Seba KMT vLoc-5000 Line Location and Tracer for Underground Pipes and Cables

Code: Seba-KMT vLoc-5000


 

Datasheet PDF, 1.33 Mb

Description

vLoc-5000

The new vLoc-5000 from SebaKMT is the most state-of-the-art line location system on the market. It includes several functions that facilitate your daily location work and makes the results more reliable and informative. 

The centrepiece of the vLoc-5000 line location system is the multi-frequency receiver. The main task of the receiver of a line location system is to give precise information on the position of the target conductor, in particular the location and the depth. However, problems occur repeatedly during the line location process, e.g. field distortions caused by discharge or the coupling of neighbouring lines. 

Special features:

  • Precise direction guidance with right/left arrows and guidance compass
  • SiS ("Signal Select") and SD ("Signal Direction") for reliable line identification
  • "Distortion Alert" for signal evaluation
  • Internal GPS receiver and data storage
  • Permanent depth or signal current intensity measurement

 

 

Standard accessories

 

 

Recommended options

 

 

More products SEBAKMT

SEBA KMT VFL CR-80 46KV HIGH VOLTAGE CABLE TEST SYSTEMS

• Powerful 0.1 Hz VLF test system
• High test power without frequency reduction
• No polarisation effects as by DC testing
• Protocoling
• Breakdown recognition
• Leakage current measurement

 

SEBA SFX 5-1000 SPG 5-1000 CABLE FAULT LOCATION SYSTEM ON LOW AND MEDIUM VOLTAGE CABLES

• ICEplus for the easy and reliable fault prelocation without interference from branches
• High surge energy for pinpointing
• Compact and lightweight construction
• Testing up to 5 kV
• Automatic detection of the breakdown voltage
• Pinpointing with the integrated surge generator 0 … 2 / 4 kV 1000 J
• Pulsed DC for sheath fault pinpointing

 

SEBA SURGEFLEX SFX-15 SFX-25 CABLE FAULT LOCATING SYSTEM

• » DC-Testing up to 15 kV / 25 kV (depending on model)
• » Prelocating
• » - Reflection measurement
• » - ARM-Measurement (Arc reflection method)
• » - ICE Impulse current method
• » Cable tracing (optional)
• » Pin-pointing
• » - Distance and acoustic measurement
• » - Audio frequency methods (optional)
• » Battery and mains operation

 

SEBA KMT VFL SINUS 54KV SINE WAVE CABLE TEST SYSTEMS

• High test capacity of 5 µF
• Single-button operation "easyGo"
• Continuous duty cycle
• Integrated safety system
• Suitable for diagnosing 45 kV rated cables

 

SEBA KMT HPG 50..110-H DC & AC HIGH VOLTAGE CABLE TESTING SETS

• HPG 50-H, AC testing up to 35 kVRMS / DC-testing up to 50 kV
• HPG 70 / 80-H, AC testing up to 50 / 58 kVRMS / DC-testing up to 70 / 80 kV
• HPG 110-H, AC testing up to 78 kVRMS / DC-testing up to 110 kV
• Suitable for AC-testing and DC-testing
• Compact, cast-resin high-voltage transformers
• Separate control and HV-units
• Voltage continuously adjustable
• Powerful system: 1,2 kVA continuous operation, up to 3 kVA 60 min. short-time operation

 

SEBA KMT OWTS M60 DIELECTRIC DIAGNOSIS AND PARTIAL DISCHARGE MEASURING SYSTEM

• PD diagnosis under oscillating wave test voltage
• PD evaluation possibility and pattern recognition at the nominal voltage level
• Automatic Calibration and Joint location facility
• PD level measurement according to IEC 270 at a bandwidth of 150 ... 650 kHz
• Semi- and fully automatic PD analysing software for defect location with mapping feature
• Calculation of the cable capacitance and the tan delta value
• Simple to use and easy to handle menu-driven unit for operation of the test sequence
• Compact design; low weight

 

SEBA T18/5 SURGE WAVE VOLTAGE GENERATOR FOR CABLE FAULT LOCATING

• Voltage Ranges : 0..3kV / 0..6kV / 0..12kV
• Energy : 1000 Joules


SEBA KMT PIL 8 PHASENLUX PHASE IDENTI?CATION IN EARTHED AND SHORT-CIRCUITED MEDIUM VOLTAGE CABLES

• Maintenance free transceiver clamps
• Suitable for any type of switch gear
• Requires only one person
• Easiest operation
• Absolute safe phase identification


SEBA SWG 1750 SURGE WAVE GENERATOR FOR FAULT LOCATION IN CABLES SWG1750 SWG1750C SWG1750CI SWG1750C-4 SWG1750CD

• Voltage Ranges : 0.. 8kV / 0..16kV / 0..32kV
• SWG 1750C with 8 - 16 - 32 kV / 1750 J
• SWG 1750 CI with 8 - 16 - 32 kV / 1750 J, incl. leakage current measurement
• SWG 1750 C-4 with 2 - 4 kV / 1150 J and 8 - 16 - 32 kV / 1750 J
• SWG 1750 CD with 8 - 16 - 32 kV / 3500 J

 

SEBA TELEFLEX-VX ADAPTER FOR SAFE OPERATION OF REFLECTOMETERS ON OVERHEAD LINES

• Very easy to operate
• Very good resolution, for both near and distant ranges
• Dangerous induction voltages reliably discharged
• Connection to a measurement system
• Test pulses up to 1,500 V for long distances
• For distances over 2,000 km