Calibrator universal multifunctional de laborator si precizie Meatest M143

Cod: Meatest M143


 

Brosura produs PDF, 0.44 Mb

Descriere

Features

 

  • Wide voltage range from 0 to 1000 V DC/AC with accuracy 0.01 %
  • Extended current range from 0 to 20 A DC/AC with accuracy 0.02 %
  • Extended current range to 1000 A using Meatest Option 140-50 Current coil for calibration of clamp ammeters
  • Sinusoidal & Non-sinusoidal waveforms
  • Fix standard resistors 10 O to 100 MO in decimal values with calibration accuracy 0.02 %
  • Thermocouple temperature sensor simulation R, S, B, J, T, E, K, N in range from 250 °C to 1850 °C
  • Cold junction automatic compensation using external Pt1000 sensor
  • RTD temperature sensor simulator as option
  • Power supply voltage 115/230V at 50/60 Hz
  • Interface RS 232, IEEE488 (optionally)
  • Small dimensions, overall weight 9 kg

 

Description

M143 Multifunction calibrator is cost saving solution for calibration of meters of electric quantities up to 1000 V and 20 A. It offers basic accuracy 0.01% in DC voltage needed for calibration of 3½ and 4½ digit multimeters. Resistance function is covered by eight fix resistors in range from 10 O to 100 MO. The calibrator offers TC temperature sensor simulation. It can be delivered optionally as well with RTD temperature sensor simulator. Thanks to its small dimensions and low weight the calibrator can be applied easily for field calibrations.
The calibrator main application field are production lines of panel meters, multimeters, transducers, measuring amplifiers, thermometers, and calibration laboratories where the calibrator can be applied as source of standard value for calibrations, verifications and adjustments of units under test.
Interface RS-232 and optionally GPIB interface bus enable automated operation in remote mode offering time saving automatic calibrations. Model M143 is fully compatible with Meatest calibration SW package CALIBER/WinQbase.

 

 

 

Accesorii standard

Basic accessories (included in delivery)

  •          Power line cord 1 pc
  •          Userīs manual 1 pc
  •          Test report 1 pc
  •          Test cable 1000V/20A, 1m 2 pc
  •          Option 60 RTD Simulator Cable Adapter 1 pc (optionally) 
  •          Option 90 Pt1000 External Temperature Sensor 1 pc
  •          Cable RS232 1 pc
 

Optiuni recomandate

Option 140-50 Current coil with multiplying coefficient x25 and x50 is a usefull tool for calibration of clamp ammeters up to 1000 A at 50/60 Hz signal frequency.

 

External temperature sensor Pt1000 can be used for automatic compensation of cold junction of simulated thermocouple sensors.

 

Option 143-60 Cable adapter is designed for simulation of RTD temperature sensors. The adapter is connected to the front panel AUX connector. Platinum and nickel sensors temperature dependency is predefined in the calibrator.

 

Alte produse MEATEST

CALIBRATOR IMPEDANTA RLC-METRE: REZISTENTA, CAPACITATE, INDUCTANTA MEATEST M550

• Resistance standards from 0.1 O to 100 MO
• Capacitance standards from 10 pF to 100 µF
• Simulated inductance standards from 10 µH to 10 H
• Four pair coaxial terminal connection, four terminal connection, two terminal connection
• Calibration data from 20 Hz to 1 MHz
• Interface bus GPIB and RS232 as standard

 

DECADA CAPACITIVA CALIBRARE RLC-METRE MEATEST M520

• Designed for RCL meters calibration
• Range of capacitance from 100 pF to 12 mF
• Basic accuracy 0.25 %
• Maximal operating voltage 50 V
• Power supplying from internal battery or power line adapter
• Remote control RS-232

 

CALIBRATOR UNIVERSAL INALTA PRECIZIE MEATEST M142I

• 15ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 30 A
• TC temperature sensors simulation
• RS232 interface

 

CALIBRATOR DE PUTERE SI ENERGIE ELECTRICA MEATEST M133

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" in the 3phase system 2 V to 1200 V
• DC/AC current 8 mA to 30 A / 5 V
• Power factor setting -1 to +1
• Harmonic, interharmonic distortion, modulation
• Frequency range 15 Hz to 1 kHz
• Simulated electric power to 8.4 kVA (420 kVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

CALIBRATOR IMPEDANTA RLC-METRE: REZISTENTA, CAPACITATE, INDUCTANTA MEATEST M550

• Resistance standards from 0.1 O to 100 MO
• Capacitance standards from 10 pF to 100 µF
• Simulated inductance standards from 10 µH to 10 H
• Four pair coaxial terminal connection, four terminal connection, two terminal connection
• Calibration data from 20 Hz to 1 MHz
• Interface bus GPIB and RS232 as standard

 

CALIBRATOR DE LABORATOR TENSIUNE, CURENT, REZISTENTA, CAPACITATE, FRECVENTA MEATEST M140

• 35ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 20 A
• Resistance up to 50 MO, capacitance up to 50 µF
• TC/RTD temperature sensors simulation
• Frequency output up to 20 MHz
• Electric power up to 240 V / 10 A
• Built-in process multimeter
• GPIB & RS232 interface

 

DECADA REZISTIVA CALIBRARE MEGOHMMETRE SI TESTERE IZOLATIE 5KV MEATEST M109R

• Calibration of insulation meters and megaohm meters
• Four decades
• Resistance range 1 MO - 12 GO
• Accuracy from 0.1 % to 1 %
• Maximum working voltage 5 kVdc
• Internal battery / power line adapter supplying
• RS232 bus

 

DECADA REZISTIVA 10KV CALIBRARE MEGOHMMETRE SI TESTERE IZOLATIE MEATEST M191

• Total resistance range 10.00 k? to 1000.0 G?
• Resistance accuracy 0.1 to 5 %
• Test voltage range 10 000 VDC + 5%
• Test voltage accuracy indication 0.5 % + 10 V
• Test current indication 4 digit from 0.01 pA to 99.99 mADC
• Programmable high resistance decade box
• Short current verification
• Dielectric and absorption parameters simulation: polarization index (PI), dielectric absorption ratio (DAR) and polarization ratio (PR)
• High voltage capacitance in three fix points 10, 50, 100 nF
• HIPOT timer verification

 

CALIBRATOR PUTERE SI ENERGIE ELECTRICA TRIFAZICA MEATEST M133CI

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" 2 V to 1200 V
• DC/AC current 8 mA to 30 A / 5 V
• DC/AC current 90 A in one phase configuration
• Power factor setting -1 to +1
• Floating current outputs to 450 Vpk
• Frequency range 15 Hz to 1 kHz
• Simulated electric power to 54 kVA (2.7 MVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

REZISTENTA CAPACITATE INDUCTANTA STANDARD PENTRU CALIBRARE RLC-METRE

• Resistance Capacitance Inductance standards
• Traceability of electric quantities
• Calibration of meters
• Calibration uncertainty 0.005 %
• Low time constant
• Three/four terminal or four pair terminal connection