Seba KMT MMG 10 Cable Sheath Tester

Code: Seba-KMT MMG10 MMG-10


 

Datasheet PDF, 0.3 Mb
 

Description

MMG 10

The sheath test system MMG 10 is used for the voltage testing of plastic insulated cable jackets. The test evaluated the leakage current in respect to the cable lengths. An adjustable current limiter avoids an eventual drying or unintended change of a fault spot. The high output current can also be used for the low resistive burning of a fault. For pinpointing of sheath faults in plastic insulated shielded cables and earth faults in unshielded cables, the MMG 10 provides a pulsed output voltage. The pinpointing is done by the step voltage method with the Earth fault locator ESG 80-2 / ESG NT. 

The MMG 10 can also be used as Burn voltage supply for the Arc Reflection Burning with the ETF 3. 

Key benefits:

  • Adjustable current limiter
  • Easy and powerful testing of cable jackets
  • Pulsed output voltage for sheath fault pinpointing
  • Burning of cable faults

 

 

Standard accessories

 

 

Recommended options

Accessory equipment

_ Earth Fault Locating Device ESG 80-2

_ Earth spikes with measuring

leads EEB

_ Sheath-Fault Prelocating

Device MVG 5

(Prelocation up to 5 kV)

_ Emergency-off switch NAG 1 for stand-alone

operation

For operation with Sheath Fault Prelocating Device MVG 5:

_ Emergency-off switch NAG 2

 

More products SEBAKMT

SEBA KMT PD LOC PARTIAL DISCHARGE PINPOINTING SYSTEM FOR RPECISE LOCATION OF PD FAULTS IN MEDIUM VOLTAGE CABLES

• Precise PD pinpointing in mixed cable networks
• Location of faults in joints of single core cables
• Easy handling in the ?eld

 

SEBA KMT PVS-100 PHASE IDENTIFICATION TESTER FOR CABLE SELECTION

• Identifies the phase at all voltage levels in real time
• Functions with and without a permanent data connection
• Easy to operate
• Eliminates safety risks
• Saves time and money

 

SEBA KMT VFL SINUS 45KV SINE WAVE CABLE TEST SYSTEMS

• VLF sine wave 45 kV with integrated tanDelta
• compact, robust, and portable
• high-performance test and diagnostic system for medium voltage cables
• Performs cable withstand testing, cable diagnosis, and sheath fault pinpointing
• Automatically adjusts the test frequency to the cable length
• Eliminates hazards to the user and guarantees limited damage to the cable
• Easy field operation with no need for external computer

 

SEBA DIGIPHONE+ ESG NT PINPOINTING ACOUSTIC PINPOINTING SET FOR STEATH FAULT LOCATION IN UNDERGROUND CABLES

• Perfect acoustic quality and noise immunity
• Automatic filtration of interfering signals
• Automatic zero calibration, no adjustments necessary
• History mode
• Acoustic and step voltage fault location in one device
• BNR technology for perfect acoustic quality and noise immunity
• Automatic filtration of interfering signals
• Automatic setting of all parameters, no adjustments necessary

 

SEBA KMT HVB-10 10KV CABLE FAULT LOCATION, STEATH TESTING AND PINPOINTING MEGGER HVB10

• Output voltage 0 … 10 kV DC, bi-polar
• Automatic test sequence
• Bi-polar prelocation for the elimination of external influences
• Detection and indication of wrong connections
• Touchscreen and rotary encoder
• Only one HV connection cable
• Completely independent of the parameters of auxiliary lines

 

SEBA KMT T22/1 AC HIGH VOLTAGE TESTING SYSTEM

• Compact and lightweight
• Continuous testing with AC voltages up to 75 kVrms at 1 kVA
• Expandable with a second transformer for testing up to 150 kVrms
• Built-in overload protection
• DC testing up to 80 kV with optional rectifier

 

SEBA KMT HPG 50..110-H DC & AC HIGH VOLTAGE CABLE TESTING SETS

• HPG 50-H, AC testing up to 35 kVRMS / DC-testing up to 50 kV
• HPG 70 / 80-H, AC testing up to 50 / 58 kVRMS / DC-testing up to 70 / 80 kV
• HPG 110-H, AC testing up to 78 kVRMS / DC-testing up to 110 kV
• Suitable for AC-testing and DC-testing
• Compact, cast-resin high-voltage transformers
• Separate control and HV-units
• Voltage continuously adjustable
• Powerful system: 1,2 kVA continuous operation, up to 3 kVA 60 min. short-time operation

 

SEBA TELEFLEX-VX ADAPTER FOR SAFE OPERATION OF REFLECTOMETERS ON OVERHEAD LINES

• Very easy to operate
• Very good resolution, for both near and distant ranges
• Dangerous induction voltages reliably discharged
• Connection to a measurement system
• Test pulses up to 1,500 V for long distances
• For distances over 2,000 km

 

SEBA T18/5 SURGE WAVE VOLTAGE GENERATOR FOR CABLE FAULT LOCATING

• Voltage Ranges : 0..3kV / 0..6kV / 0..12kV
• Energy : 1000 Joules


SEBA KMT T22/13B BURN UNIT FOR TESTING MEDIUM VOLTAGE CABLES T22-13B

• Short circuit proof
• Equipped with new circuity to keep Burn-Down power constant
• Maximal Burn-Down current of 25A
• Burn-Down voltage constinuously variable from 0 to 15 kV
• Indication of output current and voltage
• Integrated start interlock circuit and discharging device
• Pulse mode for earth leakage