Seba KMT Ferrolux FLE 10 Audio Frequency Receiver for Cable Location, Selection, Sheath Faults

Code: Seba-KMT Ferrolux-FLE10


 

Datasheet PDF, 3.66 Mb
     

Description

Ferrolux FL 10

The Ferrolux location system is the solution for your day-to-day tasks. You can use the system to quickly and easily find cable faults. You can locate lines just as quickly, measure how deep they are and save data in the memory.

The route sensor for location tasks weighs less than 1 kg, which means you can use it for lengthy periods without getting tired. Special features such as the SuperMax Signal, DirectSignal and SignalSelect make your job easier and the results more accurate.

Benefits:

  • Precise direction guidance with right/left arrows
  • "SignalSelect" for clear route location
  • Depth and signal current intensity measurement at the push of a button
  • Route sensor weighs less than 1 kg for non-tiring use
  • "DirectSignal" for effective line location

The Ferrolux system is available with the following generators:

 

 

 

Standard accessories

 

 

Recommended options

 

 

More products SEBAKMT

SEBA TELEFLEX-VX ADAPTER FOR SAFE OPERATION OF REFLECTOMETERS ON OVERHEAD LINES

• Very easy to operate
• Very good resolution, for both near and distant ranges
• Dangerous induction voltages reliably discharged
• Connection to a measurement system
• Test pulses up to 1,500 V for long distances
• For distances over 2,000 km

 

SEBA SWG 500 SURGE WAVE GENERATOR FOR FAULT LOCATION IN CABLES SWG500

• Voltage Ranges : 0..2.5kV / 5kV / 10kV ; 0..4kV / 8kV / 16kV
• Energy : 195J ; 500Joules
• MAx Current Imax : 185mA ; 300mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method
• ARM - Arc Reflection Method

 

SEBA SWG 8-1000 SURGE UNIT HIGH VOLTAGE GENERATOR FOR CABLE FAULT LOCATING SWG8-1000

• Voltage Ranges : 0..2kV / 0..4kV / 0..8kV
• Energy : 1000 Joules
• MAx Current Imax : 1400mA / 700mA / 500mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method
• ARM - Arc Reflection Method

 

SEBA TELEFLEX LV MONITOR CABLE FAULT LOCATION SYSTEM WITH MONITORING MEGGER

• Fault location on live low voltage cables
• 3 phase cable monitor for a permanent check of current and voltage
• GSM remote controlled system

 

SEBA KMT PVS-100 PHASE IDENTIFICATION TESTER FOR CABLE SELECTION

• Identifies the phase at all voltage levels in real time
• Functions with and without a permanent data connection
• Easy to operate
• Eliminates safety risks
• Saves time and money

 

SEBA KMT VFL SINUS 34KV 0.1HZ SINE WAVE CABLE TEST SYSTEMS

• High test capacity of 5 µF
• Suitable for outdoor use (IP 54)
• Single-button operation easyGO
• Integrated safety system
• Reporting
• Continuous duty cycle

 

SEBA KMT HPG 70-K 70KV DC HIGH VOLTAGE HIPOT TESTER

• fully insulated test set for DC testing up to 70 kV
• Testing of cables, switchgear, current-transformers, MV plant/ component testing,
• Highest safety thanks to fully insulated design
• Compact and lightweight
• Separate control and HV-unit
• Voltage continuously adjustable
• Expandable with a VLF CR attachment for VLF testing on MV cables

 

SEBA KMT VCAM LSR SEWER PIPELINE VIDEO INSPECTION CAMERA

• Flexibility, allowing multiple uses
• 3 camera head options
• Recording of the video via the VIDEO OUT
• Integrated distance counter and 640 Hz sonde
• Integrated rechargeables
• Expandable, with flex rod incorporating 9 or 11 mm diameter camera head

 

SEBA KMT VLOC-5000 LINE LOCATION AND TRACER FOR UNDERGROUND PIPES AND CABLES

• Precise direction guidance with right/left arrows and guidance compass
• SiS ("Signal Select") and SD ("Signal Direction") for reliable line identification
• "Distortion Alert" for signal evaluation
• Internal GPS receiver and data storage
• Permanent depth or signal current intensity measurement

 

SEBA KMT T22/1 AC HIGH VOLTAGE TESTING SYSTEM

• Compact and lightweight
• Continuous testing with AC voltages up to 75 kVrms at 1 kVA
• Expandable with a second transformer for testing up to 150 kVrms
• Built-in overload protection
• DC testing up to 80 kV with optional rectifier