Seba KMT VFL CR-28..60 VLF Test Systems for Medium Voltage Cable Testing

Code: Seba-KMT VLF-CR-28..60


 

Datasheet PDF, 0.61 Mb
         

Description

VLF CR-28...60kV

The portable, high-performance and energy-efficient VLF test systems are used for testing cables with 0.1 Hz cosine-rectangular voltage according to IEC/IEEE/CENELEC standards. In accordance with guidelines, the dielectric strength of cables and joints must be checked after installation or repair. 

The VLF test systems from SebaKMT have high test-capacities and are still compact, because of the patented voltage wave-shape and the power-recycling during polarity reversal. Aside from cable and sheath testing, the test systems can also be used for the precise pinpointing of sheath faults (in combination with a step-voltage probe). 

In total three portable systems are available, each with different voltage levels (28, 40 and 60 kVrms):

- VLF CR-28 up to cable series 15 kV
- VLF CR-40 up to cable series 23 kV
- VLF CR-60 up to cable series 35 kV 

Key benefits:

  • VLF, DC and sheath fault testing in one device
  • Portable thanks to two-part construction
  • High test capacitance
  • Integrated discharge system
  • Reporting

 

 

Standard accessories

Delivery includes:

Basic equipment

Cable set HV/LV

Accessory bag

 

Recommended options

Options:

Transport container for offshore use

ESG NT step-voltage probe

 

More products SEBAKMT

SEBA BPS 5000-D BURN AND PROOF TEST SYSTEM ON MEDIUM VOLTAGE CABLES BPS-5000D BPS500D BPS 5000D-VLF

• Easy-go single button operation
• Protocolling of the test results
• Data transfer via Bluetooth
• DC burn current up to 6 A
• AC burn current up to 110 A
• Sheath fault pinpoiting mode

 

SEBA KMT TAN DELTA CABLE CONDITION DIAGNOSIS SYSTEM

• Very accurate measurement
• Optional leakage current correction
• High wireless range
• Measurement at high voltage potential
• Light and portable

 

SEBA KMT PD LOC PARTIAL DISCHARGE PINPOINTING SYSTEM FOR RPECISE LOCATION OF PD FAULTS IN MEDIUM VOLTAGE CABLES

• Precise PD pinpointing in mixed cable networks
• Location of faults in joints of single core cables
• Easy handling in the ?eld

 

SEBA KMT HPG 50..80-D DC & AC HIGH VOLTAGE CABLE TESTER

• HPG 50-D, AC testing up to 35 kVRMS/ DC testing up to 100 kV
• HPG 70 / 80-D, AC testing up to 50 / 58 kVRMS / DC testing up to 140 / 150 kV
• Suitable for AC testing and DC testing
• Compact, cast-resin high-voltage transformers
• Separate control and HV-units
• Voltage continuously adjustable
• Powerful system: 1,2 kVA continuous operation, up to 3 kVA 60 min. short-time operation

 

SEBA SWG 505 SURGE WAVE GENERATOR FOR FAULT LOCATION IN CABLES SWG505

• Voltage Ranges : 0.. 3kV / 4kV / 5kV
• Energy : 180J / 320J / 500J
• MAx Current Imax : 129mA / 182mA / 213mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method
• ARM - Arc Reflection Method

 

SEBA DIGIFLEX COM REFLECTOMETER FAULT LOCATING ON METALLIC TELECOMM LINES, COAXIAL AND POWER CABLES

• Measuring range from 5 m up to 30 km
• Line comparison with 2 measuring inputs
• High resolution in the near and far range
• Weatherproof case
• Solid housing for rugged fi eld use

 

SEBA TELEFLEX T3060 SINGLE-PHASE POWER CABLE REFLECTOMETER T 3060

• Range 8 km, 64 km (for ICE and Decay only)
• Fully equipped reflectometer with cursor, gain, and range adjustment
• High-contrast 5.7’’ TFT color display (640 x 480 pixel), with LED backlight
• Single-phase ARM input with ICE, Decay and Trigger
• AC or battery operated (up to 3 hours battery life)

 

SEBA KMT MFM 10 CABLE STEATH FAULT LOCATION SYSTEM

• Testing, prelocation and pinpointing of sheath faults
• Voltage up to ±10 kV DC
• High current of up to 750 mA
• Only one HV connection cable
• Automatic measurement and protocolling

 

SEBA SURGEFLEX SFX-32 SPG-32 CABLE FAULT LOCATING SYSTEM

• »» DC-testing up to 32 kV
• »» Prelocating
• - Reflection measurement
• - ARM measurement
• (Arc Reflection Method) up to 32 kV
• - Decay up to 32 kV
• - ICE Impulse Current Method
• 0…4 / 8 / 16 / 32 kV
• »» Burning (fault conditioning) up to 32 kV
• »» Cable tracing (optional)
• »» Pinpointing
• - Distance and acoustic measurement
• 0 … 8 / 16 / 32 kV at 1750 J

 

SEBA EASYFLEX COM REFLECTOMETER LOCATE FAULTS ON CU TELECOMMUNICATION, SIGNAL AND POWER CABLES

• Test range 50 m ... 15000 m
• High local resolution of 5 cm in 50 m test range
• Simple operation due to menu prompting and help functions
• Easy evaluation of the traces by simultaneous display of zoom and total view (split-screen)
• Large display with backlight
• Individual measurement, continuous measurement and averaging
• Measuring connections suitable for live voltage up to 250 V