Seba KMT HV Tester 25kV High Voltage DC Tester

Code: Seba-KMT HV-Tester-25kV


 

Datasheet PDF, 0.39 Mb

Description

HV Tester 25

The HV Tester 25 kV is a high-voltage generator with an infinitely variable negative DC output voltage of 0 - 25 kV. The condition of the test object with regard to electrical strength and insulation quality can be determined on the basis of the unit's readings for output voltage and current. 

Key benefits:

  • Portable HV Tester
  • DC and insulation testing of cables, joints, electrical fixtures, etc.
  • High flexibility with built-in battery

 

 

Description

The HV Tester 25 kV is a highvoltage generator with a variable negative DC output voltage of 0 … 25 kV.

 

The HV Tester 25 kV is used for:

Testing of newly installed cables and splices before they are taken into service

Testing of disconnected cables

Testing of electrical installations

Preventive checks after repairs and work on cables and other installations

 

Technical features

Easy operation

Built-in rechargeable battery for mains independent

operation

Low weight and compact design

Integrated discharge

Built-in timer

Stabilized adjustable output voltage

Voltage measurement direct at high-voltage output

HV-on with 0 kV interlock

Output short-circuit and open-circuit proof

Grounding safety circuit

 

 

Standard accessories

Scope of Delivery

Tester, incl. rechargeable battery and leather case

Mains lead

Battery lead for external DC battery, approx. 3 m

Ground lead, approx. 3 m, for connection to station ground

Ground lead, approx. 3 m, for connection to protective ground

High voltage lead, approx. 3 m, with terminal

Operating manual

 

 

Recommended options

 

 

More products SEBAKMT

SEBA KMT GEOLUX GL 660-1 EARTH FAULT LOCATOR FOR FAULT LOCATION IN ISOLATED, EARTH FREE SYSTEMS

• Earth fault locator for fault location in isolated, earth free systems
• Mains filter for direct coupling to live cables up to 660 V
• Pulsed output current for easier detection of the test signal
• Filter for the suppression large interference signals
• Location of earth faults up to 150 kOhm
• No switch off during the fault location required
• No influence to the signal lines connected to

 

SEBA KMT BT 500 IS-1 CABLE FAULT CONVERTER

• Overload protection
• Automatic discharge
• Burning of high resistive faults
• Low- potential free voltage avoids damage to other conductors
• Adjustable current limiter

 

SEBA TELEFLEX SX CABLE REFLECTOMETER FOR FAULT LOCATION MEGGER

• ARMslide technology with 15 traces in one ARM shot
• ProRange for optimised display of distant details
• Support of all existing prelocation technologies
• Automatic adjustment and display of cable end and fault
• Compatible with all fault location systems

 

SEBA FAULT SNIFFER FOR DETECTION OF BURNING GASES FROM FAULT CABLES UNDERGROUND

• Customers can stay connected
• Fault location with no supply interrupt
• Reliable avoidance of incorrect excavations
• Fast and easy location of faults
• Can be used on straight or branched networks
• Handy size, easy to transport
• No pre-location required
• Accuracy in the decimetre range
• Sensitive to several specifi c gases and therefore suitable for any insulation material

 

SEBA KMT CI LCI CABLE IDENTIFIER TEST SET

• Inexpensive cable selection system
• Easy to operate
• Safe handling
• Very small

 

SEBA KMT SEBALOG CORR MULTI-CORRELATOR LOGGER FOR WATER LEAK DETECTION AND LOCATION

• Correlation with up to 8 sensors at the same time
• GPS navigation directly to the leak
• Radio communication to the sensors
• No staff needed for night measurement
• Sound velocity assistant (V-assistant)
• Unique pinpointing mode

 

SEBA KMT HV TESTER 25KV HIGH VOLTAGE DC TESTER

• DC output voltage of 0 - 25 kV
• Portable HV Tester
• DC and insulation testing of cables, joints, electrical fixtures, etc.
• High flexibility with built-in battery

 

SEBA KMT CDS CABLE DIAGNOSTIC SYSTEM FOR THREE PHASE IRC AND RVM DIAGNOSTICS

• Absolutely non-destructive condition evaluation of PE / XLPE / paper-oil insulated cable systems
• Simple operation and automatic measurement procedures
• Three-phase parallel measurement for current and voltage - duration of a complete measurement 1 hour
• Extended dynamic range for IRC measurement for long cable segments
• Measurement of charging current during formation

 

SEBA SMART THUMP 16 CABLE FAULT LOCATION SYSTEM ON LOW AND MEDIUM VOLTAGE CABLES

• 1500J at 8 / 16 kV, 16 kV DC-HV proof test 23/46mA Burning
• Integrated ARM and ICE Prelocation
• Easy Go - automatic sequence to proof test, pre-locate & pinpoint
• Automatic interpretation of test results
• Sunlight readable, transflective 5.7" TFT colour display
• Safe OP Check protects user from incorrect or faulty lead connections
• USB interface for trace export via USB flash drive

 

SEBA KMT PD SURVEYOR AIR PARTIAL DISCHARGE DETECTOR FOR MEDIUM VOLTAGE CABLES, SWITCHGEAR, PLANTS

• Three PD sensor technologies in one device
•  Early detection of PD activity
•  Universal application - can be applied to
• MV cables, MV switchgear & other types of MV plants
•  Directs maintenance resources straight to the problem areas
•  Easy to use