Insulation Megohmmeter 5000V Chauvin Arnoux CA6545

Code: Chauvin Arnoux CA6545


 

Datasheet PDF, 0.72 Mb

Description

In its site-proof case, the C.A 6545 megohmmeter can be used for quantitative and qualitative analysis of insulation. It also automatically measures voltage, capacitance and residual current.

 

  • wide range from 30k? to 10T? !
  • 4 fixed test voltages: 500/1,000/2,500 and 5,000V
  • programmable test voltage position: from 40 to 5,100V in increments of 10V or 100V
  • giant backlit LCD screen with digital display + bargraph
  • qualitative analysis: automatic calculation of DAR, PI and DD (dielectric discharge) ratios and tracing of the R(t) curve
  • numerous functions: programmed test duration, lock-in of test voltage, smooth function, programmable alarms, etc.
  • power supply: rechargeable NiMH battery with a 30-day service life for 10 DAR measurements and 5 PI measurements per day
  • electrical safety: IEC 61010-1 Cat.III 1,000V or Cat.I 2,500V and 61557
  • dimensions: 270x250x180mm; weight: 4.3kg

 

 

Standard accessories

C.A 6545 Megohmmeter .................................... P01139701

Delivered with a carrying bag containing:

½ 2 safety leads 3 m long with HV plug and HV crocodile clip (red/blue)

½ 1 guarded safety plug 3 m long with an HV plug with rear connection

and an HV crocodile clip (black)

½ 1 lead with rear connection (blue) 0.35 m long

½ 1 mains power cable 2 m long

½ 1 simplified operating manual

½ 1 operating manual in 5 languages

 

Recommended options

 

 

More products CHAUVIN ARNOUX

INSULATION MEGOHMETER 1KV CHAUVIN ARNOUX CA6543

• insulation: up to 4TO (5 cal.) at 50/100/250/500 and 1,000V DC
• automatic calculation of insulation quality ratios: DAR and PI
• programmable test period and plottingof the R(t) curve
• automatic indication of voltage before and after measurement: 1 to 1,000V AC/DC
• resistance: 0.01O to 400kO
• continuity: 0.01O to +40O (audible beep and lead compensation )

 

RCD TESTER CHAUVIN ARNOUX CA6030

• Direct, safe connection to installation mains
• Automatic installation voltage and frequency measurement
• Tests standard, selective, A and AC RCDs
• 5 fixed calibres 10/30/100/300/500mA + 1 calibre adjustable from 6 to 650mA
• Checks RCD trips / trip time measurement (pulse or ramp mode) and exact trip current (ramp mode)

 

EARTH GROUND RESISTANCE TESTER ON PYLONS CHAUVIN ARNOUX CA6474

• Ideal for earth measurements on pylons
• measurement range: 0.001 O to 99.99 kO
• resolution: 0.001 to 10 O
• no-load voltage: 16 or 32 VRMS
• measurement frequency: 41 Hz to 5,018 Hz
• measurement of resistance of earth stakes: 0.01 O to 100kO
• leakproofing: IP53

 

INSULATION MEGOHMMETER 5000V CHAUVIN ARNOUX CA6545

• wide range from 30k? to 10T? !
• 4 fixed test voltages: 500/1,000/2,500 and 5,000V
• programmable test voltage position: from 40 to 5,100V in increments of 10V or 100V
• giant backlit LCD screen with digital display + bargraph
• qualitative analysis: automatic calculation of DAR, PI and DD

 

THREE-PHASE POWER QUALITY ANALYZER CHAUVIN-ARNOUX CA8435

• C.A 8435, the rugged, waterproof IP67
• Indoor and outdoor use, even when it is raining
• 5 voltage inputs, 4 current inputs
• Continuous recording of all the parameters simultaneously
• Monitoring with alarms
• All types of installations
• Measurement of P, Q, S and D power values (total and per phase)
• Calculation of Pst & Plt flicker values

 

EARTHING RESISTANCE TESTER CHAUVIN ARNOUX CA6470N TERCA3

• extensive measurement ranges: 0.001? to 100 k?
• adjustment of the measurement frequency between 41 Hz and 512 Hz
• 10 times greater accuracy due to its 4-pole measurement method
• measuring soil resistivity
• calculate r automatically by the Wenner or Schlumberger methods

 

MEGOHMMETER 10KV CHAUVIN ARNOUX CA6550

• Wide measurement range from 10 kohm to 25 Tohm
• Fixed or programmable test voltage from 40V to 10 kV
• 5mA max charging current
• Large backlit LCD screen with digital display, bargraph and R(t)+u(t), i(t) and i(u) graphs
• Automatic ratio calculation: DAR / PI / DD / DR (ppm/V)

 

EARTH GROUNDING RESISTANCE TESTER CHAUVIN ARNOUX CA6462

• 3-in-1 tester: resistivity, earth, coupling
• measurement range: 0.00 to 2,000? (3 automatic calibres)
• change from 4-wire method to 3-wire method thanks to 1 removable captive bar between E and ES
• 3 fault presence indicators to validate measurement
• measurement frequency: 128Hz

 

MULTIFUNCTION ELECTRICAL MACHINE TESTER CHAUVIN ARNOUX CA6155

• Measurements in compliance with the IEC 60204 Ed.5 / VDE701/702 / IEC 61439 (IEC 60439) standards
• 200 mA and 10 A continuity measurements
• Insulation resistance at 250 VDC and 500 VDC
• Dielectric test at 1,000 V / 1,890 V / 2,500 V
• Leakage current measurement by substitution method
• Differential leakage current
• Contact leakage current
• Mains power-lead polarity test

 

SOLAR PHOTOVOLTAIC PANELS TESTER CHAUVIN ARNOUX FTV200

• I-V curve with cursor
• Voltage measurement up to 1,000 VDC
• Current measurement up to 10 ADC
• Pyranometer up to 2,000 W/m2
• Mesure of r½sistance Rs
• 80 MB internal storage capacity
• More than 10,000 different panel references
• Possibility of external USB key for storage