• HPA 35, AC testing up to 35 kVrms• HPA 50 / 58 AC testing up to 50 / 58 kVrms• HPA 78, AC testing up to 78 kVrms
• Powerful test- and burning system• Continuous testing with AC voltages up to 100 kVrms at 5 kVA• Own noise-level below 1 pC• Built-in overcurrent protection• DC testing up to 130 kV with optional rectifier
• Compact and lightweight • Continuous testing with AC voltages up to 75 kVrms at 1 kVA • Expandable with a second transformer for testing up to 150 kVrms • Built-in overload protection • DC testing up to 80 kV with optional rectifier
• DC output voltage of 0 - 25 kV• Portable HV Tester• DC and insulation testing of cables, joints, electrical fixtures, etc.• High flexibility with built-in battery
• available in three versions: 50kV 80kV 110kV DC• Highest safety by monitoring functions and easy operation• Quick and easy mounting with compact and simple setup• Meeting individual needs by modular design
• generate a DC voltage of up to 40 kV• Ideal for field application because of its low weight and compact design• High safety due to internal discharge facility• High flexibility with the external battery• Over-current tripping
• fully insulated test set for DC testing up to 70 kV• Testing of cables, switchgear, current-transformers, MV plant/ component testing, • Highest safety thanks to fully insulated design• Compact and lightweight• Separate control and HV-unit• Voltage continuously adjustable• Expandable with a VLF CR attachment for VLF testing on MV cables
• HPG 50-D, AC testing up to 35 kVRMS/ DC testing up to 100 kV• HPG 70 / 80-D, AC testing up to 50 / 58 kVRMS / DC testing up to 140 / 150 kV• Suitable for AC testing and DC testing• Compact, cast-resin high-voltage transformers• Separate control and HV-units• Voltage continuously adjustable• Powerful system: 1,2 kVA continuous operation, up to 3 kVA 60 min. short-time operation
• HPG 50-H, AC testing up to 35 kVRMS / DC-testing up to 50 kV• HPG 70 / 80-H, AC testing up to 50 / 58 kVRMS / DC-testing up to 70 / 80 kV• HPG 110-H, AC testing up to 78 kVRMS / DC-testing up to 110 kV• Suitable for AC-testing and DC-testing• Compact, cast-resin high-voltage transformers• Separate control and HV-units• Voltage continuously adjustable• Powerful system: 1,2 kVA continuous operation, up to 3 kVA 60 min. short-time operation
• DC voltages of up to 400 kV and 650 kV• Great mobility• Simple, safe operation• Thermal overload shutdown• Discharge switch
• simplified version of the standard VLF test• Easy to operate• Configurable test sequences• Compact, rugged and lightweight design• AC, DC and sheath testing in one single system• Reporting via USB or Winkis
• VLF Test System 20 kV • high test capacity of 3 µF permits the simultaneous testing of all three phases• method is officially recommended by the two VDE Standards 0276-620 and 0276-621• VLF is the most economic method for testing PE and XLPE cables
• VLF CR-28 up to cable series 15 kV• VLF CR-40 up to cable series 23 kV• VLF CR-60 up to cable series 35 kV • VLF, DC and sheath fault testing in one device• Portable thanks to two-part construction• High test capacitance• Integrated discharge system• Reporting
• Very high test power without frequency reduction• Covers cables up to 20 km @ maximum Voltage• No polarisation effects as with DC• Protocoling• Breakdown detection• Leakage current measurement• Powerful 0.1 Hz VLF test system with energy recovery
• Powerful 0.1 Hz VLF test system • High test power without frequency reduction• No polarisation effects as by DC testing• Protocoling• Breakdown recognition• Leakage current measurement
• High test capacity of 5 µF• Suitable for outdoor use (IP 54)• Single-button operation easyGO• Integrated safety system• Reporting• Continuous duty cycle
• VLF sine wave 45 kV with integrated tanDelta• compact, robust, and portable • high-performance test and diagnostic system for medium voltage cables• Performs cable withstand testing, cable diagnosis, and sheath fault pinpointing• Automatically adjusts the test frequency to the cable length• Eliminates hazards to the user and guarantees limited damage to the cable• Easy field operation with no need for external computer
• High test capacity of 5 µF• Single-button operation "easyGo"• Continuous duty cycle• Integrated safety system• Suitable for diagnosing 45 kV rated cables
• Adjustable current limiter• Easy and powerful testing of cable jackets• Pulsed output voltage for sheath fault pinpointing• Burning of cable faults