Digital Insulation Megohmmeter 100V Chauvin Arnoux CA6531

Code: Chauvin Arnoux CA6531


 

Description

Perfectly suitable for tests on telephone lines or electronic equipment, the C.A 6531 megohmmeter measures insulation at 50V and 100V as well as resistances, current capacity and AC/DC voltage.

 

  • insulation: up to 400MO at 50V and 100V
  • AC voltage measurement: 0 to 400V
  • voltage indication before measurement of insulation: 0 to 600V AC/DC (blocking if U>25V)
  • resistance: 0 to 40kO
  • capacity: 0 to 4000nF
  • current: 0 to 400mA AC/DC
  • giant, 4000-count display + bargraph (simultaneous reading of the measurement and analogue variation)
  • backlit display
  • programmable alarms
  • DREL function for testing for the presence of transmission frame or measurement of the resistance difference of 2 wires of a pair
  • direct display in km of the length of the line being tested
  • remote control probe (option)
  • back stand for use on a table or on the ground
  • high autonomy: 6 b

 

 

 

Standard accessories

C.A 6531...................P01140804B

C.A 6533...................P01140805

 

½ 1 "hands-free" carrying case

½ 1 pair of 1.5 m leads, red + black

(the leads on C.A 6533 are guarded)

½ 1 red croc-clip

½ 1 black test probe

½ 2 wire grips, red + black

½ 6 LR6 batteries

½ 1 set of operating instructions.

* + 1 blue 1.5 m lead and 1 blue croc-clip for model C.A 6533

 

More products CHAUVIN ARNOUX

THREE-PHASE ENERGY QUALITY ANALYZER CHAUVIN-ARNOUX CA8334B QUALISTAR

• Complete three-phase analysis:
• - voltage, current,
• - power / energy,
• - harmonics (up to 50th order), flicker,
• - measurement of transients,
• - alarm trigger...
• Processing of data via PC software QualistarView or DataViewer Pro.
• Recording of 12 screens
• Compliant with IEC 61010-1, 600V Cat.IV

 

ENERGY POWER ANALYZER AND MOTOR DIAGNOSTIC TESTER CHAUVIN-ARNOUX CA8220

• Voltage and current with instant display
• TRMS AC+DC value
• peak values and THD
• Short-term flicker measurement
• offers instant display of the waveform
• comprehensive power and energy analysis on both single-phase and three-phase systems
• Up to several days½ recording
• Customization of alarm settings

 

INSULATION MEGOHMETER 1KV CHAUVIN ARNOUX CA6543

• insulation: up to 4TO (5 cal.) at 50/100/250/500 and 1,000V DC
• automatic calculation of insulation quality ratios: DAR and PI
• programmable test period and plottingof the R(t) curve
• automatic indication of voltage before and after measurement: 1 to 1,000V AC/DC
• resistance: 0.01O to 400kO
• continuity: 0.01O to +40O (audible beep and lead compensation )

 

ELECTRICAL MACHINE CERTIFICATION TESTER CHAUVIN ARNOUX CA6160

• dielectric test: standard measurement modes (Un from 100 to 5,000V with Ilim 500mA) and programmed modes (t1, t2, t3, U1, U2)
• continuity: up to 100O with 0.1 < ITEST < 25A
• voltage drop: up to 100V (Itest > 10A)
• insulation resistance: up to 1GO at 250/500VDC and 1,000VDC
• measurement of internal and external discharge time (at the plug)
• leakage current: operating and residual up to 20mA, contact up to 2mA
• functional testing: voltage, current, frequency and power

 

DIGITAL INSULATION MEGOHMMETER 1000V CHAUVIN ARNOUX CA6523

• insulation: up to 2G? at 500V and 1,000V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep and compensation of leads)
• resistance: 0 to 400k?
• giant 4,000-count display + bargraph


INSULATION RESISTANCE MEGOHMMETER 1KV CHAUVIN ARNOUX CA6541

• insulation: up to 4TO (5 cal.) at 50/100/250/500 and 1,000V DC
• automatic calculation of insulation quality ratios: DAR and PI
• programmable test period and plotting of the R(t) curve (automatic memorisation of 20 samples)
• automatic indication of voltage before and after measurement: 1 to 1000V AC/DC
• resistance: from 0.01O to 400kO
• continuity: 0.01O to +40O (audible beep and lead compensation)
• automatic measurement capacity after each insulation measurement: 0.005 to 4.999 ½F

 

THREE-PHASE ENERGY ANALYZER CHAUVIN-ARNOUX CA8335 QUALISTAR PLUS

• - Voltage ratios: 1 V to 500 kV
• - Mixed sensors: 10 mA to 60 kA depending on sensor
• for quick verification of network quality and simple processing of the results

 

EARTH GROUND RESISTANCE TESTER ON PYLONS CHAUVIN ARNOUX CA6474

• Ideal for earth measurements on pylons
• measurement range: 0.001 O to 99.99 kO
• resolution: 0.001 to 10 O
• no-load voltage: 16 or 32 VRMS
• measurement frequency: 41 Hz to 5,018 Hz
• measurement of resistance of earth stakes: 0.01 O to 100kO
• leakproofing: IP53

 

SOLAR PHOTOVOLTAIC PANELS TESTER CHAUVIN ARNOUX FTV200

• I-V curve with cursor
• Voltage measurement up to 1,000 VDC
• Current measurement up to 10 ADC
• Pyranometer up to 2,000 W/m2
• Mesure of r½sistance Rs
• 80 MB internal storage capacity
• More than 10,000 different panel references
• Possibility of external USB key for storage

 

EARTHING RESISTANCE TESTER CHAUVIN ARNOUX CA6471

• extensive measurement ranges: 0.001? to 100 k?
• adjustment of the measurement frequency between 41 Hz and 512 Hz
• 10 times greater accuracy due to its 4-pole measurement method
• measuring soil resistivity
• calculate r automatically by the Wenner or Schlumberger methods
• Ergonomic, comprehensive and accurate