Digital Insulation Megohmmeter 1000V Chauvin Arnoux CA6523

Code: Chauvin Arnoux CA6523


 

Description

Particularly innovative and user-friendly, the C.A 6523 insulation tester is ideal for testing electrical installations and equipment:

 

  • insulation: up to 2G? at 500V and 1,000V DC
  • voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
  • continuity: -20? to +20? (audible beep and compensation of leads)
  • resistance: 0 to 400k?
  • giant 4,000-count display + bargraph (simultaneous reading of the measurement and analogue variance)
  • backlit display
  • programming of alarms
  • remote control probe available as an option
  • back stand for use on a table or on the ground
  • long battery life: 6 x 1.5V batteries
  • measurements in compliance with IEC 61557, NF C 15-100, VDE 0413
  • electrical safety: IEC 1010 600V Cat II
  • dimensions: 211 x 108 x 60mm; weight: 830 g

 

 

 

Standard accessories

C.A 6521...................P01140801D

C.A 6523...................P01140802D

C.A 6525...................P01140803D

 

½ 1 ½hands-free½ carrying case

½ 1 pair of 1.5 m leads, red + black

½ 1 red croc-clip

½ 1 black test probe

½ 6 LR6 batteries

½ 1 set of operating instructions

 

More products CHAUVIN ARNOUX

RCD TESTER CHAUVIN ARNOUX CA6030

• Direct, safe connection to installation mains
• Automatic installation voltage and frequency measurement
• Tests standard, selective, A and AC RCDs
• 5 fixed calibres 10/30/100/300/500mA + 1 calibre adjustable from 6 to 650mA
• Checks RCD trips / trip time measurement (pulse or ramp mode) and exact trip current (ramp mode)

 

EARTH RESISTANCE DIGITAL TESTER CHAUVIN ARNOUX CA6423

• earth resistance: 0.00 to 2,000O (3 cal.)
• 3 fault presence indicators to validate the measurement
• measurement frequency: 128Hz
• connection of rods to colour-coded terminals
• a removable captive connection strip between H and S for measurement of 2-wire resistance
• large 2,000-count digital display with 18mm digits: excellent readability


EARTH GROUND RESISTANCE TESTER CHAUVIN ARNOUX CA6460

• 3-in-1 tester: resistivity, earth, coupling
• measurement range: 0.00 to 2,000? (3 automatic calibres)
• change from 4-wire method to 3-wire method thanks to 1 removable captive bar between E and ES
• 3 fault presence indicators to validate measurement
• measurement frequency: 128Hz

 

EARTH GROUND RESISTANCE TESTER ON PYLONS CHAUVIN ARNOUX CA6472

• 5 tools in 1 with this tester
• extensive measurement ranges: 0.001?to 100 k?
• analysing the frequency behaviour of the earthing systems (from 41 Hz to 5 kHz)
• high-level, expert calculation capabilities
• IP 53 leakproofing

 

ENERGY POWER ANALYZER CHAUVIN-ARNOUX CA8230

• Voltage range: 6VRMS to 600VRMS AC+DC
• AC current range: 5mA to 6,500A
• DC current range: 1A to 1,700A
• Values: Min., Max., Avg., Peak (+/-), CF
• Power: W, VA, var, DF, THD, cos f, tan f
• Energy: Wh, VAh, varh
• Harmonics: up to the 50th order
• IEC1010/EN61010: Cat.III-600V

 

INSULATION RESISTANCE MEGOHMMETER 1KV CHAUVIN ARNOUX CA6541

• insulation: up to 4TO (5 cal.) at 50/100/250/500 and 1,000V DC
• automatic calculation of insulation quality ratios: DAR and PI
• programmable test period and plotting of the R(t) curve (automatic memorisation of 20 samples)
• automatic indication of voltage before and after measurement: 1 to 1000V AC/DC
• resistance: from 0.01O to 400kO
• continuity: 0.01O to +40O (audible beep and lead compensation)
• automatic measurement capacity after each insulation measurement: 0.005 to 4.999 ½F

 

MULTIFUNCTION ELECTRICAL MACHINE TESTER CHAUVIN ARNOUX CA6155

• Measurements in compliance with the IEC 60204 Ed.5 / VDE701/702 / IEC 61439 (IEC 60439) standards
• 200 mA and 10 A continuity measurements
• Insulation resistance at 250 VDC and 500 VDC
• Dielectric test at 1,000 V / 1,890 V / 2,500 V
• Leakage current measurement by substitution method
• Differential leakage current
• Contact leakage current
• Mains power-lead polarity test

 

EARTH GROUNDING RESISTANCE TESTER CHAUVIN ARNOUX CA6462

• 3-in-1 tester: resistivity, earth, coupling
• measurement range: 0.00 to 2,000? (3 automatic calibres)
• change from 4-wire method to 3-wire method thanks to 1 removable captive bar between E and ES
• 3 fault presence indicators to validate measurement
• measurement frequency: 128Hz

 

DIGITAL INSULATION MEGOHMMETER 500V CHAUVIN ARNOUX CA6521

• insulation: up to 2G? at 250V and 500V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep)
• giant 400-count display + bargraph (simultaneous reading of measurement and analogue variance)
• back stand for use on a table or on the ground
• long battery life: 6 x 1.5V batteries


EARTH RESISTANCE TESTER CHAUVIN ARNOUX CA6421

• earth resistance: 0.5Oat 1,000 O (log scale) )
• 3 fault presence indicators to validate the measurement
• measurement frequency: 128Hz
• connection of rods to colour-coded terminals
• removable captive connection strip between S and H for 2-wire resistance measurements