Digital Insulation Megohmmeter 100V Chauvin Arnoux CA6531

Code: Chauvin Arnoux CA6531


 

Description

Perfectly suitable for tests on telephone lines or electronic equipment, the C.A 6531 megohmmeter measures insulation at 50V and 100V as well as resistances, current capacity and AC/DC voltage.

 

  • insulation: up to 400MO at 50V and 100V
  • AC voltage measurement: 0 to 400V
  • voltage indication before measurement of insulation: 0 to 600V AC/DC (blocking if U>25V)
  • resistance: 0 to 40kO
  • capacity: 0 to 4000nF
  • current: 0 to 400mA AC/DC
  • giant, 4000-count display + bargraph (simultaneous reading of the measurement and analogue variation)
  • backlit display
  • programmable alarms
  • DREL function for testing for the presence of transmission frame or measurement of the resistance difference of 2 wires of a pair
  • direct display in km of the length of the line being tested
  • remote control probe (option)
  • back stand for use on a table or on the ground
  • high autonomy: 6 b

 

 

 

Standard accessories

C.A 6531...................P01140804B

C.A 6533...................P01140805

 

½ 1 "hands-free" carrying case

½ 1 pair of 1.5 m leads, red + black

(the leads on C.A 6533 are guarded)

½ 1 red croc-clip

½ 1 black test probe

½ 2 wire grips, red + black

½ 6 LR6 batteries

½ 1 set of operating instructions.

* + 1 blue 1.5 m lead and 1 blue croc-clip for model C.A 6533

 

More products CHAUVIN ARNOUX

ENERGY POWER ANALYZER CHAUVIN-ARNOUX CA8230

• Voltage range: 6VRMS to 600VRMS AC+DC
• AC current range: 5mA to 6,500A
• DC current range: 1A to 1,700A
• Values: Min., Max., Avg., Peak (+/-), CF
• Power: W, VA, var, DF, THD, cos f, tan f
• Energy: Wh, VAh, varh
• Harmonics: up to the 50th order
• IEC1010/EN61010: Cat.III-600V

 

EARTH RESISTANCE TESTER CHAUVIN ARNOUX CA6421

• earth resistance: 0.5Oat 1,000 O (log scale) )
• 3 fault presence indicators to validate the measurement
• measurement frequency: 128Hz
• connection of rods to colour-coded terminals
• removable captive connection strip between S and H for 2-wire resistance measurements


ELECTRICAL MACHINE CERTIFICATION TESTER CHAUVIN ARNOUX CA6160

• dielectric test: standard measurement modes (Un from 100 to 5,000V with Ilim 500mA) and programmed modes (t1, t2, t3, U1, U2)
• continuity: up to 100O with 0.1 < ITEST < 25A
• voltage drop: up to 100V (Itest > 10A)
• insulation resistance: up to 1GO at 250/500VDC and 1,000VDC
• measurement of internal and external discharge time (at the plug)
• leakage current: operating and residual up to 20mA, contact up to 2mA
• functional testing: voltage, current, frequency and power

 

DIGITAL INSULATION MEGOHMMETER 500V CHAUVIN ARNOUX CA6521

• insulation: up to 2G? at 250V and 500V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep)
• giant 400-count display + bargraph (simultaneous reading of measurement and analogue variance)
• back stand for use on a table or on the ground
• long battery life: 6 x 1.5V batteries


DIGITAL INSULATION MEGOHMMETER 5KV CHAUVIN ARNOUX CA6547

• wide range from 30k? to 10T? !
• 4 fixed test voltages: 500 / 1,000 / 2500 and 5,000V
• programmable test voltage position: from 40 to 5,100V in increments of 10V or 100V
• giant backlit LCD screen with digital display + bargraph
• qualitative analysis of insulation: automatic calculation of DAR, PI and DD (dielectric discharge) ratios
• plotting of the R(t) curve

 

TRANFORMER RATIO TESTER CHAUVIN ARNOUX DTR8510

• calculate the ratios
• NiMH battery life of up to 10 hours
• Automatic calibration and balancing
• Low-voltage test
• Digital display ½ display of ratios, winding direction - % deviation
• Degauss function

 

INSULATION MEGOHMETER 1KV CHAUVIN ARNOUX CA6543

• insulation: up to 4TO (5 cal.) at 50/100/250/500 and 1,000V DC
• automatic calculation of insulation quality ratios: DAR and PI
• programmable test period and plottingof the R(t) curve
• automatic indication of voltage before and after measurement: 1 to 1,000V AC/DC
• resistance: 0.01O to 400kO
• continuity: 0.01O to +40O (audible beep and lead compensation )

 

EARTH GROUNDING RESISTANCE TESTER CHAUVIN ARNOUX CA6462

• 3-in-1 tester: resistivity, earth, coupling
• measurement range: 0.00 to 2,000? (3 automatic calibres)
• change from 4-wire method to 3-wire method thanks to 1 removable captive bar between E and ES
• 3 fault presence indicators to validate measurement
• measurement frequency: 128Hz

 

EARTH RESISTANCE DIGITAL TESTER CHAUVIN ARNOUX CA6423

• earth resistance: 0.00 to 2,000O (3 cal.)
• 3 fault presence indicators to validate the measurement
• measurement frequency: 128Hz
• connection of rods to colour-coded terminals
• a removable captive connection strip between H and S for measurement of 2-wire resistance
• large 2,000-count digital display with 18mm digits: excellent readability


ENERGY POWER ANALYZER AND MOTOR DIAGNOSTIC TESTER CHAUVIN-ARNOUX CA8220

• Voltage and current with instant display
• TRMS AC+DC value
• peak values and THD
• Short-term flicker measurement
• offers instant display of the waveform
• comprehensive power and energy analysis on both single-phase and three-phase systems
• Up to several days½ recording
• Customization of alarm settings