The C.A 6541 is a high-performance 50V to 1kV insulation tester; it supports the most demanding site conditions and is ideal for qualitative insulation analysis.

 

  • insulation: up to 4TO (5 cal.) at 50/100/250/500 and 1,000V DC
  • automatic calculation of insulation quality ratios: DAR and PI
  • programmable test period and plotting of the R(t) curve (automatic memorisation of 20 samples)
  • automatic indication of voltage before and after measurement: 1 to 1000V AC/DC
  • resistance: from 0.01O to 400kO
  • continuity: 0.01O to +40O (audible beep and lead compensation)
  • automatic measurement capacity after each insulation measurement: 0.005 to 4.999 ½F
  • microprocessor-controlled
  • giant LCD screen with digital display + bargraph
  • backlit display
  • SMOOTH function (smoothing of values displayed)
  • insulation test voltages can be locked
  • programmable alarms

½          long battery life: 8 x LR14 batteries (21,000 insulation tests of 5s each)

½          remote control probe available as an option

½          electrical security: IEC 61010-1 + A2 ½ Cat. III - 600V and IEC 61557

½          dimensions: 240 x 185 x 110mm; weight: 3.4kg

 

 

 

Standard accessories

C.A 6541 P01.1389.01

C.A 6543 P01.1389.02

 

Complete with carrying bag containing all the accessories:

_ 2 x 1.5 m safety leads (red/blue)

_ 1 x 1.5 m guarded safety lead (black)

_ 3 x crocodile clips (red/blue/black)

_ 1 x test probe (black)

_ 1 x 2-sided condensed user½s manual

_ 1 user½s manual

_ 8 x LR14 batteries (for C.A 6541)

or 1 x 2m mains lead (for C.A 6543)

 

Recommended options

OPTIONAL ACCESSORIES:

Remote control probe P01.1019.35

PC software for C.A 6543 P01.1019.38

Serial printer for C.A 6543 P01.1029.03

Serial-to-parallel adapter

for C.A 6543 P01.1019.41

Pair of 2 test probe leads

(red/ black) P01.1018.55

Set of 3 x 3m safety leads

(red/blue/guarded black) P01.2951.70

 

More products CHAUVIN ARNOUX

EARTH GROUND RESISTANCE TESTER ON PYLONS CHAUVIN ARNOUX CA6474

• Ideal for earth measurements on pylons
• measurement range: 0.001 O to 99.99 kO
• resolution: 0.001 to 10 O
• no-load voltage: 16 or 32 VRMS
• measurement frequency: 41 Hz to 5,018 Hz
• measurement of resistance of earth stakes: 0.01 O to 100kO
• leakproofing: IP53

 

MULTIFUNCTION ELECTRICAL INSTALLATION TESTER CHAUVIN ARNOUX CA6116

• ALL-IN-ONE tool for electrical installation testing
• compliance with the national and international standards (IEC 60364-6, NF C 15-100, VDE 100, XP C 16-600...
• design, ergonomics, simplicity, rapidity and accuracy
• Suitable for all types of neutral systems (TT, TN, IT)
• large backlit graphic screen

 

MEGOHMMETER 15KV CHAUVIN ARNOUX CA6555

• Wide measurement range from 10 kohm to 30 Tohm
• Fixed or programmable test voltage from 40V to 15 kV
• 5mA max. charging current
• Large backlit LCD screen with digital display, bargraph and R(t)+u(t), i(t) and i(u) graphs
• Automatic ratio calculation: DAR / PI / DD / DR (ppm/V)
• Multiple test modes: voltage ramp and step with "burning", "early break" and "I-limit" modes

 

DIGITAL INSULATION MEGOHMMETER 5KV CHAUVIN ARNOUX CA6549

• measurement range: 10k? to 10T?!
• 4 fixed test voltages: 500 / 1,000 / 2,500 and 5,000V
• adjustable test voltage position: 40 to 5,100V in 10V or 100V increments
• step voltage mode: R(Utest) measurement curve viewed on the screen and gradient calculated automatically in ppm/V
• DAR, PI and DD quality ratios calculated automatically
• programmable test length and R(t) measurement curve

 

SOLAR PANEL EFFICIENCY TESTER CHAUVIN ARNOUX FTV100 GREENTEST

• electrical power survey
• Calculation of solar panel efficiency
• Calculation of inverter efficiency
• Voltage up to 1,000 VDC / 600 VAC
• Current up to 1,400 ADC / 3,000 AAC
• AC/DC power: 20,000 WDC / 1,200 WAC

 

THREE-PHASE POWER QUALITY ANALYZER CHAUVIN-ARNOUX CA8435

• C.A 8435, the rugged, waterproof IP67
• Indoor and outdoor use, even when it is raining
• 5 voltage inputs, 4 current inputs
• Continuous recording of all the parameters simultaneously
• Monitoring with alarms
• All types of installations
• Measurement of P, Q, S and D power values (total and per phase)
• Calculation of Pst & Plt flicker values

 

THREE-PHASE ENERGY ANALYZER CHAUVIN-ARNOUX CA8335 QUALISTAR PLUS

• - Voltage ratios: 1 V to 500 kV
• - Mixed sensors: 10 mA to 60 kA depending on sensor
• for quick verification of network quality and simple processing of the results

 

EARTH AND LOOP RESISTANCE TESTER CHAUVIN ARNOUX CA6456

• loop resistance and impedance: L-N, L-L, and L-PE from 0.20 to 4 kO
• short-circuit current displayed up to 40 kA by calculation (Uref/ZL-PE)
• clamp measurement of current and leakage current (option)
• Cat. III, 600V

 

INSULATION MEGOHMETER 5KV CHAUVIN ARNOUX CA6505

• Adjustable test voltage: 40 V to 5,100 V in 10 or 100 V increments
• 500 V: 10 kO to 2 TO
• 1,000 V: 10 kO to 4 TO
• 2,500 V: 10 kO to 10 TO
• 5,000 V: 10 kO to 10 TO

 

INSULATION RESISTANCE MEGOHMMETER 1KV CHAUVIN ARNOUX CA6541

• insulation: up to 4TO (5 cal.) at 50/100/250/500 and 1,000V DC
• automatic calculation of insulation quality ratios: DAR and PI
• programmable test period and plotting of the R(t) curve (automatic memorisation of 20 samples)
• automatic indication of voltage before and after measurement: 1 to 1000V AC/DC
• resistance: from 0.01O to 400kO
• continuity: 0.01O to +40O (audible beep and lead compensation)
• automatic measurement capacity after each insulation measurement: 0.005 to 4.999 ½F