Seba KMT PIL 8 Phasenlux Phase identi?cation in earthed and short-circuited medium voltage cables

Code: Seba-KMT PIL-8 Phasenlux


 

Datasheet , 0.33 Mb

Description

Pil 8

The Phase identification System PIL 8 permits a fast and especially safe phase determination at the jointing location during the mounting of medium voltage cables. 

According to DIN VDE 0105 0100 part 2 (EN 50110-1) from Okt. 1997, Pos. 6.2.4.1 Topic 3 (Page 12) it specifies 

"... If the earthing or shorting has to be removed for the duration of measurements or tests, suitable other safety measures have to be taken." 

Such safety measures require a relatively large effort and are not always practical. The specific advantage of the technology used in the PIL 8 is the fact, that the ground or shorting must not be removed. In opposition, this grounding it is an essential part of the procedure, which means, the cable must be grounded and shorted for the system to work. Resulting the use is absolutely safe. For each phase the according transceiver clamp are installed tot he grounded cable end and then at the selection point each phase is identified and marked. 

Key benefits:

  • Maintenance free transceiver clamps
  • Suitable for any type of switch gear
  • Requires only one person
  • Easiest operation
  • Absolute safe phase identification

 

 

Standard accessories

Scope of delivery

1 pc. Generator/receiver PIL 8

1 set of Cables VL 83-E

3 pairs of Transceiver tongs PIZ 50

1 pc. Transport case PIK 8

 

Special accessories

for each additional end-to-end measurement (3 are

possible) 3 pairs of transceiver tongs PIZ50

 

Recommended options

 

 

More products SEBAKMT

SEBA SURGEFLEX SFX-40 SPG-40 CABLE FAULT LOCATING SYSTEM

• DC Testing up to 40 kV ARM, ICE and Decay Method integrated
• Operation by VGA Display and single button rotary encoder
• High surge energy fort he acoustic pinpointing 1000 or 2000 J
• Surge voltage levels for MV cablel 0 ... 12,5/25 kV or 0 ... 16/32 kV
• Surge voltage levels for lower voltage 0 ... 3/6 kV or 0 ... 4/8 kV
• Integrated safety system

 

SEBA KMT HV TESTER 25KV HIGH VOLTAGE DC TESTER

• DC output voltage of 0 - 25 kV
• Portable HV Tester
• DC and insulation testing of cables, joints, electrical fixtures, etc.
• High flexibility with built-in battery

 

SEBA KMT BT 500 IS-1 CABLE FAULT CONVERTER

• Overload protection
• Automatic discharge
• Burning of high resistive faults
• Low- potential free voltage avoids damage to other conductors
• Adjustable current limiter

 

SEBA SWG 505 SURGE WAVE GENERATOR FOR FAULT LOCATION IN CABLES SWG505

• Voltage Ranges : 0.. 3kV / 4kV / 5kV
• Energy : 180J / 320J / 500J
• MAx Current Imax : 129mA / 182mA / 213mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method
• ARM - Arc Reflection Method

 

SEBA KMT FERROLUX FLE 10 AUDIO FREQUENCY RECEIVER FOR CABLE LOCATION, SELECTION, SHEATH FAULTS

• Precise direction guidance with right/left arrows
• "SignalSelect" for clear route location
• Depth and signal current intensity measurement at the push of a button
• Route sensor weighs less than 1 kg for non-tiring use
• "DirectSignal" for effective line location

 

SEBA KMT PVS-100 PHASE IDENTIFICATION TESTER FOR CABLE SELECTION

• Identifies the phase at all voltage levels in real time
• Functions with and without a permanent data connection
• Easy to operate
• Eliminates safety risks
• Saves time and money

 

SEBA KMT GEOLUX GL 660-1 EARTH FAULT LOCATOR FOR FAULT LOCATION IN ISOLATED, EARTH FREE SYSTEMS

• Earth fault locator for fault location in isolated, earth free systems
• Mains filter for direct coupling to live cables up to 660 V
• Pulsed output current for easier detection of the test signal
• Filter for the suppression large interference signals
• Location of earth faults up to 150 kOhm
• No switch off during the fault location required
• No influence to the signal lines connected to

 

SEBA KMT KMK 8 COMMUNICATIONS NETWORK CABLE TESTER

• Integrated Reflectometer (TDR)
• Active bridge for high precision R and C measurements and DC and AC fault location
• Measurement by Graaf method in connection with an active slave at the far end
• Passive Wheatstone bridge for R and C measurements and DC and AC fault location
• Test Systems for Pre-measurement, Quick test and Quality testing
• Measurement of interference voltages
• Warning and information system
• Remote control for the operation of the electronic far end loop control switch

 

SEBA T18/5 SURGE WAVE VOLTAGE GENERATOR FOR CABLE FAULT LOCATING

• Voltage Ranges : 0..3kV / 0..6kV / 0..12kV
• Energy : 1000 Joules


SEBA KMT PD SURVEYOR AIR PARTIAL DISCHARGE DETECTOR FOR MEDIUM VOLTAGE CABLES, SWITCHGEAR, PLANTS

• Three PD sensor technologies in one device
•  Early detection of PD activity
•  Universal application - can be applied to
• MV cables, MV switchgear & other types of MV plants
•  Directs maintenance resources straight to the problem areas
•  Easy to use