Digital Insulation Megohmmeter 500V Chauvin Arnoux CA6533

Code: Chauvin Arnoux CA6533


 

Description

Ideal for tests on telephone lines or electronic equipment, the C.A 6533 megohmmeter measures insulation at 50V, 100V, 250V and 500V, as well as resistance. It indicates the AC/DC voltage before each measurement.

 

  • insulation: up to 20G? at 50V, 100V, 250V and 500V
  • voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
  • resistance: 0 to 400kO
  • giant 4,000-count display + bargraph (simultaneous reading of the measurement and analogue variation)
  • backlit display
  • programmable alarms
  • DREL function for testing for the presence of transmission frame or measurement of the difference in resistance between 2 wires of a pair
  • remote control probe (option)
  • back stand for use on a table or on the ground
  • long battery life: 6 x 1.5V batteries
  • Measurements in compliance with IEC 61557, NF C 15-100, VDE 0413
  • electrical safety: IEC 1010 300V Cat. III

 

 

 

Standard accessories

C.A 6531...................P01140804B

C.A 6533...................P01140805

 

½ 1 "hands-free" carrying case

½ 1 pair of 1.5 m leads, red + black

(the leads on C.A 6533 are guarded)

½ 1 red croc-clip

½ 1 black test probe

½ 2 wire grips, red + black

½ 6 LR6 batteries

½ 1 set of operating instructions.

* + 1 blue 1.5 m lead and 1 blue croc-clip for model C.A 6533

 

More products CHAUVIN ARNOUX

EARTHING RESISTANCE TESTER CHAUVIN ARNOUX CA6471

• extensive measurement ranges: 0.001? to 100 k?
• adjustment of the measurement frequency between 41 Hz and 512 Hz
• 10 times greater accuracy due to its 4-pole measurement method
• measuring soil resistivity
• calculate r automatically by the Wenner or Schlumberger methods
• Ergonomic, comprehensive and accurate

 

DIGITAL INSULATION MEGOHMMETER 5KV CHAUVIN ARNOUX CA6549

• measurement range: 10k? to 10T?!
• 4 fixed test voltages: 500 / 1,000 / 2,500 and 5,000V
• adjustable test voltage position: 40 to 5,100V in 10V or 100V increments
• step voltage mode: R(Utest) measurement curve viewed on the screen and gradient calculated automatically in ppm/V
• DAR, PI and DD quality ratios calculated automatically
• programmable test length and R(t) measurement curve

 

RCD TESTER CHAUVIN ARNOUX CA6030

• Direct, safe connection to installation mains
• Automatic installation voltage and frequency measurement
• Tests standard, selective, A and AC RCDs
• 5 fixed calibres 10/30/100/300/500mA + 1 calibre adjustable from 6 to 650mA
• Checks RCD trips / trip time measurement (pulse or ramp mode) and exact trip current (ramp mode)

 

EARTH GROUND RESISTANCE TESTER CHAUVIN ARNOUX CA6460

• 3-in-1 tester: resistivity, earth, coupling
• measurement range: 0.00 to 2,000? (3 automatic calibres)
• change from 4-wire method to 3-wire method thanks to 1 removable captive bar between E and ES
• 3 fault presence indicators to validate measurement
• measurement frequency: 128Hz

 

TRANFORMER RATIO TESTER CHAUVIN ARNOUX DTR8510

• calculate the ratios
• NiMH battery life of up to 10 hours
• Automatic calibration and balancing
• Low-voltage test
• Digital display ½ display of ratios, winding direction - % deviation
• Degauss function

 

ENERGY POWER ANALYZER CHAUVIN-ARNOUX CA8230

• Voltage range: 6VRMS to 600VRMS AC+DC
• AC current range: 5mA to 6,500A
• DC current range: 1A to 1,700A
• Values: Min., Max., Avg., Peak (+/-), CF
• Power: W, VA, var, DF, THD, cos f, tan f
• Energy: Wh, VAh, varh
• Harmonics: up to the 50th order
• IEC1010/EN61010: Cat.III-600V

 

DIGITAL INSULATION MEGOHMMETER 100V CHAUVIN ARNOUX CA6531

• insulation: up to 400MO at 50V and 100V
• AC voltage measurement: 0 to 400V
• voltage indication before measurement of insulation: 0 to 600V AC/DC (blocking if U>25V)
• resistance: 0 to 40kO
• capacity: 0 to 4000nF
• current: 0 to 400mA AC/DC


EARTH RESISTANCE TESTER CHAUVIN ARNOUX CA6421

• earth resistance: 0.5Oat 1,000 O (log scale) )
• 3 fault presence indicators to validate the measurement
• measurement frequency: 128Hz
• connection of rods to colour-coded terminals
• removable captive connection strip between S and H for 2-wire resistance measurements


EARTH RESISTANCE DIGITAL TESTER CHAUVIN ARNOUX CA6423

• earth resistance: 0.00 to 2,000O (3 cal.)
• 3 fault presence indicators to validate the measurement
• measurement frequency: 128Hz
• connection of rods to colour-coded terminals
• a removable captive connection strip between H and S for measurement of 2-wire resistance
• large 2,000-count digital display with 18mm digits: excellent readability


MEGOHMMETER 10KV CHAUVIN ARNOUX CA6550

• Wide measurement range from 10 kohm to 25 Tohm
• Fixed or programmable test voltage from 40V to 10 kV
• 5mA max charging current
• Large backlit LCD screen with digital display, bargraph and R(t)+u(t), i(t) and i(u) graphs
• Automatic ratio calculation: DAR / PI / DD / DR (ppm/V)