Code: Seba-KMT PIL-8 Phasenlux
Description
Pil 8
The Phase identification System PIL 8 permits a fast and especially safe phase determination at the jointing location during the mounting of medium voltage cables.
According to DIN VDE 0105 0100 part 2 (EN 50110-1) from Okt. 1997, Pos. 6.2.4.1 Topic 3 (Page 12) it specifies :
"... If the earthing or shorting has to be removed for the duration of measurements or tests, suitable other safety measures have to be taken."
Such safety measures require a relatively large effort and are not always practical. The specific advantage of the technology used in the PIL 8 is the fact, that the ground or shorting must not be removed. In opposition, this grounding it is an essential part of the procedure, which means, the cable must be grounded and shorted for the system to work. Resulting the use is absolutely safe. For each phase the according transceiver clamp are installed tot he grounded cable end and then at the selection point each phase is identified and marked.
Key benefits:
Standard accessories
Scope of delivery
1 pc. Generator/receiver PIL 8
1 set of Cables VL 83-E
3 pairs of Transceiver tongs PIZ 50
1 pc. Transport case PIK 8
Special accessories
for each additional end-to-end measurement (3 are
possible) 3 pairs of transceiver tongs PIZ50
Recommended options
More products SEBAKMT
|
SEBA TELEFLEX T3060 SINGLE-PHASE POWER CABLE REFLECTOMETER T 3060
• Range 8 km, 64 km (for ICE and Decay only) |
|
SEBA SMART THUMP 16 CABLE FAULT LOCATION SYSTEM ON LOW AND MEDIUM VOLTAGE CABLES
• 1500J at 8 / 16 kV, 16 kV DC-HV proof test 23/46mA Burning |
|
SEBA SWG 8-1000 SURGE UNIT HIGH VOLTAGE GENERATOR FOR CABLE FAULT LOCATING SWG8-1000
• Voltage Ranges : 0..2kV / 0..4kV / 0..8kV |
|
SEBA KMT EASYTEST 20KV VFL CABLE TESTER VERY LOW FREQUENCY
• simplified version of the standard VLF test |
|
SEBA KMT T26/1 T26/1A T26/1B T26/1C HIGH VOLTAGE CABLE TESTING
• DC voltages of up to 400 kV and 650 kV |
|
SEBA KMT HPG 70-K 70KV DC HIGH VOLTAGE HIPOT TESTER
• fully insulated test set for DC testing up to 70 kV |
|
SEBA TELEFLEX LV MONITOR CABLE FAULT LOCATION SYSTEM WITH MONITORING MEGGER
• Fault location on live low voltage cables |
|
SEBA KMT MFM 10 CABLE STEATH FAULT LOCATION SYSTEM
• Testing, prelocation and pinpointing of sheath faults |
|
SEBA FAULT SNIFFER FOR DETECTION OF BURNING GASES FROM FAULT CABLES UNDERGROUND
• Customers can stay connected |
|
SEBA KMT VLOCML2 PIPELINE LOCATION AND TRACING FOR UNDERGROUND PIPES AND CABLES
• Location of passive markers which are used by utility |