Brand: TDK

Antena biconica de mare putere 20..300 MHz TDK HBA-2030

Cod: TDK HBA-2030


 

Brosura produs PDF, 0.1 Mb

Descriere

  • Frequency Range: 20 MHz to 300 MHz
  • VSWR: 2.5:1 average
  • Polarization: Linear
  • Power Handling: 3500 W continuous
  • Feedpoint Impedance: 50 ohms nominal
  • Designed primarily for immunity testing, but the balance and pattern of the HBA-2030 easily meet the requirements for emissions measurements
  • Improved balun provides superior patterns and balance
  • Improved cage design provides enhanced low frequency performance and mode-free operation to 300 MHz and higher
  • Moderate power handling capability accommodates a wide range of immunity testing applications
 

Alte produse TDK

CAMERA ANECOICA COMPACTA FULLY COMPLIANT 26 MHZ..1 GHZ TDK CAC-S™ 2601

• Dimensions: 7.0 m long x 3.0 m wide x 3.0 m high
• Absorbers: X-131 Fully lined double layer ferrite
• Radiated emissions: Compliance with EN 50147-2
• Radiated immunity: Compliance with IEC 1000-4-3
• EMI frequency range: 30 MHz - 1 GHz
• EMS frequency range: 26 MHz - 1 GHz
• Radiated emissions: Pre-compliance with EN 50147-2, ANSI C63.4, CISPR 22
• Radiated immunity: Full compliance with IEC 1000-4-3

 

SISTEM INTEGRAT MONITORIZARE ECHIPAMENT TESTAT TDK EUT-TS

• Best-in-Class Test Instruments
• Fully Integrated Hardware and Software
• Remote Control of Switches, Positioning Devices, and LISNs
• Automated, Semi-automated, and Manual Testing
• Ergonomically Designed Test Consoles and Racks
• High Quality System Cabling and Connectors
• Quality Workmanship
• On-Site Training
• Comprehensive Warranty

 

ANTENA DIPOL LOG-PERIODICA BANDA LARGA 80 MHZ..1 GHZ TDK LPDA-0801

• Frequency Range: 80 MHz to 1 GHz
• Gain: 5 - 6 dBi
• VSWR: 1.5:1 average
• Polarization: Linear
• Power Handling: 2.5 kW (continuous)
• Impedance: 50 Ohms nominal

 

CAMERA ANECOICA FULLY COMPLIANT TESTE 3M CISPR 26 MHZ..18 GHZ TDK

• Dimensions: 9.0 m long x 6.0 m wide x 5.4 m high (29'-6" L x 19'-8" W x 17'-8" H)
• Absorbers: IB-015 fully lined double layer ferrite tile IP-045C partially lined absorber
• EMI frequency range: 30 MHz - 18 GHz
• EMS frequency range: 26 MHz - 18 GHz
• Radiated emissions: Full compliance with ANSI C63.4, EN 50147-2, CISPR 22
• Radiated immunity: Full compliance with IEC 1000-4-3

 

ANTENA HORN DE BANDA LARGA 1..18 GHZ TDK HRN-0118

• Frequency Range: 1-18 GHz
• VSWR: <1.5:1 average
• Polarization: Linear
• Power Handling: 500W
• Feedpoint Impedance: 50 ohms (nominal

 

CAMERA ANECOICA COMPACTA COMPLET CONFORMA STANDARDE EMC 26 MHZ..18 GHZ TDK CAC-S™ 2618

• Dimensions: 7.5 m long x 3.0 m wide x 3.0 m high (24'-7" L x 9'-10" W x 9'-10" H)
• Absorbers: X-131 Fully lined double layer ferrite
• EMI frequency range: 30 MHz - 18 GHz
• EMS frequency range: 26 MHz - 18 GHz
• Radiated emissions: Pre-compliance with EN 50147-2, ANSI C63.4, CISPR 22
• Radiated immunity: Full compliance with IEC 1000-4-3

 

ANTENA EMC DE MARE PUTERE 25..100 MHZ TDK HPBA-2510

• Frequency Range: 25 MHz to 100 MHz
• VSWR: 5.8:1 max, 2.5:1 typical
• Polarization: Linear
• Power Handling: 3500 W maximum (10,000 W model available)
• Improved impedance matching

 

LINIE TRANSMISIE GENERARE CAMP ELECTRIC SI MAGNETIC CONTROLAT DE MARE PUTERE 10 KHZ..100 MZ TDK EFG-02

• 10kHz - 100 MHz operating range
• High power field generator
• Up to 500 V/m RSM
• Low VSWR
• Adjustable height for optimizing performance

 

MATERIALE ABSORBTIE UNDE RADIO EMISE IN BANDA LARGA TDK

• Wide Band Cascade Absorber IP-045C
• Wide Band Cascade Absorber IP-090BL
• Wide Band Cascade Absorber IP-130BL
• Oblique Incident Absorber IS-080S
• Ferrite Absorber IB-017
• Ferrite Absorber IB-017 & Dielectric
• Ferrite Tile Floor Plate FP-2
• Ferrite Tile Floor Plate FP-2 & IP-045C Absorber

 

CAMERA ANECOICA FULLY COMPLIANT TESTE 10M CISPR 26 MHZ..18 GHZ TDK

• Dimensions: 18.0 m long x 12.0 m wide x 8.4 m high (59' L x 39'-4" W x 27'-6" H)
• Absorbers: IB-015 fully lined ferrite IP-090BL fully lined absorber
• EMI frequency range: 30 MHz - 40 GHz
• EMS frequency range: 26 MHz - 18 GHz
• Radiated emissions: Full compliance with ANSI C63.4, EN 50147-2, CISPR 22
• Radiated immunity: Full compliance with IEC 1000-4-3