Calibrator universal multifunctional de laborator si precizie Meatest M143

Cod: Meatest M143


 

Brosura produs PDF, 0.44 Mb

Descriere

Features

 

  • Wide voltage range from 0 to 1000 V DC/AC with accuracy 0.01 %
  • Extended current range from 0 to 20 A DC/AC with accuracy 0.02 %
  • Extended current range to 1000 A using Meatest Option 140-50 Current coil for calibration of clamp ammeters
  • Sinusoidal & Non-sinusoidal waveforms
  • Fix standard resistors 10 O to 100 MO in decimal values with calibration accuracy 0.02 %
  • Thermocouple temperature sensor simulation R, S, B, J, T, E, K, N in range from 250 °C to 1850 °C
  • Cold junction automatic compensation using external Pt1000 sensor
  • RTD temperature sensor simulator as option
  • Power supply voltage 115/230V at 50/60 Hz
  • Interface RS 232, IEEE488 (optionally)
  • Small dimensions, overall weight 9 kg

 

Description

M143 Multifunction calibrator is cost saving solution for calibration of meters of electric quantities up to 1000 V and 20 A. It offers basic accuracy 0.01% in DC voltage needed for calibration of 3½ and 4½ digit multimeters. Resistance function is covered by eight fix resistors in range from 10 O to 100 MO. The calibrator offers TC temperature sensor simulation. It can be delivered optionally as well with RTD temperature sensor simulator. Thanks to its small dimensions and low weight the calibrator can be applied easily for field calibrations.
The calibrator main application field are production lines of panel meters, multimeters, transducers, measuring amplifiers, thermometers, and calibration laboratories where the calibrator can be applied as source of standard value for calibrations, verifications and adjustments of units under test.
Interface RS-232 and optionally GPIB interface bus enable automated operation in remote mode offering time saving automatic calibrations. Model M143 is fully compatible with Meatest calibration SW package CALIBER/WinQbase.

 

 

 

Accesorii standard

Basic accessories (included in delivery)

  •          Power line cord 1 pc
  •          User´s manual 1 pc
  •          Test report 1 pc
  •          Test cable 1000V/20A, 1m 2 pc
  •          Option 60 RTD Simulator Cable Adapter 1 pc (optionally) 
  •          Option 90 Pt1000 External Temperature Sensor 1 pc
  •          Cable RS232 1 pc
 

Optiuni recomandate

Option 140-50 Current coil with multiplying coefficient x25 and x50 is a usefull tool for calibration of clamp ammeters up to 1000 A at 50/60 Hz signal frequency.

 

External temperature sensor Pt1000 can be used for automatic compensation of cold junction of simulated thermocouple sensors.

 

Option 143-60 Cable adapter is designed for simulation of RTD temperature sensors. The adapter is connected to the front panel AUX connector. Platinum and nickel sensors temperature dependency is predefined in the calibrator.

 

Alte produse MEATEST

CALIBRATOR DE LABORATOR TENSIUNE, CURENT, REZISTENTA, CAPACITATE, FRECVENTA MEATEST M140

• 35ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 20 A
• Resistance up to 50 MO, capacitance up to 50 µF
• TC/RTD temperature sensors simulation
• Frequency output up to 20 MHz
• Electric power up to 240 V / 10 A
• Built-in process multimeter
• GPIB & RS232 interface

 

CALIBRATOR UNIVERSAL MULTIFUNCTIONAL DE LABORATOR SI PRECIZIE MEATEST M143

• Wide voltage range from 0 to 1000 V DC/AC with accuracy 0.01 %
• Extended current range from 0 to 20 A DC/AC with accuracy 0.02 %
• Extended current range to 1000 A for calibration of clamp ammeters
• Sinusoidal & Non-sinusoidal waveforms
• Fix standard resistors 10 O to 100 MO in decimal values with calibration accuracy 0.02 %
• Thermocouple temperature sensor simulation R, S, B, J, T, E, K, N in range from 250 °C to 1850 °C
• Cold junction automatic compensation using external Pt1000 sensor
• RTD temperature sensor simulator as option

 

CALIBRATOR MULTIFUNCTIONAL UNIVERSAL MEATEST M141

• 100ppm Accuracy
• DC/AC voltage up to 750 V
• DC/AC current up to 2 A
• Fix standard resistors from 10 O to 10 MO in decade values
• TC temperature sensors simulation
• Frequency output up to 20 MHz
• RS232 & GPIB (option) interface

 

DECADA REZISTIVA CALIBRARE MEGOHMMETRE SI TESTERE IZOLATIE 5KV MEATEST M109R

• Calibration of insulation meters and megaohm meters
• Four decades
• Resistance range 1 MO - 12 GO
• Accuracy from 0.1 % to 1 %
• Maximum working voltage 5 kVdc
• Internal battery / power line adapter supplying
• RS232 bus

 

DECADA REZISTENTE DE PRECIZIE MEATEST M622

• Resistance range 1.000 00 O - 1.200 000 MO
• Accuracy 0.005%
• Resolution from 10 µO
• Range of Pt sensor temperature simulation -200°C - +850°C
• Connection 2, 3, 4-wire
• Remote control RS232, optionally IEEE488
• Internal ACCU/power line adapter

 

CALIBRATOR CURENT INALT CLESTI AMPERMETRICI MEATEST M151

• Current 8 mA … 120 A (AC/DC)
• Frequency 15 Hz … 1 kHz
• Simulated current and transconductance amplifier
• Built-in process multimeter
• Output capability 8 Vpk
• Interface bus GPIB and RS232 as standard
• With current coil it can be used for calibration of clamp meters up to 3000 A

 

SARCINA REZISTIVA AC/DC CALIBRARE SURSE TENSIUNE, TRANSFORMATOARE MEATEST M192

• Resistance range from 15 O to 300 kO
• Maximal load 3kW, maximal voltage 250 Vrms
• Accuracy 0.1 %
• Temperature coefficient < 10 ppm/°C
• Interface RS - 232 (IEEE488 optionally)
• Table version (19" module as option)

 

CALIBRATOR DE PUTERE SI ENERGIE ELECTRICA MEATEST M133

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" in the 3phase system 2 V to 1200 V
• DC/AC current 8 mA to 30 A / 5 V
• Power factor setting -1 to +1
• Harmonic, interharmonic distortion, modulation
• Frequency range 15 Hz to 1 kHz
• Simulated electric power to 8.4 kVA (420 kVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

DECADA REZISTIVA PROGRAMABILA MEATEST M602

• Resistance range from 0.1 O to 10 MO with accuracy 0.02 %
• Temperature coefficient < 25 ppm/°C
• Max. load 2 W (120 V and 0.6 A)
• RTD (Pt, Ni) simulation with accuracy 0.2 °C
• Power supplying from power line adaptor or from internal battery
• Interface RS232 (IEEE488 optionally)
• Table version (19" module as option)

 

CALIBRATOR IMPEDANTA RLC-METRE: REZISTENTA, CAPACITATE, INDUCTANTA MEATEST M550

• Resistance standards from 0.1 O to 100 MO
• Capacitance standards from 10 pF to 100 µF
• Simulated inductance standards from 10 µH to 10 H
• Four pair coaxial terminal connection, four terminal connection, two terminal connection
• Calibration data from 20 Hz to 1 MHz
• Interface bus GPIB and RS232 as standard