• ALL-IN-ONE tool for electrical installation testing • compliance with the national and international standards (IEC 60364-6, NF C 15-100, VDE 100, XP C 16-600... • design, ergonomics, simplicity, rapidity and accuracy • Suitable for all types of neutral systems (TT, TN, IT) • large backlit graphic screen
• insulation: up to 1,000MO (1 cal.) at 500V DC • AC voltage: 0 to 600V • continuity: -10? to +10? (I=200mA) • automatic testing of absence of voltage by direct measurement • single input on two colour-coded terminals
• Direct, safe connection to installation mains • Automatic installation voltage and frequency measurement • Tests standard, selective, A and AC RCDs • 5 fixed calibres 10/30/100/300/500mA + 1 calibre adjustable from 6 to 650mA • Checks RCD trips / trip time measurement (pulse or ramp mode) and exact trip current (ramp mode)
• calculate the ratios • NiMH battery life of up to 10 hours • Automatic calibration and balancing • Low-voltage test • Digital display � display of ratios, winding direction - % deviation • Degauss function
• dielectric test: standard measurement modes (Un from 100 to 5,000V with Ilim 500mA) and programmed modes (t1, t2, t3, U1, U2) • continuity: up to 100O with 0.1 < ITEST < 25A • voltage drop: up to 100V (Itest > 10A) • insulation resistance: up to 1GO at 250/500VDC and 1,000VDC • measurement of internal and external discharge time (at the plug) • leakage current: operating and residual up to 20mA, contact up to 2mA • functional testing: voltage, current, frequency and power
• automatic installation status test immediately after connection • measurement of voltage (10 to 440V AC/DC) and frequency (15.3 to 450Hz) • installation insulation measurement at 500V • standard earth connection resistance measurement (1 stake + loop method) • PE conductor continuity test • measurement of internal loops • testing of RCDs up to 500mA (exact tripping time and current) • phase rotation testing
• Measurements in compliance with the IEC 60204 Ed.5 / VDE701/702 / IEC 61439 (IEC 60439) standards • 200 mA and 10 A continuity measurements • Insulation resistance at 250 VDC and 500 VDC • Dielectric test at 1,000 V / 1,890 V / 2,500 V • Leakage current measurement by substitution method • Differential leakage current • Contact leakage current • Mains power-lead polarity test
• Wide measurement range from 10 kohm to 30 Tohm • Fixed or programmable test voltage from 40V to 15 kV • 5mA max. charging current • Large backlit LCD screen with digital display, bargraph and R(t)+u(t), i(t) and i(u) graphs • Automatic ratio calculation: DAR / PI / DD / DR (ppm/V) • Multiple test modes: voltage ramp and step with "burning", "early break" and "I-limit" modes
• measurement range: 10k? to 10T?! • 4 fixed test voltages: 500 / 1,000 / 2,500 and 5,000V • adjustable test voltage position: 40 to 5,100V in 10V or 100V increments • step voltage mode: R(Utest) measurement curve viewed on the screen and gradient calculated automatically in ppm/V • DAR, PI and DD quality ratios calculated automatically • programmable test length and R(t) measurement curve
• Wide measurement range from 10 kohm to 25 Tohm • Fixed or programmable test voltage from 40V to 10 kV • 5mA max charging current • Large backlit LCD screen with digital display, bargraph and R(t)+u(t), i(t) and i(u) graphs • Automatic ratio calculation: DAR / PI / DD / DR (ppm/V)
• wide range from 30k? to 10T? ! • 4 fixed test voltages: 500 / 1,000 / 2500 and 5,000V • programmable test voltage position: from 40 to 5,100V in increments of 10V or 100V • giant backlit LCD screen with digital display + bargraph • qualitative analysis of insulation: automatic calculation of DAR, PI and DD (dielectric discharge) ratios • plotting of the R(t) curve
• wide range from 30k? to 10T? ! • 4 fixed test voltages: 500/1,000/2,500 and 5,000V • programmable test voltage position: from 40 to 5,100V in increments of 10V or 100V • giant backlit LCD screen with digital display + bargraph • qualitative analysis: automatic calculation of DAR, PI and DD
• Adjustable test voltage: 40 V to 5,100 V in 10 or 100 V increments • 500 V: 10 kO to 2 TO • 1,000 V: 10 kO to 4 TO • 2,500 V: 10 kO to 10 TO • 5,000 V: 10 kO to 10 TO
• insulation: up to 4TO (5 cal.) at 50/100/250/500 and 1,000V DC • automatic calculation of insulation quality ratios: DAR and PI • programmable test period and plottingof the R(t) curve • automatic indication of voltage before and after measurement: 1 to 1,000V AC/DC • resistance: 0.01O to 400kO • continuity: 0.01O to +40O (audible beep and lead compensation )
• insulation: up to 4TO (5 cal.) at 50/100/250/500 and 1,000V DC • automatic calculation of insulation quality ratios: DAR and PI • programmable test period and plotting of the R(t) curve (automatic memorisation of 20 samples) • automatic indication of voltage before and after measurement: 1 to 1000V AC/DC • resistance: from 0.01O to 400kO • continuity: 0.01O to +40O (audible beep and lead compensation) • automatic measurement capacity after each insulation measurement: 0.005 to 4.999 �F
• insulation: up to 2G? at 250V, 500V and 1,000V DC • voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V) • continuity: -20? to +20? (audible beep and compensation of leads) • resistance: 0 to 400k? • giant 4,000-count display + bargraph
• insulation: up to 2G? at 500V and 1,000V DC • voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V) • continuity: -20? to +20? (audible beep and compensation of leads) • resistance: 0 to 400k? • giant 4,000-count display + bargraph
• insulation: up to 400MO at 50V and 100V • AC voltage measurement: 0 to 400V • voltage indication before measurement of insulation: 0 to 600V AC/DC (blocking if U>25V) • resistance: 0 to 40kO • capacity: 0 to 4000nF • current: 0 to 400mA AC/DC
• insulation: up to 2G? at 250V and 500V DC • voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V) • continuity: -20? to +20? (audible beep) • giant 400-count display + bargraph (simultaneous reading of measurement and analogue variance) • back stand for use on a table or on the ground • long battery life: 6 x 1.5V batteries
• insulation: up to 20G? at 50V, 100V, 250V and 500V • voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V) • resistance: 0 to 400kO • giant 4,000-count display + bargraph • backlit display • programmable alarms
• insulation: up to 1,000MO (1 cal.) at 500V and 1,000V DC • AC voltage: 0 to 600V • resistance: 0 to 1,000O • continuity: -10O to +10O (I=200mA) • automatic testing of voltage absence by direct measurement