Brand: FLUKE BIOMEDICAL

Ratmetru digital universal monitorizare radiatii Fluke Biomedical 942A/ 946A/ 952A

Cod: Fluke Biomedical 942A/ 946A/ 952A


 

Brosura produs PDF, 0.17 Mb

Descriere

Introduction

 

Universal Digital Ratemeters (UDR) are radiation monitoring instruments capable of being directly interfaced to pulse producing or low current producing detectors and displaying the radiation signal in various engineering units; (CPM, mR/h or µCi/cc). The UDRs are also capable of being interfaced to a computer system, via the digital communications port, and can be used as a local controller. Designed using military specification components, Fluke Biomedical’s family of UDRs achieves a high degree of reliability and are qualified for use in nuclear safety related applications. Thousands of UDRs have been installed around the world.

 

  • For use as area or process monitor readout
  • Compatible versions for all GM, ion chamber or scintillation detectors
  • High visibility LED display and status indicators
  • Analog outputs for recorder, remote display and computer
  • Fail safe DPDT relay contact outputs for warn, high and fail functions
  • Full seismic, environmental and EMI qualifications

 

 

 

Key Features

  • User adjustable alarm set-points; retained indefinitely on power outage, keylock protection available
  • Front panel pushbuttons for check source activation, high voltage indication, alarm setpoint indication, alarm acknowledge, and power ON/OFF
  • Small front panel size allows dedicated display for each channel while minimizing panel space
  • Ability to use existing cables when replacing most analog readouts
  • Plug-in connectors for field connections
  • Remote alarm acknowledge capability
  • Available with international units display
  • Ability to interface with "smart detectors"
  • Optional ribbon cable output adapter

 

 

Applications
The Model 942A-200 UDR can be used with all Model 943 Series Beta and Gamma Scintillation Detectors. The detector, when connected to the UDR, will comprise a single channel digital process monitoring channel. The Model 946A-200 UDR can be used with all Model 977 Series Wide Range Ion Chamber Detectors. The Model 956A-201 can be used with all Model 897A Series GM Detectors. Simulators are available for all models.

 

 

Specifications
The Universal Digital Ratemeters (UDR) feature a bright LED digital display and tricolor LED bar graph, both of which are easily read from a distance of 20 feet. The bar graph changes color with changes in alarm status, providing instantaneous recognition of relative levels and alarm status

 

Accesorii standard

Model Name

Description

942A-200

Detector Scintillation detectors, GM process monitors
Dynamic count range 0 to 107 CPM
Bargraph18 segments
High voltage output 450 to 1500 V @ 0.2 mA

946A-200

Detector Ion chambers
Dynamic range 0.1 mR/h to 107 mR/h
Bargraph 24 segments

956A-201

Detector GM detectors
Dynamic range Each detector model provides 5 decades. Readout covers 0.01 mR/h to 105 mR/h
Bargraph 24 segments
High voltage output 450 to 1500 V @ 0.2 mA

 

Alte produse FLUKE

TESTER PORTABIL SECURITATE ELECTRICA FLUKE BIOMEDICAL 175

• Ultra-portable (fitting in a briefcase)
• IEC601-1 and AAMI test loads
• Self-switching 120/240 V operation
• Point-to-point testing

 

TESTER PORTABIL SECURITATE ELECTRICA FLUKE BIOMEDICAL 175

• Handheld portability (fitting in a briefcase)
• Self-switching 120/240 V operation
• Patient-lead-leakage testing
• 15 A and 20 A capabilities
• Digital accuracy
• Dual-lead testing

 

TESTER CAMERE IONIZARE RADIATII BETA, GAMMA, RAZE X FLUKE BIOMEDICAL 451B

• High sensitivity measurement of rate and dose simultaneously, with the capability to record peak rate
• Auto-ranging and auto-zeroing
• RS-232 communications interface with optional Windows-based Excel add-in for data logging
• Ergonomic, anti-fatique handle with replaceable grip, wrist strap and tripod mount
• Programmable flashing LCD display and audible alarm

 

RATMETRU DIGITAL UNIVERSAL MONITORIZARE RADIATII FLUKE BIOMEDICAL 942A/ 946A/ 952A

• User adjustable alarm set-points; retained indefinitely on power outage, keylock protection available
• Front panel pushbuttons for check source activation, high voltage indication, alarm setpoint indication, alarm acknowledge, and power ON/OFF
• Small front panel size allows dedicated display for each channel while minimizing panel space
• Ability to use existing cables when replacing most analog readouts

 

TESTER CAMERE IONIZARE PRESURIZATE RADIATII GAMMA, RAZE X FLUKE BIOMEDICAL 451P

• High sensitivity µR measurements of rate and dose simultaneously, with the capability to record peak rate
• Ergonomic, anti-fatigue handle with replaceable grip, wrist strap and tripod mount
• Programmable flashing LCD display and audible alarm
• Easily-accessible battery door (operated by two 9-volt alkaline batteries) on the outside of the bottom case

 

DEFIBRILATOR STIMULARE IMPULSURI FLUKE BIOMEDICAL 6000D/ 7000DP

• Lown, Edmark, trapezoidal, biphasic and pulsed-biphasic defibrillation technology compatibility
• AED technology compatibility
• First-class measurement accuracy ± 1 % of reading + 0.1 J
• Intuitive user interface and backlight, easy-to-read display
• Portable, rugged, easy to carry

 

ANALIZOR SECURITATE ELECTRICA FLUKE BIOMEDICAL DALE 601E

• Small, lightweight, self-contained portable instrument
• Master range meter delivers accurate measurment for each test
• Accurate test measurements with 4-wire Kelvin bridge
• Test method complies with AAMI load per ANSI/AAMI ES1-1993 or IEC601-1
• Leakage Current can be measured in Open/Closed Neutral, Normal/Reversed Polarity and Open/Closed Ground
• All Leakage Current measurements are displayed directly in µAmps
• Broad range of external measurements
• Five (5) Universal EKG Lead Connectors
• The DALE601E is designed for 230 V operation


TESTER ULTRASUNETE SECURITATE ELECTRICA FLUKE BIOMEDICAL ULT800

• Handheld
• Stand-alone operation
• Direct measurement of leakage current
• Battery-operated
• Independent of 120 V or 240 V systems
• Built-in self-test circuit
• Auto shut-off to conserve battery

 

ANALIZOR AUTOMAT SECURITATE ELECTRICA FLUKE BIOMEDICAL MEDTESTER 5000C

• Easy verification of biomedical equipment to manufacturer’s specifications
• Ten preprogrammed and five user-programmable electrical-safety-testing sequences
• Convenient transfer of equipment inventory and testing procedures from CMMS
• Automatic storage of detailed test results for printing or transfer to CMMS
• Compliant with ANSI/AAMI (1993) and NFPA-99 (2005) standards
• 20-A device testing with GFCI protection

 

ANALIZOR CONCENTRATIE OXIGEN O2 FLUKE BIOMEDICAL MAXO2 PLUS AE

• One-touch calibration, with reminder
• Long battery life (approx. 5,000 hrs)
• Impact resistant and drip proof
• External MAX-250E Oxygen Sensor