Seba KMT vLoc-5000 Line Location and Tracer for Underground Pipes and Cables

Code: Seba-KMT vLoc-5000


 

Datasheet PDF, 1.33 Mb

Description

vLoc-5000

The new vLoc-5000 from SebaKMT is the most state-of-the-art line location system on the market. It includes several functions that facilitate your daily location work and makes the results more reliable and informative. 

The centrepiece of the vLoc-5000 line location system is the multi-frequency receiver. The main task of the receiver of a line location system is to give precise information on the position of the target conductor, in particular the location and the depth. However, problems occur repeatedly during the line location process, e.g. field distortions caused by discharge or the coupling of neighbouring lines. 

Special features:

  • Precise direction guidance with right/left arrows and guidance compass
  • SiS ("Signal Select") and SD ("Signal Direction") for reliable line identification
  • "Distortion Alert" for signal evaluation
  • Internal GPS receiver and data storage
  • Permanent depth or signal current intensity measurement

 

 

Standard accessories

 

 

Recommended options

 

 

More products SEBAKMT

SEBA TELEFLEX-VX ADAPTER FOR SAFE OPERATION OF REFLECTOMETERS ON OVERHEAD LINES

• Very easy to operate
• Very good resolution, for both near and distant ranges
• Dangerous induction voltages reliably discharged
• Connection to a measurement system
• Test pulses up to 1,500 V for long distances
• For distances over 2,000 km

 

SEBA KMT HPG 50..80-D DC & AC HIGH VOLTAGE CABLE TESTER

• HPG 50-D, AC testing up to 35 kVRMS/ DC testing up to 100 kV
• HPG 70 / 80-D, AC testing up to 50 / 58 kVRMS / DC testing up to 140 / 150 kV
• Suitable for AC testing and DC testing
• Compact, cast-resin high-voltage transformers
• Separate control and HV-units
• Voltage continuously adjustable
• Powerful system: 1,2 kVA continuous operation, up to 3 kVA 60 min. short-time operation

 

SEBA KMT VFL CR-28..60 VLF TEST SYSTEMS FOR MEDIUM VOLTAGE CABLE TESTING

• VLF CR-28 up to cable series 15 kV
• VLF CR-40 up to cable series 23 kV
• VLF CR-60 up to cable series 35 kV
• VLF, DC and sheath fault testing in one device
• Portable thanks to two-part construction
• High test capacitance
• Integrated discharge system
• Reporting

 

SEBA TELEFLEX VX CABLE REFLECTOMETER FOR FAULT LOCATION SYSTEMS

• Range : 20 m … 1280 km
• Bright and large display
• Easiest operation via self guiding and explaining menus
• ARM Slide Technology
• Automatic storage of all results
• Supports all existing prelocation technologies
• Automatic detection and display of cable end and fault position

 

SEBA KMT VM-850 LOCATION UNDERGROUND PIPES AND CABLES

• Easy to use
• High location accuracy
• Optimal inductive transmission of line signals
• Classic design, compact and light

 

SEBA KMT EASYTEST 20KV VFL CABLE TESTER VERY LOW FREQUENCY

• simplified version of the standard VLF test
• Easy to operate
• Configurable test sequences
• Compact, rugged and lightweight design
• AC, DC and sheath testing in one single system
• Reporting via USB or Winkis

 

SEBA KMT T22/1 AC HIGH VOLTAGE TESTING SYSTEM

• Compact and lightweight
• Continuous testing with AC voltages up to 75 kVrms at 1 kVA
• Expandable with a second transformer for testing up to 150 kVrms
• Built-in overload protection
• DC testing up to 80 kV with optional rectifier

 

SEBA KMT SEBALOG N-3 AUTOMATIC WATER LEAK LOCATION WITH CORRELATING NOISE LOGGER NETWORK

• Latest measured data available every day
• Correlation function
• No time-consuming driving past individual loggers
• Remote configuration
• Very simple installation process
• Cost-effective data transmission

 

SEBA KMT EZ-THUMP CABLE FAULT LOCATION SYSTEM ON LV/MV CABLES

• Easiest, fully automatic operation
• All in one small and portable unit
• ARM Prelocation
• Pinpointing with 500 J
• Available as 4 or 12 kV version
• Bright, brilliant colour display
• Battery operation

 

SEBA KMT VFL CR-80 46KV HIGH VOLTAGE CABLE TEST SYSTEMS

• Powerful 0.1 Hz VLF test system
• High test power without frequency reduction
• No polarisation effects as by DC testing
• Protocoling
• Breakdown recognition
• Leakage current measurement