Seba KMT PIL 8 Phasenlux Phase identi?cation in earthed and short-circuited medium voltage cables

Code: Seba-KMT PIL-8 Phasenlux


 

Datasheet , 0.33 Mb

Description

Pil 8

The Phase identification System PIL 8 permits a fast and especially safe phase determination at the jointing location during the mounting of medium voltage cables. 

According to DIN VDE 0105 0100 part 2 (EN 50110-1) from Okt. 1997, Pos. 6.2.4.1 Topic 3 (Page 12) it specifies : 

"... If the earthing or shorting has to be removed for the duration of measurements or tests, suitable other safety measures have to be taken." 

Such safety measures require a relatively large effort and are not always practical. The specific advantage of the technology used in the PIL 8 is the fact, that the ground or shorting must not be removed. In opposition, this grounding it is an essential part of the procedure, which means, the cable must be grounded and shorted for the system to work. Resulting the use is absolutely safe. For each phase the according transceiver clamp are installed tot he grounded cable end and then at the selection point each phase is identified and marked. 

Key benefits:

  • Maintenance free transceiver clamps
  • Suitable for any type of switch gear
  • Requires only one person
  • Easiest operation
  • Absolute safe phase identification

 

 

Standard accessories

Scope of delivery

1 pc. Generator/receiver PIL 8

1 set of Cables VL 83-E

3 pairs of Transceiver tongs PIZ 50

1 pc. Transport case PIK 8

 

Special accessories

for each additional end-to-end measurement (3 are

possible) 3 pairs of transceiver tongs PIZ50

 

Recommended options

 

 

More products SEBAKMT

SEBA KMT EASYTEST 20KV VFL CABLE TESTER VERY LOW FREQUENCY

• simplified version of the standard VLF test
• Easy to operate
• Configurable test sequences
• Compact, rugged and lightweight design
• AC, DC and sheath testing in one single system
• Reporting via USB or Winkis

 

SEBA KMT TAN DELTA CABLE CONDITION DIAGNOSIS SYSTEM

• Very accurate measurement
• Optional leakage current correction
• High wireless range
• Measurement at high voltage potential
• Light and portable

 

SEBA DIGIPHONE+ SURGE WAVE RECEIVER FOR ACOUSTIC AND ELECTROMAGNETIC FAULT PINPOINTING IN CABLES

• Perfect acoustic quality and noise immunity
• Automatic mute function to protect your ears
• Bright, transflective sun readable display
• Easiest handling with automatic adjustment
• Earphone volume limitation to 84 dB(A)

 

SEBA KMT EZ-THUMP CABLE FAULT LOCATION SYSTEM ON LV/MV CABLES

• Easiest, fully automatic operation
• All in one small and portable unit
• ARM Prelocation
• Pinpointing with 500 J
• Available as 4 or 12 kV version
• Bright, brilliant colour display
• Battery operation

 

SEBA BPS 5000-D BURN AND PROOF TEST SYSTEM ON MEDIUM VOLTAGE CABLES BPS-5000D BPS500D BPS 5000D-VLF

• Easy-go single button operation
• Protocolling of the test results
• Data transfer via Bluetooth
• DC burn current up to 6 A
• AC burn current up to 110 A
• Sheath fault pinpoiting mode

 

SEBA SWG 8-1000 SURGE UNIT HIGH VOLTAGE GENERATOR FOR CABLE FAULT LOCATING SWG8-1000

• Voltage Ranges : 0..2kV / 0..4kV / 0..8kV
• Energy : 1000 Joules
• MAx Current Imax : 1400mA / 700mA / 500mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method
• ARM - Arc Reflection Method

 

SEBA SURGEFLEX SFX-32 SPG-32 CABLE FAULT LOCATING SYSTEM

• »» DC-testing up to 32 kV
• »» Prelocating
• - Reflection measurement
• - ARM measurement
• (Arc Reflection Method) up to 32 kV
• - Decay up to 32 kV
• - ICE Impulse Current Method
• 0…4 / 8 / 16 / 32 kV
• »» Burning (fault conditioning) up to 32 kV
• »» Cable tracing (optional)
• »» Pinpointing
• - Distance and acoustic measurement
• 0 … 8 / 16 / 32 kV at 1750 J

 

SEBA KMT T22/13B BURN UNIT FOR TESTING MEDIUM VOLTAGE CABLES T22-13B

• Short circuit proof
• Equipped with new circuity to keep Burn-Down power constant
• Maximal Burn-Down current of 25A
• Burn-Down voltage constinuously variable from 0 to 15 kV
• Indication of output current and voltage
• Integrated start interlock circuit and discharging device
• Pulse mode for earth leakage

 

SEBA KMT OWTS M60 DIELECTRIC DIAGNOSIS AND PARTIAL DISCHARGE MEASURING SYSTEM

• PD diagnosis under oscillating wave test voltage
• PD evaluation possibility and pattern recognition at the nominal voltage level
• Automatic Calibration and Joint location facility
• PD level measurement according to IEC 270 at a bandwidth of 150 ... 650 kHz
• Semi- and fully automatic PD analysing software for defect location with mapping feature
• Calculation of the cable capacitance and the tan delta value
• Simple to use and easy to handle menu-driven unit for operation of the test sequence
• Compact design; low weight

 

SEBA TELEFLEX VX CABLE REFLECTOMETER FOR FAULT LOCATION SYSTEMS

• Range : 20 m … 1280 km
• Bright and large display
• Easiest operation via self guiding and explaining menus
• ARM Slide Technology
• Automatic storage of all results
• Supports all existing prelocation technologies
• Automatic detection and display of cable end and fault position