Seba KMT HPA 100 AC HPA 130 DC Burndown High Voltage Testing

Code: Seba-KMT HPA-100-AC HPA-130-DC


 

Datasheet PDF, 0.6 Mb

Description

HPA 100

The AC Test Set HPA 100 is a powerful test set. The unit has been designed for mounting in cable test van and can be used for testing of cable systems and for burning down high-resistance cable faults with a high breakdown voltage. The test set can be equipped with a rectifier attachment for DC testing up to 130 kV. Since the own noise-level of the test system is below 1 pC, it is also suitable as a voltage source for PD-measurements.

 

Key benefits:

  • Powerful test- and burningsystem
  • Continuous testing with AC voltages up to 100 kVrms at 5 kVA
  • Own noise-level below 1 pC
  • Built-in overcurrent protection
  • DC testing up to 130 kV with optional rectifier

 

 

 

 

 

Standard accessories

 

 

Recommended options

Option
 HGL 130 recti?er for 130 kV DC testing

 

More products SEBAKMT

SEBA KMT HVB-10 10KV CABLE FAULT LOCATION, STEATH TESTING AND PINPOINTING MEGGER HVB10

• Output voltage 0 … 10 kV DC, bi-polar
• Automatic test sequence
• Bi-polar prelocation for the elimination of external influences
• Detection and indication of wrong connections
• Touchscreen and rotary encoder
• Only one HV connection cable
• Completely independent of the parameters of auxiliary lines

 

SEBA TELEFLEX T3060 SINGLE-PHASE POWER CABLE REFLECTOMETER T 3060

• Range 8 km, 64 km (for ICE and Decay only)
• Fully equipped reflectometer with cursor, gain, and range adjustment
• High-contrast 5.7’’ TFT color display (640 x 480 pixel), with LED backlight
• Single-phase ARM input with ICE, Decay and Trigger
• AC or battery operated (up to 3 hours battery life)

 

SEBA KMT T22/13B BURN UNIT FOR TESTING MEDIUM VOLTAGE CABLES T22-13B

• Short circuit proof
• Equipped with new circuity to keep Burn-Down power constant
• Maximal Burn-Down current of 25A
• Burn-Down voltage constinuously variable from 0 to 15 kV
• Indication of output current and voltage
• Integrated start interlock circuit and discharging device
• Pulse mode for earth leakage

 

SEBA KMT VLOC-9800 LINE LOCATION AND TRACER FOR UNDERGROUND PIPES AND CABLES

• Clearly laid out user interface
• Automatic or manual amplification options
• Depth and amperage at the press of a button
• Distance Sensitive Left/Right GuidanceTM
• Sheath fault location (optional)

 

SEBA KMT EZ-THUMP CABLE FAULT LOCATION SYSTEM ON LV/MV CABLES

• Easiest, fully automatic operation
• All in one small and portable unit
• ARM Prelocation
• Pinpointing with 500 J
• Available as 4 or 12 kV version
• Bright, brilliant colour display
• Battery operation

 

SEBA KMT OWTS M60 DIELECTRIC DIAGNOSIS AND PARTIAL DISCHARGE MEASURING SYSTEM

• PD diagnosis under oscillating wave test voltage
• PD evaluation possibility and pattern recognition at the nominal voltage level
• Automatic Calibration and Joint location facility
• PD level measurement according to IEC 270 at a bandwidth of 150 ... 650 kHz
• Semi- and fully automatic PD analysing software for defect location with mapping feature
• Calculation of the cable capacitance and the tan delta value
• Simple to use and easy to handle menu-driven unit for operation of the test sequence
• Compact design; low weight

 

SEBA KMT VIVAX METROTECH VLOC2 LINE LOCATION AND TRACER FOR UNDERGROUND PIPES AND CABLES

• Carbon-reinforced plastic housing
• Protection class IP 54 for use in any weather conditions
• Colour display
• High-speed processor
• Several location modes with orientation using a compass
• A large number of available frequencies
• Depth/amperage at the press of a button or sustained

 

SEBA KMT CI LCI CABLE IDENTIFIER TEST SET

• Inexpensive cable selection system
• Easy to operate
• Safe handling
• Very small

 

SEBA KMT HPA35 HPA50 HPA58 HPA78 AC HIGH VOLTAGE HIPOT TESTING WITHSTANDING

• HPA 35, AC testing up to 35 kVrms
• HPA 50 / 58 AC testing up to 50 / 58 kVrms
• HPA 78, AC testing up to 78 kVrms

 

SEBA KMT FERROLUX FLE 10 AUDIO FREQUENCY RECEIVER FOR CABLE LOCATION, SELECTION, SHEATH FAULTS

• Precise direction guidance with right/left arrows
• "SignalSelect" for clear route location
• Depth and signal current intensity measurement at the push of a button
• Route sensor weighs less than 1 kg for non-tiring use
• "DirectSignal" for effective line location