Seba KMT T22/1 AC High Voltage Testing System

Code: SebaKMT T-22/1 T22/1


 

Datasheet PDF, 0.32 Mb

Description

T 22/1

The AC Voltage Test Set T 22/1 is a portable test set consisting of two separate units: the control unit and the high-voltage unit. This division enables the operator to use the test set on site without transport aids. The test set can be equipped with a rectifier attachment for DC voltage testing up to 80 kV. 

Key benefits:

  • Compact and lightweight
  • Continuous testing with AC voltages up to 75 kVrms at 1 kVA
  • Expandable with a second transformer for testing up to 150 kVrms
  • Built-in overload protection
  • DC testing up to 80 kV with optional rectifier

 

 

Standard accessories

 

 

Recommended options

 

 

More products SEBAKMT

SEBA KMT VLOC-9800 LINE LOCATION AND TRACER FOR UNDERGROUND PIPES AND CABLES

• Clearly laid out user interface
• Automatic or manual amplification options
• Depth and amperage at the press of a button
• Distance Sensitive Left/Right GuidanceTM
• Sheath fault location (optional)

 

SEBA KMT VM-850 LOCATION UNDERGROUND PIPES AND CABLES

• Easy to use
• High location accuracy
• Optimal inductive transmission of line signals
• Classic design, compact and light

 

SEBA KMT PVS-100 PHASE IDENTIFICATION TESTER FOR CABLE SELECTION

• Identifies the phase at all voltage levels in real time
• Functions with and without a permanent data connection
• Easy to operate
• Eliminates safety risks
• Saves time and money

 

SEBA KMT HVB-10 10KV CABLE FAULT LOCATION, STEATH TESTING AND PINPOINTING MEGGER HVB10

• Output voltage 0 … 10 kV DC, bi-polar
• Automatic test sequence
• Bi-polar prelocation for the elimination of external influences
• Detection and indication of wrong connections
• Touchscreen and rotary encoder
• Only one HV connection cable
• Completely independent of the parameters of auxiliary lines

 

SEBA KMT HPG 50..80-D DC & AC HIGH VOLTAGE CABLE TESTER

• HPG 50-D, AC testing up to 35 kVRMS/ DC testing up to 100 kV
• HPG 70 / 80-D, AC testing up to 50 / 58 kVRMS / DC testing up to 140 / 150 kV
• Suitable for AC testing and DC testing
• Compact, cast-resin high-voltage transformers
• Separate control and HV-units
• Voltage continuously adjustable
• Powerful system: 1,2 kVA continuous operation, up to 3 kVA 60 min. short-time operation

 

SEBA SWG 505 SURGE WAVE GENERATOR FOR FAULT LOCATION IN CABLES SWG505

• Voltage Ranges : 0.. 3kV / 4kV / 5kV
• Energy : 180J / 320J / 500J
• MAx Current Imax : 129mA / 182mA / 213mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method
• ARM - Arc Reflection Method

 

SEBA KMT OWTS M28 PARTIAL DISCHARGE TEST AND FAULT LOCATION SYSTEM IN CABLE INSULATION

• PD Measurement by means of DAC similar to nominal net frequency
• Online processing for complex PD-Diagnosis
• Portable test system, compact design and low weight
• Integrated tan d - measurement

 

SEBA KMT EZ-THUMP CABLE FAULT LOCATION SYSTEM ON LV/MV CABLES

• Easiest, fully automatic operation
• All in one small and portable unit
• ARM Prelocation
• Pinpointing with 500 J
• Available as 4 or 12 kV version
• Bright, brilliant colour display
• Battery operation

 

SEBA BPS 5000-D BURN AND PROOF TEST SYSTEM ON MEDIUM VOLTAGE CABLES BPS-5000D BPS500D BPS 5000D-VLF

• Easy-go single button operation
• Protocolling of the test results
• Data transfer via Bluetooth
• DC burn current up to 6 A
• AC burn current up to 110 A
• Sheath fault pinpoiting mode

 

SEBA FAULT SNIFFER FOR DETECTION OF BURNING GASES FROM FAULT CABLES UNDERGROUND

• Customers can stay connected
• Fault location with no supply interrupt
• Reliable avoidance of incorrect excavations
• Fast and easy location of faults
• Can be used on straight or branched networks
• Handy size, easy to transport
• No pre-location required
• Accuracy in the decimetre range
• Sensitive to several specifi c gases and therefore suitable for any insulation material