Seba KMT vLoc-9800 Line Location and Tracer for Underground Pipes and Cables

Code: Seba-KMT vLoc-9800


 

Datasheet PDF, 0.48 Mb

Description

vLoc-9800

The vLoc-9800 is a new entry in the vLoc product line, building upon the Metrotech tradition of performance and convenience. In many sectors, underground cables are located using a method developed by Metrotech 30 years ago: the Distance Sensitive Left/Right GuidanceTM. Most manufacturers offer left/right guidance via a peak/zero antenna set. 

The vLoc-9800 has two horizontal guidance antennae, positioned at a certain distance from each other. This enables a precise distinguishing of left from right. The guidance antennae and the extremely high sensitivity ensure a clear and fast response for easier and precise location. 

Key benefits:

  • Clearly laid out user interface
  • Automatic or manual amplification options
  • Depth and amperage at the press of a button
  • Distance Sensitive Left/Right GuidanceTM
  • Sheath fault location (optional)

 

 

Standard accessories

 

 

Recommended options

 

 

More products SEBAKMT

SEBAKMT HL7000 ELECTROACOUSTIC WATER LEAK DETECTION

• Completely wireless thanks to Bluetooth®
• Intuitive operation via touch color display
• Powerful lithium-ion batteries
• Integrated GPS receiver
• Ambient/noise cancellation
• Frequency analysis

 

SEBA SURGEFLEX SFX-40 SPG-40 CABLE FAULT LOCATING SYSTEM

• DC Testing up to 40 kV ARM, ICE and Decay Method integrated
• Operation by VGA Display and single button rotary encoder
• High surge energy fort he acoustic pinpointing 1000 or 2000 J
• Surge voltage levels for MV cablel 0 ... 12,5/25 kV or 0 ... 16/32 kV
• Surge voltage levels for lower voltage 0 ... 3/6 kV or 0 ... 4/8 kV
• Integrated safety system

 

SEBA KMT OWTS M28 PARTIAL DISCHARGE TEST AND FAULT LOCATION SYSTEM IN CABLE INSULATION

• PD Measurement by means of DAC similar to nominal net frequency
• Online processing for complex PD-Diagnosis
• Portable test system, compact design and low weight
• Integrated tan d - measurement

 

SEBA KMT VFL CR-80 46KV HIGH VOLTAGE CABLE TEST SYSTEMS

• Powerful 0.1 Hz VLF test system
• High test power without frequency reduction
• No polarisation effects as by DC testing
• Protocoling
• Breakdown recognition
• Leakage current measurement

 

SEBA SWG 8-1000 SURGE UNIT HIGH VOLTAGE GENERATOR FOR CABLE FAULT LOCATING SWG8-1000

• Voltage Ranges : 0..2kV / 0..4kV / 0..8kV
• Energy : 1000 Joules
• MAx Current Imax : 1400mA / 700mA / 500mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method
• ARM - Arc Reflection Method

 

SEBA KMT OWTS M60 DIELECTRIC DIAGNOSIS AND PARTIAL DISCHARGE MEASURING SYSTEM

• PD diagnosis under oscillating wave test voltage
• PD evaluation possibility and pattern recognition at the nominal voltage level
• Automatic Calibration and Joint location facility
• PD level measurement according to IEC 270 at a bandwidth of 150 ... 650 kHz
• Semi- and fully automatic PD analysing software for defect location with mapping feature
• Calculation of the cable capacitance and the tan delta value
• Simple to use and easy to handle menu-driven unit for operation of the test sequence
• Compact design; low weight

 

SEBA SMART THUMP 16 CABLE FAULT LOCATION SYSTEM ON LOW AND MEDIUM VOLTAGE CABLES

• 1500J at 8 / 16 kV, 16 kV DC-HV proof test 23/46mA Burning
• Integrated ARM and ICE Prelocation
• Easy Go - automatic sequence to proof test, pre-locate & pinpoint
• Automatic interpretation of test results
• Sunlight readable, transflective 5.7" TFT colour display
• Safe OP Check protects user from incorrect or faulty lead connections
• USB interface for trace export via USB flash drive

 

SEBA DIGIPHONE+ SURGE WAVE RECEIVER FOR ACOUSTIC AND ELECTROMAGNETIC FAULT PINPOINTING IN CABLES

• Perfect acoustic quality and noise immunity
• Automatic mute function to protect your ears
• Bright, transflective sun readable display
• Easiest handling with automatic adjustment
• Earphone volume limitation to 84 dB(A)

 

SEBA SURGEFLEX SFX-32 SPG-32 CABLE FAULT LOCATING SYSTEM

• »» DC-testing up to 32 kV
• »» Prelocating
• - Reflection measurement
• - ARM measurement
• (Arc Reflection Method) up to 32 kV
• - Decay up to 32 kV
• - ICE Impulse Current Method
• 0…4 / 8 / 16 / 32 kV
• »» Burning (fault conditioning) up to 32 kV
• »» Cable tracing (optional)
• »» Pinpointing
• - Distance and acoustic measurement
• 0 … 8 / 16 / 32 kV at 1750 J

 

SEBA TELEFLEX-VX ADAPTER FOR SAFE OPERATION OF REFLECTOMETERS ON OVERHEAD LINES

• Very easy to operate
• Very good resolution, for both near and distant ranges
• Dangerous induction voltages reliably discharged
• Connection to a measurement system
• Test pulses up to 1,500 V for long distances
• For distances over 2,000 km