Multifunction Electrical Machine Tester Chauvin Arnoux CA6155

Code: Chauvin Arnoux CA6155


 

Datasheet PDF, 1.21 Mb

Description

The multi-function C.A 6155 can be used for all the measurements required to test the electrical safety of portable electrical equipment, machines and switchgear.

 

It provides a wide range of fully-compliant measurements:

- Measurements in compliance with the IEC 60204

Ed.5 / VDE701/702 / IEC 61439 (IEC 60439) standards

- 200 mA and 10 A continuity measurements

- Insulation resistance at 250 VDC and 500 VDC

- Dielectric test at 1,000 V / 1,890 V / 2,500 V

- Leakage current measurement by substitution method

- Differential leakage current

- Contact leakage current

- Mains power-lead polarity test

- Functional test with consumption measurement

- TRMS leakage and load current measurements (current clamp available as option)

- RCD test (including portable RCDs)

- Loop impedance and line impedance measurement with calculation of short-circuit currents

- Discharge time

- Phase rotation

- Voltage / frequency measurements

- Functional and visual inspections.

 

Standard accessories

C.A 6155. . .. . . . . . . . P01146001

Delivered with an accessories bag containing:

- 1 high-voltage test probe

- 1 mains-socket test cable

- 1 test cable with separate wires

- 1 red lead 1.5 m long

- 1 black lead 1.5 m long

- 1 green lead 1.5 m long

- 1 red lead 4 m long

- 4 test probes

- 3 crocodile clamps

- 1 operating manual in 5 languages

- 1 USB communication cable

- 1 RS232 communication cable

- Data transfer software

 

Recommended options

 

 

More products CHAUVIN ARNOUX

ELECTRICAL MACHINE CERTIFICATION TESTER CHAUVIN ARNOUX CA6160

• dielectric test: standard measurement modes (Un from 100 to 5,000V with Ilim 500mA) and programmed modes (t1, t2, t3, U1, U2)
• continuity: up to 100O with 0.1 < ITEST < 25A
• voltage drop: up to 100V (Itest > 10A)
• insulation resistance: up to 1GO at 250/500VDC and 1,000VDC
• measurement of internal and external discharge time (at the plug)
• leakage current: operating and residual up to 20mA, contact up to 2mA
• functional testing: voltage, current, frequency and power

 

DIGITAL INSULATION MEGOHMMETER 500V CHAUVIN ARNOUX CA6533

• insulation: up to 20G? at 50V, 100V, 250V and 500V
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• resistance: 0 to 400kO
• giant 4,000-count display + bargraph
• backlit display
• programmable alarms


ENERGY POWER ANALYZER AND MOTOR DIAGNOSTIC TESTER CHAUVIN-ARNOUX CA8220

• Voltage and current with instant display
• TRMS AC+DC value
• peak values and THD
• Short-term flicker measurement
• offers instant display of the waveform
• comprehensive power and energy analysis on both single-phase and three-phase systems
• Up to several days½ recording
• Customization of alarm settings

 

EARTHING RESISTANCE TESTER CHAUVIN ARNOUX CA6470N TERCA3

• extensive measurement ranges: 0.001? to 100 k?
• adjustment of the measurement frequency between 41 Hz and 512 Hz
• 10 times greater accuracy due to its 4-pole measurement method
• measuring soil resistivity
• calculate r automatically by the Wenner or Schlumberger methods

 

INSULATION RESISTANCE MEGOHMMETER 1KV CHAUVIN ARNOUX CA6541

• insulation: up to 4TO (5 cal.) at 50/100/250/500 and 1,000V DC
• automatic calculation of insulation quality ratios: DAR and PI
• programmable test period and plotting of the R(t) curve (automatic memorisation of 20 samples)
• automatic indication of voltage before and after measurement: 1 to 1000V AC/DC
• resistance: from 0.01O to 400kO
• continuity: 0.01O to +40O (audible beep and lead compensation)
• automatic measurement capacity after each insulation measurement: 0.005 to 4.999 ½F

 

THREE-PHASE POWER QUALITY ANALYZER CHAUVIN-ARNOUX CA8435

• C.A 8435, the rugged, waterproof IP67
• Indoor and outdoor use, even when it is raining
• 5 voltage inputs, 4 current inputs
• Continuous recording of all the parameters simultaneously
• Monitoring with alarms
• All types of installations
• Measurement of P, Q, S and D power values (total and per phase)
• Calculation of Pst & Plt flicker values

 

THREE-PHASE POWER QUALITY ANALYZER CHAUVIN-ARNOUX CA8332B QUALISTAR

• Complete three-phase analysis:
• - voltage, current,
• - power / energy,
• - harmonics (50th rank), flicker,
• - alarm trigger...
• Processing of data with DataView PC software.
• Working memory: 2MB

 

DIGITAL INSULATION MEGOHMMETER 1KV CHAUVIN ARNOUX CA6525

• insulation: up to 2G? at 250V, 500V and 1,000V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep and compensation of leads)
• resistance: 0 to 400k?
• giant 4,000-count display + bargraph


SOLAR PHOTOVOLTAIC PANELS TESTER CHAUVIN ARNOUX FTV200

• I-V curve with cursor
• Voltage measurement up to 1,000 VDC
• Current measurement up to 10 ADC
• Pyranometer up to 2,000 W/m2
• Mesure of r½sistance Rs
• 80 MB internal storage capacity
• More than 10,000 different panel references
• Possibility of external USB key for storage

 

TRANFORMER RATIO TESTER CHAUVIN ARNOUX DTR8510

• calculate the ratios
• NiMH battery life of up to 10 hours
• Automatic calibration and balancing
• Low-voltage test
• Digital display ½ display of ratios, winding direction - % deviation
• Degauss function