Calibrator curent inalt clesti ampermetrici Meatest M151

Cod: Meatest M151


 

Brosura produs PDF, 0.38 Mb
 

Descriere

  • Current 8 mA … 120 A (AC/DC) 
  • Frequency 15 Hz … 1 kHz 
  • Simulated current and transconductance amplifier 
  • Built-in process multimeter
  • Output capability 8 Vpk
  • Interface bus GPIB and RS232 as standard
  • With current coil it can be used for calibration of clamp meters up to 3000 A

 

 

Description

M151 Current calibrator is accurate current source up to 120 A. It can be used for calibration of ammeters or as stable current source for precise measurement. The calibrator is equipped with a built-in multimeter that can be used for simulation of programmable transconductance or current amplifier.

 

The calibrator includes many other features which facilitate easy use. For example it is currently displayed uncertainty of the output signal, calibration and testing procedures etc. The concept of calibrator control and indication of its status is based on large TFT color display, which provides all necessary information. The calibrator is controlled by opening menus on the display and selection from menus. Frequently used functions are assigned direct-control keys. The calibrator comes with standard IEEE488 bus and RS-232 serial line, which allow the calibrator to be controlled from a PC.

 

The calibrator is supported in the automated calibration system Caliber.

 

 

Accesorii standard

  • Current Calibrator M151
  • Cable RS 232
  • User’s manual
  • Power supply cable
 

Optiuni recomandate

  • Option 151-25 25 turns current coil
  • IEEE488/IEEE488 GPIB cable 2m
  • Caliber SW for calibration of meters
 

Alte produse MEATEST

DECADA REZISTIVA CALIBRARE MEGOHMMETRE SI TESTERE IZOLATIE 5KV MEATEST M109R

• Calibration of insulation meters and megaohm meters
• Four decades
• Resistance range 1 MO - 12 GO
• Accuracy from 0.1 % to 1 %
• Maximum working voltage 5 kVdc
• Internal battery / power line adapter supplying
• RS232 bus

 

SIMULATOR RTD SENZORI TEMPERATURA PT100, PT200, PT500, PT1000, NI100, NI1000 MEATEST M612

• Calibration of temperature controllers
• Resistance range from 16 O to 10 kO
• Simulation of Pt and Ni sensors
• Accuracy +/- 0.02°C
• Temperature stability < 1 ppm/°C
• Simulation of cable resistances
• Interface RS 232 (IEEE488 optionally)

 

CALIBRATOR DE PUTERE SI ENERGIE ELECTRICA MEATEST M133

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" in the 3phase system 2 V to 1200 V
• DC/AC current 8 mA to 30 A / 5 V
• Power factor setting -1 to +1
• Harmonic, interharmonic distortion, modulation
• Frequency range 15 Hz to 1 kHz
• Simulated electric power to 8.4 kVA (420 kVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

DECADA REZISTIVA 10KV CALIBRARE MEGOHMMETRE SI TESTERE IZOLATIE MEATEST M191

• Total resistance range 10.00 k? to 1000.0 G?
• Resistance accuracy 0.1 to 5 %
• Test voltage range 10 000 VDC + 5%
• Test voltage accuracy indication 0.5 % + 10 V
• Test current indication 4 digit from 0.01 pA to 99.99 mADC
• Programmable high resistance decade box
• Short current verification
• Dielectric and absorption parameters simulation: polarization index (PI), dielectric absorption ratio (DAR) and polarization ratio (PR)
• High voltage capacitance in three fix points 10, 50, 100 nF
• HIPOT timer verification

 

DECADA REZISTENTE MARI CALIBRARE MEGOHMMETRE SI TESTERE IZOLATIE INALTA TENSIUNE 10KV MEATEST M191

• Total resistance range 10.00 k? to 1000.0 G?
• Resistance accuracy 0.1 to 5 %
• Test voltage range 10 000 VDC + 5%
• Test voltage accuracy indication 0.5 % + 10 V
• Test current indication 4 digit from 0.01 pA to 99.99 mADC
• Programmable high resistance decade box
• Short current verification
• Dielectric and absorption parameters simulation: polarization index (PI), dielectric absorption ratio (DAR) and polarization ratio (PR)
• High voltage capacitance in three fix points 10, 50, 100 nF
• HIPOT timer verification

 

REZISTOR ETALON DE PRECIZIE SI FRECVENTA INALTA CALIBRARE RLC-METRE MEATEST M530

• Resistance range 10 O to 1000 O
• Very low frequency dependency
• Applicable frequency range to 100 MHz
• Calibration of wide frequency range LCR meters

 

CALIBRATOR DE LABORATOR TENSIUNE, CURENT, REZISTENTA, CAPACITATE, FRECVENTA MEATEST M140

• 35ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 20 A
• Resistance up to 50 MO, capacitance up to 50 µF
• TC/RTD temperature sensors simulation
• Frequency output up to 20 MHz
• Electric power up to 240 V / 10 A
• Built-in process multimeter
• GPIB & RS232 interface

 

CALIBRATOR UNIVERSAL INALTA PRECIZIE MEATEST M142I

• 15ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 30 A
• TC temperature sensors simulation
• RS232 interface

 

CALIBRATOR MULTIFUNCTIONAL UNIVERSAL MEATEST M141

• 100ppm Accuracy
• DC/AC voltage up to 750 V
• DC/AC current up to 2 A
• Fix standard resistors from 10 O to 10 MO in decade values
• TC temperature sensors simulation
• Frequency output up to 20 MHz
• RS232 & GPIB (option) interface

 

DECADA CAPACITIVA CALIBRARE RLC-METRE MEATEST M520

• Designed for RCL meters calibration
• Range of capacitance from 100 pF to 12 mF
• Basic accuracy 0.25 %
• Maximal operating voltage 50 V
• Power supplying from internal battery or power line adapter
• Remote control RS-232