Brand: FLUKE BIOMEDICAL

Tester izolatie curenti LIM/ GFI Fluke Biomedical DALE2000

Cod: Fluke Biomedical DALE2000


 

Descriere

The Dale2000 is a stand alone battery operated instrument that checks the safety performance of isolated power and ground fault interrupted systems. This unique instrument has its own digital display that captures and holds the reading for 10 seconds after the circuit is tripped. Measurements are made by simply plugging the DALE2000 into a typical outlet of the system being tested, selecting the desired test via ganged push-buttons, and reading the results on the digital display.

The unit measures Line Voltage, ISO, LIM and GFI currents. A single knob is used in order to select the amount of current used.

 

 

  • Unique digital circuitry retains measurement
  • Direct reading of Line Voltage, LIM and GFI current
  • 9 volt battery operation
  • Universal voltages from 85 to 245 VAC, 50/60 Hz
  • Small, lightweight, very portable
  • Single range knob for Trip Point
  • Least expensive unit on the market today - best features
 

Alte produse FLUKE BIOMEDICAL

ANALIZOR SECURITATE ELECTRICA SPITALE SI CLINICI FLUKE BIOMEDICAL ESA620

• Compliance with multiple standards
• Three test loads
• Expanded leakage ranges through 10,000 µA
• AC only, DC only and True RMS leakage readings
• 100 % and 110 % mains voltage for mains on applied part (lead isolation) test
• 20 A equipment current

 

SIMULATOR PLAMAN PORTABIL DE PRECIZIE FLUKE BIOMEDICAL ACCU LUNG

• Small, lightweight and portable
• User-selectable compliance and resistance settings
• Calibrated accuracy for both resistance and compliance
• Complies with IEC standard for breathing- circuit connection
• Certified test lung for test system traceability to standards

 

TESTER ULTRASUNETE SECURITATE ELECTRICA FLUKE BIOMEDICAL ULT800

• Handheld
• Stand-alone operation
• Direct measurement of leakage current
• Battery-operated
• Independent of 120 V or 240 V systems
• Built-in self-test circuit
• Auto shut-off to conserve battery

 

ANALIZOR CONCENTRATIE OXIGEN O2 FLUKE BIOMEDICAL MAXO2 PLUS AE

• One-touch calibration, with reminder
• Long battery life (approx. 5,000 hrs)
• Impact resistant and drip proof
• External MAX-250E Oxygen Sensor

 

ANALIZOR INFUZII TESTARE POMPE FLUKE BIOMEDICAL IDA 4 PLUS

• Tests up to four infusion pumps simultaneously
• Compatible with virtually any type of infusion device
• Instantaneous and average flow measurement
• Occlusion pressure measurements to 45 psi
• Single- and dual-flow (piggyback) testing

 

TESTER MULTIFUNCTIONAL PARAMETRI PRESIUNE DIFERENTIALA, VACUUM, TEMPERATURA FLUKE BIOMEDICAL DPM4

• Palm size
• High accuracy
• Differential pressure, vacuum, and temperature measurements
• Multiple user-selectable units of measurement
• Simultaneous display of multiple parameter measurements
• Leak detection/leak-rate calculation
• RS232 for computer control

 

TESTER PRESIUNE GAZ/ LICHID ECHIPAMENTE MEDICALE FLUKE BIOMEDICAL DPM2PLUS

• Handheld
• Battery operated
• 1 % accuracy
• Five selectable scale ranges
• Voltage output to drive a recorder for assessing electronics of pressure measurement circuit
• Air or liquid measurement


TESTER CAMERE IONIZARE PRESURIZATE RADIATII GAMMA, RAZE X FLUKE BIOMEDICAL 451P

• High sensitivity µR measurements of rate and dose simultaneously, with the capability to record peak rate
• Ergonomic, anti-fatigue handle with replaceable grip, wrist strap and tripod mount
• Programmable flashing LCD display and audible alarm
• Easily-accessible battery door (operated by two 9-volt alkaline batteries) on the outside of the bottom case

 

TESTER PORTABIL SECURITATE ELECTRICA FLUKE BIOMEDICAL 175

• Handheld portability (fitting in a briefcase)
• Self-switching 120/240 V operation
• Patient-lead-leakage testing
• 15 A and 20 A capabilities
• Digital accuracy
• Dual-lead testing

 

ANALIZOR SECURITATE ELECTRICA FLUKE BIOMEDICAL 601 PRO

• EN60601-1, EN601010-1, and AAMI test loads (user selectable)
• Multiple enclosure-leakage points
• Multiple patient-applied-part types
• Power ON/OFF delay
• DC only for patient- and auxiliary-leakage tests
• User-programmable test sequences