Surge wave receiver for acoustic and electromagnetic fault pinpointing

 

 

Features

 

·                     Perfect acoustic quality and noise immunity

·                     Automatic mute function to protect your ears

·                     Bright, transflective sun readable display

·                     Easiest handling with automatic adjustment

·                     Earphone volume limitation to 84 dB(A)

 

 

The new digiPHONE+, the new definition of silence!

The innovation for the cable fault pinpointing!

A combination of different technologies for the efficient noise suppression provides you with a maximised, perfect acoustic performance, which passes only the fault noise.

No traffic!

No high heels!

No talking!

You hear only the fault, nothing else -

Your ears will love it!

The technologies of the digiPHONE+

BNR - Background Noise Reduction

The new, intelligent BNR technology with filtering and background noise suppression produces an undisturbed acoustic experience, and lets only the fault sound to your ears.

APM Automatic Proximity Mute

The second silent technology in the new digiPHONE+. As soon as one approaches the handle, the sound switches off, before the hand touches the handle. No cracks or bangs. After removing the hand, a short delay ensures that the digiPHONE+ sensor is standing stable and possible mechanical oscillations have ceased, before the headset is activated.

Housing

The new housing concept of the sensor in connection with a floating microphone suspension reduces the body sound of the sensor itself and provides a solid standing of the digiPHONE+ sensor even on sloped surfaces.

Tracing

The left-right indication keeps the operator always on top of the cable and the compass indicates the fault direction. Distance to fault can be displayed in meter/feet

 

advandages at a glance

                        Easiest Operation

                        Automatic adjustment of values

                        BNR - Background Noise Reduction

                        APM - Auto Proximity Mute when approaching the handle. ("Bang" protection)

                        Bright, sun readable display

                        84 dB(A) limiter (according to noise and vibration protection laws, e.g. "OSHA")

                        Distance measurement in milliseconds or meter/feet

                        Easy tracing with left-right indicator

                        "Compass" for fault direction indication

                        High ground stability of the sensor up to 45°

 

 

Standard accessories

Scope of delivery

                        Receiver Unit DPP-CU with shoulder strap

                        Headset KR22-5

                        Sensor Unit DPP-SU with:

                        Telescopic handle

                        Tips (18 mm and 75 mm), tripod

                        Sensor connection cable

                        Set of batteries

                        Carrying bag with foam inserts

                        Ground plate

                        Manual

 

Accessories

                        Vehicle Installation Kit (instead of the carrying bag)

 

 

Recommended options

 

 

More products SEBAKMT

SEBA KMT VM-810 LOCATION UNDERGROUND PIPES AND CABLES

• Easy to use
• High location accuracy
• Optimal inductive transmission of line signals
• Signal "jumps over" insulating pipe sleeves

 

SEBA KMT CI LCI CABLE IDENTIFIER TEST SET

• Inexpensive cable selection system
• Easy to operate
• Safe handling
• Very small

 

SEBA SWG 8-1000 SURGE UNIT HIGH VOLTAGE GENERATOR FOR CABLE FAULT LOCATING SWG8-1000

• Voltage Ranges : 0..2kV / 0..4kV / 0..8kV
• Energy : 1000 Joules
• MAx Current Imax : 1400mA / 700mA / 500mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method
• ARM - Arc Reflection Method

 

SEBA DIGIPHONE+ ESG NT PINPOINTING ACOUSTIC PINPOINTING SET FOR STEATH FAULT LOCATION IN UNDERGROUND CABLES

• Perfect acoustic quality and noise immunity
• Automatic filtration of interfering signals
• Automatic zero calibration, no adjustments necessary
• History mode
• Acoustic and step voltage fault location in one device
• BNR technology for perfect acoustic quality and noise immunity
• Automatic filtration of interfering signals
• Automatic setting of all parameters, no adjustments necessary

 

SEBA KMT KMK 8 COMMUNICATIONS NETWORK CABLE TESTER

• Integrated Reflectometer (TDR)
• Active bridge for high precision R and C measurements and DC and AC fault location
• Measurement by Graaf method in connection with an active slave at the far end
• Passive Wheatstone bridge for R and C measurements and DC and AC fault location
• Test Systems for Pre-measurement, Quick test and Quality testing
• Measurement of interference voltages
• Warning and information system
• Remote control for the operation of the electronic far end loop control switch

 

SEBA KMT ESG NT PINPOINTING EARTH FAULT LOCATOR IN SHEATH OF UNDERGROUND CABLES

• high accuracy pinpointing of a sheath fault
• Automatic adaptation to voltage level
• Automatic filtration of interfering signals
• Automatic zero calibration, no adjustments necessary
• History mode
• High-contrast color display

 

SEBA KMT EASYTEST 20KV VFL CABLE TESTER VERY LOW FREQUENCY

• simplified version of the standard VLF test
• Easy to operate
• Configurable test sequences
• Compact, rugged and lightweight design
• AC, DC and sheath testing in one single system
• Reporting via USB or Winkis

 

SEBA BPS 5000-D BURN AND PROOF TEST SYSTEM ON MEDIUM VOLTAGE CABLES BPS-5000D BPS500D BPS 5000D-VLF

• Easy-go single button operation
• Protocolling of the test results
• Data transfer via Bluetooth
• DC burn current up to 6 A
• AC burn current up to 110 A
• Sheath fault pinpoiting mode

 

SEBA KMT VFL CR-28..60 VLF TEST SYSTEMS FOR MEDIUM VOLTAGE CABLE TESTING

• VLF CR-28 up to cable series 15 kV
• VLF CR-40 up to cable series 23 kV
• VLF CR-60 up to cable series 35 kV
• VLF, DC and sheath fault testing in one device
• Portable thanks to two-part construction
• High test capacitance
• Integrated discharge system
• Reporting

 

SEBA KMT T22/1 AC HIGH VOLTAGE TESTING SYSTEM

• Compact and lightweight
• Continuous testing with AC voltages up to 75 kVrms at 1 kVA
• Expandable with a second transformer for testing up to 150 kVrms
• Built-in overload protection
• DC testing up to 80 kV with optional rectifier