backlight function. User controls consist of an ON/OFF button and a MODE button. The case is constructed of lightweight, high strength materials and is sealed against moisture. The RS-232 interface can be connected directly to a computer for use with the Excel add-in for Windows (451EXL), enhancing the functionality of the instrument. This software allows for data retrieval, user parameter selection and provides a virtual instrument display with audible (requires sound card) and visual alarm indication.

 

 

  • High sensitivity measurement of rate and dose simultaneously, with the capability to record peak rate
  • Auto-ranging and auto-zeroing
  • RS-232 communications interface with optional Windows-based Excel add-in for data logging
  • Ergonomic, anti-fatique handle with replaceable grip, wrist strap and tripod mount
  • Programmable flashing LCD display and audible alarm
  • Easily-accessible battery door (operated by 2 9-volt alkaline batteries) on the outside of the bottom case
  • Available with dose equivalent energy response (SI units)
  • CE Tested. Meets applicable standards
 

Accesorii standard

Models:
  • 451B-RYR Ion Chamber Survey Meter with Beta Slide and standard chamber 
  • 451B-DE-SI-RYR Ion Chamber Survey Meter with Beta Slide and dose equivalent chamber 
 

Alte produse FLUKE

ANALIZOR SECURITATE ELECTRICA FLUKE BIOMEDICAL DALE 601E

• Small, lightweight, self-contained portable instrument
• Master range meter delivers accurate measurment for each test
• Accurate test measurements with 4-wire Kelvin bridge
• Test method complies with AAMI load per ANSI/AAMI ES1-1993 or IEC601-1
• Leakage Current can be measured in Open/Closed Neutral, Normal/Reversed Polarity and Open/Closed Ground
• All Leakage Current measurements are displayed directly in µAmps
• Broad range of external measurements
• Five (5) Universal EKG Lead Connectors
• The DALE601E is designed for 230 V operation


ANALIZOR DEBIT FLUX GAZE FLUKE BIOMEDICAL VT PLUS HF

• Bi-directional flow, pressure, volume, and oxygen concentration, and pressure measurements
• Low- and high-pressure, and flow measurement capability
• Special HF mode-up to 900 BPM (15 Hz)
• RS-232 and printer ports
• Included Windows-compatible graphics software

 

ANALIZOR SECURITATE ELECTRICA FLUKE BIOMEDICAL 601 PRO

• EN60601-1, EN601010-1, and AAMI test loads (user selectable)
• Multiple enclosure-leakage points
• Multiple patient-applied-part types
• Power ON/OFF delay
• DC only for patient- and auxiliary-leakage tests
• User-programmable test sequences

 

TESTER CAMERE IONIZARE PRESURIZATE RADIATII GAMMA, RAZE X FLUKE BIOMEDICAL 451P

• High sensitivity µR measurements of rate and dose simultaneously, with the capability to record peak rate
• Ergonomic, anti-fatigue handle with replaceable grip, wrist strap and tripod mount
• Programmable flashing LCD display and audible alarm
• Easily-accessible battery door (operated by two 9-volt alkaline batteries) on the outside of the bottom case

 

ANALIZOR AUTOMAT SECURITATE ELECTRICA FLUKE BIOMEDICAL MEDTESTER 5000C

• Easy verification of biomedical equipment to manufacturer’s specifications
• Ten preprogrammed and five user-programmable electrical-safety-testing sequences
• Convenient transfer of equipment inventory and testing procedures from CMMS
• Automatic storage of detailed test results for printing or transfer to CMMS
• Compliant with ANSI/AAMI (1993) and NFPA-99 (2005) standards
• 20-A device testing with GFCI protection

 

RATMETRU DIGITAL UNIVERSAL MONITORIZARE RADIATII FLUKE BIOMEDICAL 942A/ 946A/ 952A

• User adjustable alarm set-points; retained indefinitely on power outage, keylock protection available
• Front panel pushbuttons for check source activation, high voltage indication, alarm setpoint indication, alarm acknowledge, and power ON/OFF
• Small front panel size allows dedicated display for each channel while minimizing panel space
• Ability to use existing cables when replacing most analog readouts

 

TESTER ENDOSCOAPE RIGIDE FLUKE BIOMEDICAL DALE301

• Incoming acceptance inspection performed
• Simple to use
• Lightweight and companct
• No light source or other accessories required


TESTER PORTABIL SECURITATE ELECTRICA FLUKE BIOMEDICAL 175

• Handheld portability (fitting in a briefcase)
• Self-switching 120/240 V operation
• Patient-lead-leakage testing
• 15 A and 20 A capabilities
• Digital accuracy
• Dual-lead testing

 

ANALIZOR ECHIPAMENTE ELECTRO-CHIRURGIE FLUKE BIOMEDICAL QA-ES

• Automatic power distribution measurement, including power, current, peak-to-peak voltage closed load only), and crest factor
• High-frequency leakage measurements with accuracy of ± 2 % of reading
• 128 internal user-selectable test loads from 10 O to 5200 O
• Ansur QA-ES software plug-in for automated test protocols
• RS-232 and Centronic-printer interface

 

TESTER DIGITAL SECURITATE ELECTRICA ECHIPAMENTE MEDICALE FLUKE BIOMEDICAL LT544

• Small, lightweight, self-contained portable instrument
• Universal Power Supply. Input voltage from 85 - 265 VAC
• Chassis Resistance measurements are made with a four-wire Kelvin bridge to eliminate errors due to cable length
• Test method complies with AAMI load per ANSI/AAMI ES1-1993