Seba BPS 5000-d Burn and Proof Test System on Medium Voltage Cables BPS-5000d BPS500d BPS 5000d-VLF

Code: Seba-KMT BPS5000-d BPS-5000d BPS500d BPS5000d-VLF


 

Datasheet PDF, 0.31 Mb
     

Description

BPS 5000-d

The BPS system is typically installed into cable test systems, but is also available as stand alone version for burning and testing.

The digital control allows an easy operation as burn unit for the conversion of difficult to locate cable faults and permits the operation of aconnected HV DC test system and a VLF cosine rectangular test system. 

Key benefits:

  • Easy-go single button operation
  • Protocolling of the test results
  • Data transfer via Bluetooth
  • DC burn current up to 6 A
  • AC burn current up to 110 A
  • Sheath fault pinpoiting mode

 

 

 

 

 

Standard accessories

 

 

Recommended options

Options

»» Device for system integration

»» Stand-alone system (mobile)

»» VLF test system

»» DC voltage test

»» ESG NT for sheath fault location

 

 

 

 

More products SEBAKMT

SEBA KMT HPG 50..110-H DC & AC HIGH VOLTAGE CABLE TESTING SETS

• HPG 50-H, AC testing up to 35 kVRMS / DC-testing up to 50 kV
• HPG 70 / 80-H, AC testing up to 50 / 58 kVRMS / DC-testing up to 70 / 80 kV
• HPG 110-H, AC testing up to 78 kVRMS / DC-testing up to 110 kV
• Suitable for AC-testing and DC-testing
• Compact, cast-resin high-voltage transformers
• Separate control and HV-units
• Voltage continuously adjustable
• Powerful system: 1,2 kVA continuous operation, up to 3 kVA 60 min. short-time operation

 

SEBA SWG 8-1000 SURGE UNIT HIGH VOLTAGE GENERATOR FOR CABLE FAULT LOCATING SWG8-1000

• Voltage Ranges : 0..2kV / 0..4kV / 0..8kV
• Energy : 1000 Joules
• MAx Current Imax : 1400mA / 700mA / 500mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method
• ARM - Arc Reflection Method

 

SEBA KMT HVB-10 10KV CABLE FAULT LOCATION, STEATH TESTING AND PINPOINTING MEGGER HVB10

• Output voltage 0 … 10 kV DC, bi-polar
• Automatic test sequence
• Bi-polar prelocation for the elimination of external influences
• Detection and indication of wrong connections
• Touchscreen and rotary encoder
• Only one HV connection cable
• Completely independent of the parameters of auxiliary lines

 

SEBA SURGEFLEX SFX 8-1000 CABLE FAULT LOCATING SYSTEM

• Small, light and portable
• Very low voltage levels
• Complete fault location with DC Testing up to 8 kV
• Prelocation with ARM and ICE
• Burning with up to 1.4 A

 

SEBA KMT VFL SINUS 34KV 0.1HZ SINE WAVE CABLE TEST SYSTEMS

• High test capacity of 5 µF
• Suitable for outdoor use (IP 54)
• Single-button operation easyGO
• Integrated safety system
• Reporting
• Continuous duty cycle

 

SEBA KMT T99/1 40KV DC HIGH VOLTAGE TEST UNIT

• generate a DC voltage of up to 40 kV
• Ideal for field application because of its low weight and compact design
• High safety due to internal discharge facility
• High flexibility with the external battery
• Over-current tripping

 

SEBA TELEFLEX-VX ADAPTER FOR SAFE OPERATION OF REFLECTOMETERS ON OVERHEAD LINES

• Very easy to operate
• Very good resolution, for both near and distant ranges
• Dangerous induction voltages reliably discharged
• Connection to a measurement system
• Test pulses up to 1,500 V for long distances
• For distances over 2,000 km

 

SEBA SFX 5-1000 SPG 5-1000 CABLE FAULT LOCATION SYSTEM ON LOW AND MEDIUM VOLTAGE CABLES

• ICEplus for the easy and reliable fault prelocation without interference from branches
• High surge energy for pinpointing
• Compact and lightweight construction
• Testing up to 5 kV
• Automatic detection of the breakdown voltage
• Pinpointing with the integrated surge generator 0 … 2 / 4 kV 1000 J
• Pulsed DC for sheath fault pinpointing

 

SEBA KMT OWTS M28 PARTIAL DISCHARGE TEST AND FAULT LOCATION SYSTEM IN CABLE INSULATION

• PD Measurement by means of DAC similar to nominal net frequency
• Online processing for complex PD-Diagnosis
• Portable test system, compact design and low weight
• Integrated tan d - measurement

 

SEBA SWG 505 SURGE WAVE GENERATOR FOR FAULT LOCATION IN CABLES SWG505

• Voltage Ranges : 0.. 3kV / 4kV / 5kV
• Energy : 180J / 320J / 500J
• MAx Current Imax : 129mA / 182mA / 213mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method
• ARM - Arc Reflection Method