PVS 100

The exact knowledge of the phase assignment in the area of power distribution is an essential requirement for the safe and reliable power network operation. This covers all voltage levels from a low voltage distribution to high voltage transmission systems. A phase identification or verification is required for the determination of load distribution, the control of the phase assignment of old or new installation and prior to switching to avoid damages and outages. The phase identification with the PVS 100 enhances the safety of power distribution systems and prevents accidents.

Key benefits:

  • Clear determination of the phase assignment in respect to a reference phase
  • Determination of the phase by GPS synchronisation and GSM connection
  • Offline measurement without data connection by post synchronisation possible
  • Easy entry and correction of transformer vector groups
  • Reliable function in all voltage levels
  • Easiest operation

 

 

  • Identifies the phase at all voltage levels in real time
  • Functions with and without a permanent data connection
  • Easy to operate
  • Eliminates safety risks
  • Saves time and money

 

All the advantages at a glance

Direct phase indication with a GSM/GPS connection or with an available low voltage connection

Extremely easy input of phase shifts/vector groups by using the zero key

Can operate independently of GSM or GPS reception with synchronisation

of the stored readings

Internal memory for 10 days of continuous operation

Li-Ion battery for 10 hours of operation

Data transfer via USB

Operation via LCD touch screen

Intuitive operating software

High voltage sensor with bidirectional wireless transmission to PVS 100

and direct visual signalling

 

 

 

 

Standard accessories

Phase verification system,

full set

»» 2 x PVS 100 incl. GPS outdoor unit

»» High voltage sensor with probe tips

»» Insulating rod 110 kV

»» 2 x cable set

»» Tripod for GPS module with holder

»» PVS probe for capacitive taps

»» Charger for HVS 120-36 and PVS probe

»» 2 GSM aerials with holder

»» 2 cases/trolleys for PVS 100

Phase verification system,

additional device

»» 1 x PVS 100 incl. GPS outdoor unit

»» High voltage sensor with probe tips

»» I nsulating rod 110 kV

»» Cable set

»» Tripod for GPS module with holder

»» PVS probe for capacitive taps

»» Charger for HVS 120-36 and PVS probe

»» GSM aerial with holder

»» 1 case/trolley for PVS 100

 

 

Recommended options

 

 

More products SEBAKMT

SEBA SURGEFLEX SFX 8-1000 CABLE FAULT LOCATING SYSTEM

• Small, light and portable
• Very low voltage levels
• Complete fault location with DC Testing up to 8 kV
• Prelocation with ARM and ICE
• Burning with up to 1.4 A

 

SEBA KMT VLOC-5000 LINE LOCATION AND TRACER FOR UNDERGROUND PIPES AND CABLES

• Precise direction guidance with right/left arrows and guidance compass
• SiS ("Signal Select") and SD ("Signal Direction") for reliable line identification
• "Distortion Alert" for signal evaluation
• Internal GPS receiver and data storage
• Permanent depth or signal current intensity measurement

 

SEBA KMT T26/1 T26/1A T26/1B T26/1C HIGH VOLTAGE CABLE TESTING

• DC voltages of up to 400 kV and 650 kV
• Great mobility
• Simple, safe operation
• Thermal overload shutdown
• Discharge switch

 

SEBA SWG 1750 SURGE WAVE GENERATOR FOR FAULT LOCATION IN CABLES SWG1750 SWG1750C SWG1750CI SWG1750C-4 SWG1750CD

• Voltage Ranges : 0.. 8kV / 0..16kV / 0..32kV
• SWG 1750C with 8 - 16 - 32 kV / 1750 J
• SWG 1750 CI with 8 - 16 - 32 kV / 1750 J, incl. leakage current measurement
• SWG 1750 C-4 with 2 - 4 kV / 1150 J and 8 - 16 - 32 kV / 1750 J
• SWG 1750 CD with 8 - 16 - 32 kV / 3500 J

 

SEBA KMT HPG 70-K 70KV DC HIGH VOLTAGE HIPOT TESTER

• fully insulated test set for DC testing up to 70 kV
• Testing of cables, switchgear, current-transformers, MV plant/ component testing,
• Highest safety thanks to fully insulated design
• Compact and lightweight
• Separate control and HV-unit
• Voltage continuously adjustable
• Expandable with a VLF CR attachment for VLF testing on MV cables

 

SEBA SWG 505 SURGE WAVE GENERATOR FOR FAULT LOCATION IN CABLES SWG505

• Voltage Ranges : 0.. 3kV / 4kV / 5kV
• Energy : 180J / 320J / 500J
• MAx Current Imax : 129mA / 182mA / 213mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method
• ARM - Arc Reflection Method

 

SEBA SFX 5-1000 SPG 5-1000 CABLE FAULT LOCATION SYSTEM ON LOW AND MEDIUM VOLTAGE CABLES

• ICEplus for the easy and reliable fault prelocation without interference from branches
• High surge energy for pinpointing
• Compact and lightweight construction
• Testing up to 5 kV
• Automatic detection of the breakdown voltage
• Pinpointing with the integrated surge generator 0 … 2 / 4 kV 1000 J
• Pulsed DC for sheath fault pinpointing

 

SEBA KMT VFL CR-60-HP LONG CABLES TEST SYSTEMS

• Very high test power without frequency reduction
• Covers cables up to 20 km @ maximum Voltage
• No polarisation effects as with DC
• Protocoling
• Breakdown detection
• Leakage current measurement
• Powerful 0.1 Hz VLF test system with energy recovery

 

SEBA SWG 500 SURGE WAVE GENERATOR FOR FAULT LOCATION IN CABLES SWG500

• Voltage Ranges : 0..2.5kV / 5kV / 10kV ; 0..4kV / 8kV / 16kV
• Energy : 195J ; 500Joules
• MAx Current Imax : 185mA ; 300mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method
• ARM - Arc Reflection Method

 

SEBA SWG 8-1000 SURGE UNIT HIGH VOLTAGE GENERATOR FOR CABLE FAULT LOCATING SWG8-1000

• Voltage Ranges : 0..2kV / 0..4kV / 0..8kV
• Energy : 1000 Joules
• MAx Current Imax : 1400mA / 700mA / 500mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method