RCD Tester Chauvin Arnoux CA6030

Code: Chauvin Arnoux CA6030


 

Datasheet PDF, 1.11 Mb

Description

Innovative and particularly user-friendly, the C.A 6030 RCD is particularly easy to use and offers high metrological performance for the testing protection systems and installations' compliance with the European and international standards NF C 15-100, VDE 0100, NIN/NIV, IEEE 16th, ½VE EN-1.

 

  • Direct, safe connection to installation mains
  • Reliable measurements due to automatic permutation of L and N inputs if conductors are reversed at socket connection
  • Automatic installation voltage and frequency measurement
  • Tests standard, selective, A and AC RCDs
  • 5 fixed calibres 10/30/100/300/500mA + 1 calibre adjustable from 6 to 650mA
  • Checks RCD trips / trip time measurement (pulse or ramp mode) and exact trip current (ramp mode)
  • Power-on earth measurement: earth loop and 1P earth
  • Current and leakage current measurement clamp (option)
  • Phase rotation test (2 or 3-wire)
  • Programmable alarms, date-stamped recording of measurement readings, data printout using standard printer, direct transfer of data to PC (transfer application included as standard)
  • Large backlit display / "hands-free" pouch
  • Battery operated - battery life: 2,000 tests
  • Dimensions: 270x250x180mm ; weight : 900g

 

 

 

 

Standard accessories

C.A 6030 RCD Tester (Euro) P01.1915.11

Supplied with "hands free" carrying strap and accessories bag:

1 mains lead

1 3-wire lead

3 test probes / 3 crocodile clips

1 user's manual in 5 languages

1 data transfer application software

1 communication lead

 

Recommended options

 

 

More products CHAUVIN ARNOUX

THREE-PHASE POWER QUALITY ANALYZER CHAUVIN-ARNOUX CA8435

• C.A 8435, the rugged, waterproof IP67
• Indoor and outdoor use, even when it is raining
• 5 voltage inputs, 4 current inputs
• Continuous recording of all the parameters simultaneously
• Monitoring with alarms
• All types of installations
• Measurement of P, Q, S and D power values (total and per phase)
• Calculation of Pst & Plt flicker values

 

EARTH RESISTANCE DIGITAL TESTER CHAUVIN ARNOUX CA6423

• earth resistance: 0.00 to 2,000O (3 cal.)
• 3 fault presence indicators to validate the measurement
• measurement frequency: 128Hz
• connection of rods to colour-coded terminals
• a removable captive connection strip between H and S for measurement of 2-wire resistance
• large 2,000-count digital display with 18mm digits: excellent readability


MEGOHMMETER 10KV CHAUVIN ARNOUX CA6550

• Wide measurement range from 10 kohm to 25 Tohm
• Fixed or programmable test voltage from 40V to 10 kV
• 5mA max charging current
• Large backlit LCD screen with digital display, bargraph and R(t)+u(t), i(t) and i(u) graphs
• Automatic ratio calculation: DAR / PI / DD / DR (ppm/V)

 

MEGOHMMETER 15KV CHAUVIN ARNOUX CA6555

• Wide measurement range from 10 kohm to 30 Tohm
• Fixed or programmable test voltage from 40V to 15 kV
• 5mA max. charging current
• Large backlit LCD screen with digital display, bargraph and R(t)+u(t), i(t) and i(u) graphs
• Automatic ratio calculation: DAR / PI / DD / DR (ppm/V)
• Multiple test modes: voltage ramp and step with "burning", "early break" and "I-limit" modes

 

DIGITAL INSULATION MEGOHMMETER 1KV CHAUVIN ARNOUX CA6525

• insulation: up to 2G? at 250V, 500V and 1,000V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep and compensation of leads)
• resistance: 0 to 400k?
• giant 4,000-count display + bargraph


EARTHING RESISTANCE TESTER CHAUVIN ARNOUX CA6471

• extensive measurement ranges: 0.001? to 100 k?
• adjustment of the measurement frequency between 41 Hz and 512 Hz
• 10 times greater accuracy due to its 4-pole measurement method
• measuring soil resistivity
• calculate r automatically by the Wenner or Schlumberger methods
• Ergonomic, comprehensive and accurate

 

INSULATION MEGOHMMETER 500V CHAUVIN ARNOUX CA6511

• insulation: up to 1,000MO (1 cal.) at 500V DC
• AC voltage: 0 to 600V
• continuity: -10? to +10? (I=200mA)
• automatic testing of absence of voltage by direct measurement
• single input on two colour-coded terminals


RCD TESTER CHAUVIN ARNOUX CA6030

• Direct, safe connection to installation mains
• Automatic installation voltage and frequency measurement
• Tests standard, selective, A and AC RCDs
• 5 fixed calibres 10/30/100/300/500mA + 1 calibre adjustable from 6 to 650mA
• Checks RCD trips / trip time measurement (pulse or ramp mode) and exact trip current (ramp mode)

 

ELECTRICAL MACHINE CERTIFICATION TESTER CHAUVIN ARNOUX CA6160

• dielectric test: standard measurement modes (Un from 100 to 5,000V with Ilim 500mA) and programmed modes (t1, t2, t3, U1, U2)
• continuity: up to 100O with 0.1 < ITEST < 25A
• voltage drop: up to 100V (Itest > 10A)
• insulation resistance: up to 1GO at 250/500VDC and 1,000VDC
• measurement of internal and external discharge time (at the plug)
• leakage current: operating and residual up to 20mA, contact up to 2mA
• functional testing: voltage, current, frequency and power

 

THREE-PHASE ENERGY QUALITY ANALYZER CHAUVIN-ARNOUX CA8334B QUALISTAR

• Complete three-phase analysis:
• - voltage, current,
• - power / energy,
• - harmonics (up to 50th order), flicker,
• - measurement of transients,
• - alarm trigger...
• Processing of data via PC software QualistarView or DataViewer Pro.
• Recording of 12 screens
• Compliant with IEC 61010-1, 600V Cat.IV