Multifunction Electrical Installation Tester Chauvin Arnoux CA6116

Code: Chauvin Arnoux CA6116


 

Datasheet PDF, 2.56 Mb

Description

The C.A 6116 is an ALL-IN-ONE tool for electrical installation testing in compliance with the national and international standards (IEC 60364-6, NF C 15-100, VDE 100, XP C 16-600, etc). It combines design, ergonomics, simplicity, rapidity and accuracy. Suitable for all types of neutral systems (TT, TN, IT), it can be used in all the main sectors:

industry, tertiary and housing.

Rugged and compact, the C.A 6116 is specially designed to be quick and effective to learn. On the large backlit graphic screen, the user can view all the essential results at a glance.

A rotary switch on the instrument's front panel gives direct access to all the functions. A wide range of audible alarms and visual symvbols are available for quick interpretation of the results according to the standards.

The contextual help for each function guides users step-by-step or only when needed. The high-performance C.A 6116 offers excellent measurement stability, including in disturbed industrial environments. With the C.A 6116, users can prepare their measurement campaigns directly in the measurement instrument or via the PC

software supplied. This function allows hierarchical storage on the basis of the site, the location and the equipment tested.

Delivered in a carrying bag with a large number of accessories, the standard version also includes a wrist-strap and a 4-point harness for "hands-free" use.

 

Standard accessories

C.A 6116 (EURO version)½ ½½ P01145450

C.A 6116 (GB version)½½½½ P01145450A

C.A 6116 (IT version)½½½½½ P01145450B

C.A 6116 (CH version)½½½½ P01145450C

C.A 6116 (US version)½½½½½ P01145450D

 

 
C.A 6116 tester delivered with

1 USB cable,

1 three-pin/mains lead,

1 three-pin lead / 3 safety leads,

3 test probes (½ 4 mm),

3 crocodile clips,

2 straight/elbowed safety leads (3 m),

remote-control probe,

mains power pack,

wrist strap,

4-point strap for extra comfort,

carrying bag,

data export software,

5 safety connectors and 5 operating manuals (1 per language).

 

Recommended options

 

15 m earth kit (red / blue / green)½½P01102017

50 m earth kit½½½½½½½½ P01102021

100 m earth kit½ ½½½½½½ P01102022

1P 30 m black earth kit½½½½ P01102018

C177 clamp½ ½½½½½½½½ P01120335

C177A clamp½ ½½½½½½½ P01120336

MN77 earth kit½ ½½½½½½ P01120460

Continuity pole½ ½½½½½½ P01102084

DataView½½½½½½½½½½ P01102095

Battery pack½½½½½½½½½ P01296024

USB lead½ ½½½½½½½½½ P01295293

PA 30 W mains power pack½½ P01102057

Screen-protection film½ ½½½ P01102094

4-point strap½½½½½½½½ P01298073

Carrying bag½½½½½½½½ P01298056

 

More products CHAUVIN ARNOUX

DIGITAL INSULATION MEGOHMMETER 1KV CHAUVIN ARNOUX CA6525

• insulation: up to 2G? at 250V, 500V and 1,000V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep and compensation of leads)
• resistance: 0 to 400k?
• giant 4,000-count display + bargraph


SOLAR PANEL EFFICIENCY TESTER CHAUVIN ARNOUX FTV100 GREENTEST

• electrical power survey
• Calculation of solar panel efficiency
• Calculation of inverter efficiency
• Voltage up to 1,000 VDC / 600 VAC
• Current up to 1,400 ADC / 3,000 AAC
• AC/DC power: 20,000 WDC / 1,200 WAC

 

THREE-PHASE ENERGY QUALITY ANALYZER CHAUVIN-ARNOUX CA8334B QUALISTAR

• Complete three-phase analysis:
• - voltage, current,
• - power / energy,
• - harmonics (up to 50th order), flicker,
• - measurement of transients,
• - alarm trigger...
• Processing of data via PC software QualistarView or DataViewer Pro.
• Recording of 12 screens
• Compliant with IEC 61010-1, 600V Cat.IV

 

DIGITAL INSULATION MEGOHMMETER 100V CHAUVIN ARNOUX CA6531

• insulation: up to 400MO at 50V and 100V
• AC voltage measurement: 0 to 400V
• voltage indication before measurement of insulation: 0 to 600V AC/DC (blocking if U>25V)
• resistance: 0 to 40kO
• capacity: 0 to 4000nF
• current: 0 to 400mA AC/DC


INSULATION MEGOHMETER 1KV CHAUVIN ARNOUX CA6543

• insulation: up to 4TO (5 cal.) at 50/100/250/500 and 1,000V DC
• automatic calculation of insulation quality ratios: DAR and PI
• programmable test period and plottingof the R(t) curve
• automatic indication of voltage before and after measurement: 1 to 1,000V AC/DC
• resistance: 0.01O to 400kO
• continuity: 0.01O to +40O (audible beep and lead compensation )

 

MULTIFUNCTION ELECTRICAL INSTALLATION TESTER CHAUVIN ARNOUX CA6116

• ALL-IN-ONE tool for electrical installation testing
• compliance with the national and international standards (IEC 60364-6, NF C 15-100, VDE 100, XP C 16-600...
• design, ergonomics, simplicity, rapidity and accuracy
• Suitable for all types of neutral systems (TT, TN, IT)
• large backlit graphic screen

 

THREE-PHASE POWER QUALITY ANALYZER CHAUVIN-ARNOUX CA8332B QUALISTAR

• Complete three-phase analysis:
• - voltage, current,
• - power / energy,
• - harmonics (50th rank), flicker,
• - alarm trigger...
• Processing of data with DataView PC software.
• Working memory: 2MB

 

MEGOHMMETER 15KV CHAUVIN ARNOUX CA6555

• Wide measurement range from 10 kohm to 30 Tohm
• Fixed or programmable test voltage from 40V to 15 kV
• 5mA max. charging current
• Large backlit LCD screen with digital display, bargraph and R(t)+u(t), i(t) and i(u) graphs
• Automatic ratio calculation: DAR / PI / DD / DR (ppm/V)
• Multiple test modes: voltage ramp and step with "burning", "early break" and "I-limit" modes

 

MULTIFUNCTION ELECTRICAL MACHINE TESTER CHAUVIN ARNOUX CA6155

• Measurements in compliance with the IEC 60204 Ed.5 / VDE701/702 / IEC 61439 (IEC 60439) standards
• 200 mA and 10 A continuity measurements
• Insulation resistance at 250 VDC and 500 VDC
• Dielectric test at 1,000 V / 1,890 V / 2,500 V
• Leakage current measurement by substitution method
• Differential leakage current
• Contact leakage current
• Mains power-lead polarity test

 

EARTH GROUND RESISTANCE TESTER ON PYLONS CHAUVIN ARNOUX CA6472

• 5 tools in 1 with this tester
• extensive measurement ranges: 0.001?to 100 k?
• analysing the frequency behaviour of the earthing systems (from 41 Hz to 5 kHz)
• high-level, expert calculation capabilities
• IP 53 leakproofing