Multimetru digital portabil inalta rezolutie Metrel MD 9050

Cod: Metrel MD9050 MD-9050


 

Brosura produs PDF, 0.25 Mb
 

Descriere

The MD 9050 ranks among the best multimeters on the market. High resolution and accuracy, 2-line LCD display, fast data acquisition and transfer (via optical interface), CAT IV/1000 V, TRMS current and voltage measurement, non-contact voltage detector, conductance measurement, etc.

 

TEST FUNCTIONS

  • TRMS DC and AC voltage up to 1000 V
  • TRMS DC and AC current measurement up to 10 A
  • Diode test
  • Resistance measurement
  • Continuity test
  • Frequency measurement
  • Capacitance measurement
  • Temperature measurement

 

DATA

Dimensions (w x h x l): 103 x 64,5 x 208 mm

Mass (without accessories): 635 g

 

Accesorii standard

MD 9050 Standard set

  • Multimeter MD 9050 with rubber holster
  • 2 test leads
  • Thermocouple probe, type K
  • Battery
  • User manual
  • Warranty

 

 

Alte produse METREL

TESTER REZISTENTA PRIZA DE PAMANT METREL MI 3123 SMARTEC

• Supports all types of earthing resistance measurements:
• - Standard earthing resistance measurement with spikes
• - Selective earthing resistance test with one current clamp
• - Selective (contactless) earthing resistance with two current clamps
• - Specific earth resistance measurement
• Leakage current tests with current clamps
• Load current tests with current clamps
• High accuracy, very high immunity against external noise
• Preprogrammed limits

 

MULTIMETRU PORTABIL PENTRU ELECTRICIAN DEPANARI ELECTRICE SI ELETRICITATE METREL MD 9015

• 1000V DC, 750V AC voltage measurement;
• 10A AC, DC current measurement;
• 250O..25MO Resistance measurement;
• 2500nF..25mF Capacitance measurement;
• 30Hz..200kHz Frequency Measurement
• Temperature measurement

 

TESTER REZISTENTA IZOLATIE LA 2500V INSTALATII ELECTRICE METREL MI 3102H CL EUROTEST XE 2.5KV

• Insulation resistance with up to 2500V DC voltage
• PI, DAR calculation
• Continuity of PE conductors with 200 mA test current with polarity change
• Continuity of PE conductors with 7 mA test current (continuous measurement) without RCD tripping
• Line impedance
• Loop impedance
• Loop impedance with Trip Lock RCD function
• TRMS voltage and frequency

 

VOLTMETRU TENSIUNE SI CONTINUITATE METREL MD 1150

• Voltage testing up to 1000 V
• Automatic AC/DC recognition
• Continuity testing up to 2000 ?
• Phase & Rotating Field Test RCD fault test
• Diode Test
• Auto Power Off
• Data Hold
• LCD display with backlight

 

MICROHMMETRU REZISTENTE MICI 10A METREL MI 3250

• Bidirectional resistance measurement from 0,1 µO up to 2000 O
• test current up to 10 A
• Highly efficient 10 A current source generates 10 A into 200 mO load for 15 min without overheating
• High overvoltage protection (CAT IV / 300 V)
• Custom limits can be set for PASS / FAIL evaluation of test result.
• 50 Hz / 60 Hz ripple detection and rejection.
• Instrument can be powered from mains or internal rechargeable battery.
• Up to 1000 test results with timestamp can be stored in internal memory.
• PC SW HVLink PRO enables downloading, review, analyses and printing of test results.

 

TESTER SECURITATE ECHIPAMENTE ELECTRICE CF. STANDARD IEC EN VDE METREL MI 2142 ALPHA PAT

• Functional and visual inspection;
• Earth bond resistance;
• Insulation resistance;
• Substitute leakage current;
• Differential leakage current test;
• Touch leakage test;
• IEC cord polarity test;

 

PLATFORMA EDUCATIONALA PENTRU STUDIUL INSTALATIILOR INDUSTRIALE SI REZIDENTIALE DE JOASA TENSIUNE METREL MA 2067 DEMO

• Complete representation of a real low voltage installation in industrial and residential areas
• sockets,
• electrical loads,
• lightning,
• earthing systems for TT, TN and IT types of installations.
• 65 different measurements according to IEC/EN61557 are supported.
• Fault situation simulation switches can generate 19 errors or combination of these
• Detailed instruction manual with profound explanation of all typical measurements.

 

MICROOHMMETRU TRANSFORMATOR PRECIZIE CURENT 100A METREL MI 3252

• Resistance measurement: wide measuring range (1 nO ... 20 O)
• adjustable test current (100 mA ... 100 A)
• Voltage drop measurement
• Bar graph: on screen resistance bar graph
• protection level (CAT IV, 50 V)
• Portable
• High protection degree: IP 64.
• Accurate: 1 nO best resolution with 0.25% accuracy
• Custom limits: the limits can be set for PASS or FAIL evaluation of test result.
• Battery powered
• Downloadable: downloads test results via RS232 or USB cable directly to the PC with the help of the software.

 

ANALIZOR FOTOVOLTAIC CURBA I-V SI SECURITATE INSTALATII ELECTRICE SOLARE METREL MI 3108 EUROTEST PV

• Measurements on DC side of PV installation:
• Voltage, current, power, energy;
• Uoc (Open Circuit Voltage) and Isc (Short Circuit Current);
• I - U curve of PV modules and strings;
• Irradiance;
• Module temperature.
• Measurements on AC side of PV installation (power quality):
• Voltage, current, frequency, power, PF, energy, harmonics;
• Efficiency of PV module, inverter, PV system calculation.

 

MEGOHMMETRU REZISTENTA DE IZOLATIE 1000V METREL MI-2088

• Measurements on earthing and lightning protection systems include: standard 4-wire method, standard 4-wire method with current clamps and 2-clamp method without junctions disassembling.
• Specific earth resistance (soil resistance).
• DC insulation resistance measurement with test voltages from 50 V up to 1000 V in 10 V steps. Measuring range up to 30 GOhm.