Ideal for tests on telephone lines or electronic equipment, the C.A 6533 megohmmeter measures insulation at 50V, 100V, 250V and 500V, as well as resistance. It indicates the AC/DC voltage before each measurement.

 

  • insulation: up to 20G? at 50V, 100V, 250V and 500V
  • voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
  • resistance: 0 to 400kO
  • giant 4,000-count display + bargraph (simultaneous reading of the measurement and analogue variation)
  • backlit display
  • programmable alarms
  • DREL function for testing for the presence of transmission frame or measurement of the difference in resistance between 2 wires of a pair
  • remote control probe (option)
  • back stand for use on a table or on the ground
  • long battery life: 6 x 1.5V batteries
  • Measurements in compliance with IEC 61557, NF C 15-100, VDE 0413
  • electrical safety: IEC 1010 300V Cat. III

 

 

 

Standard accessories

C.A 6531...................P01140804B

C.A 6533...................P01140805

 

½ 1 "hands-free" carrying case

½ 1 pair of 1.5 m leads, red + black

(the leads on C.A 6533 are guarded)

½ 1 red croc-clip

½ 1 black test probe

½ 2 wire grips, red + black

½ 6 LR6 batteries

½ 1 set of operating instructions.

* + 1 blue 1.5 m lead and 1 blue croc-clip for model C.A 6533

 

More products CHAUVIN ARNOUX

EARTH AND LOOP RESISTANCE TESTER CHAUVIN ARNOUX CA6456

• loop resistance and impedance: L-N, L-L, and L-PE from 0.20 to 4 kO
• short-circuit current displayed up to 40 kA by calculation (Uref/ZL-PE)
• clamp measurement of current and leakage current (option)
• Cat. III, 600V

 

EARTHING RESISTANCE TESTER CHAUVIN ARNOUX CA6470N TERCA3

• extensive measurement ranges: 0.001? to 100 k?
• adjustment of the measurement frequency between 41 Hz and 512 Hz
• 10 times greater accuracy due to its 4-pole measurement method
• measuring soil resistivity
• calculate r automatically by the Wenner or Schlumberger methods

 

DIGITAL INSULATION MEGOHMMETER 100V CHAUVIN ARNOUX CA6531

• insulation: up to 400MO at 50V and 100V
• AC voltage measurement: 0 to 400V
• voltage indication before measurement of insulation: 0 to 600V AC/DC (blocking if U>25V)
• resistance: 0 to 40kO
• capacity: 0 to 4000nF
• current: 0 to 400mA AC/DC


INSULATION MEGOHMETER 5KV CHAUVIN ARNOUX CA6505

• Adjustable test voltage: 40 V to 5,100 V in 10 or 100 V increments
• 500 V: 10 kO to 2 TO
• 1,000 V: 10 kO to 4 TO
• 2,500 V: 10 kO to 10 TO
• 5,000 V: 10 kO to 10 TO

 

EARTH GROUND RESISTANCE TESTER ON PYLONS CHAUVIN ARNOUX CA6472

• 5 tools in 1 with this tester
• extensive measurement ranges: 0.001?to 100 k?
• analysing the frequency behaviour of the earthing systems (from 41 Hz to 5 kHz)
• high-level, expert calculation capabilities
• IP 53 leakproofing

 

MULTIFUNCTION ELECTRICAL INSTALLATION TESTER CHAUVIN ARNOUX CA6116

• ALL-IN-ONE tool for electrical installation testing
• compliance with the national and international standards (IEC 60364-6, NF C 15-100, VDE 100, XP C 16-600...
• design, ergonomics, simplicity, rapidity and accuracy
• Suitable for all types of neutral systems (TT, TN, IT)
• large backlit graphic screen

 

EARTH GROUNDING RESISTANCE TESTER CHAUVIN ARNOUX CA6462

• 3-in-1 tester: resistivity, earth, coupling
• measurement range: 0.00 to 2,000? (3 automatic calibres)
• change from 4-wire method to 3-wire method thanks to 1 removable captive bar between E and ES
• 3 fault presence indicators to validate measurement
• measurement frequency: 128Hz

 

MEGOHMMETER 15KV CHAUVIN ARNOUX CA6555

• Wide measurement range from 10 kohm to 30 Tohm
• Fixed or programmable test voltage from 40V to 15 kV
• 5mA max. charging current
• Large backlit LCD screen with digital display, bargraph and R(t)+u(t), i(t) and i(u) graphs
• Automatic ratio calculation: DAR / PI / DD / DR (ppm/V)
• Multiple test modes: voltage ramp and step with "burning", "early break" and "I-limit" modes

 

EARTH RESISTANCE DIGITAL TESTER CHAUVIN ARNOUX CA6423

• earth resistance: 0.00 to 2,000O (3 cal.)
• 3 fault presence indicators to validate the measurement
• measurement frequency: 128Hz
• connection of rods to colour-coded terminals
• a removable captive connection strip between H and S for measurement of 2-wire resistance
• large 2,000-count digital display with 18mm digits: excellent readability


DIGITAL INSULATION MEGOHMMETER 500V CHAUVIN ARNOUX CA6521

• insulation: up to 2G? at 250V and 500V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep)
• giant 400-count display + bargraph (simultaneous reading of measurement and analogue variance)
• back stand for use on a table or on the ground
• long battery life: 6 x 1.5V batteries