Digital Insulation Megohmmeter 1kV Chauvin Arnoux CA6525

Code: Chauvin Arnoux CA6525


 

Description

Particularly innovative and user-friendly, the C.A 6525 insulation tester is ideal for testing electrical installations and equipment:

 

  • insulation: up to 2G? at 250V, 500V and 1,000V DC
  • voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
  • continuity: -20? to +20? (audible beep and compensation of leads)
  • resistance: 0 to 400k?
  • giant 4,000-count display + bargraph (simultaneous reading of the measurement and analogue variance)
  • backlit rear display
  • programming of alarms
  • timer function (0 to 15min)
  • remote control probe available as an option
  • back stand for use on a table or on the ground
  • long battery life: 6 x 1.5V batteries
  • Measurements in compliance with IEC 61557, NF C 15-100, VDE 0413
  • electrical safety: IEC 1010 600V Cat. II
  • dimensions: 211 x 108 x 60mm; weight: 830g

 

 

Standard accessories

C.A 6521...................P01140801D

C.A 6523...................P01140802D

C.A 6525...................P01140803D

 

½ 1 ½hands-free½ carrying case

½ 1 pair of 1.5 m leads, red + black

½ 1 red croc-clip

½ 1 black test probe

½ 6 LR6 batteries

½ 1 set of operating instructions

 

More products CHAUVIN ARNOUX

EARTH GROUND RESISTANCE TESTER ON PYLONS CHAUVIN ARNOUX CA6474

• Ideal for earth measurements on pylons
• measurement range: 0.001 O to 99.99 kO
• resolution: 0.001 to 10 O
• no-load voltage: 16 or 32 VRMS
• measurement frequency: 41 Hz to 5,018 Hz
• measurement of resistance of earth stakes: 0.01 O to 100kO
• leakproofing: IP53

 

TRANFORMER RATIO TESTER CHAUVIN ARNOUX DTR8510

• calculate the ratios
• NiMH battery life of up to 10 hours
• Automatic calibration and balancing
• Low-voltage test
• Digital display ½ display of ratios, winding direction - % deviation
• Degauss function

 

INSULATION MEGOHMETER 1KV CHAUVIN ARNOUX CA6543

• insulation: up to 4TO (5 cal.) at 50/100/250/500 and 1,000V DC
• automatic calculation of insulation quality ratios: DAR and PI
• programmable test period and plottingof the R(t) curve
• automatic indication of voltage before and after measurement: 1 to 1,000V AC/DC
• resistance: 0.01O to 400kO
• continuity: 0.01O to +40O (audible beep and lead compensation )

 

DIGITAL INSULATION MEGOHMMETER 1000V CHAUVIN ARNOUX CA6523

• insulation: up to 2G? at 500V and 1,000V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep and compensation of leads)
• resistance: 0 to 400k?
• giant 4,000-count display + bargraph


INSULATION MEGOHMETER 5KV CHAUVIN ARNOUX CA6505

• Adjustable test voltage: 40 V to 5,100 V in 10 or 100 V increments
• 500 V: 10 kO to 2 TO
• 1,000 V: 10 kO to 4 TO
• 2,500 V: 10 kO to 10 TO
• 5,000 V: 10 kO to 10 TO

 

ANALOGUE MEGOHMMETER 1000V CHAUVIN ARNOUX CA6513

• insulation: up to 1,000MO (1 cal.) at 500V and 1,000V DC
• AC voltage: 0 to 600V
• resistance: 0 to 1,000O
• continuity: -10O to +10O (I=200mA)
• automatic testing of voltage absence by direct measurement


MULTIFUNCTION ELECTRICAL MACHINE TESTER CHAUVIN ARNOUX CA6155

• Measurements in compliance with the IEC 60204 Ed.5 / VDE701/702 / IEC 61439 (IEC 60439) standards
• 200 mA and 10 A continuity measurements
• Insulation resistance at 250 VDC and 500 VDC
• Dielectric test at 1,000 V / 1,890 V / 2,500 V
• Leakage current measurement by substitution method
• Differential leakage current
• Contact leakage current
• Mains power-lead polarity test

 

ELECTRICAL INSTALLATION TESTER CHAUVIN ARNOUX CA6114

• automatic installation status test immediately after connection
• measurement of voltage (10 to 440V AC/DC) and frequency (15.3 to 450Hz)
• installation insulation measurement at 500V
• standard earth connection resistance measurement (1 stake + loop method)
• PE conductor continuity test
• measurement of internal loops
• testing of RCDs up to 500mA (exact tripping time and current)
• phase rotation testing

 

EARTHING RESISTANCE TESTER CHAUVIN ARNOUX CA6471

• extensive measurement ranges: 0.001? to 100 k?
• adjustment of the measurement frequency between 41 Hz and 512 Hz
• 10 times greater accuracy due to its 4-pole measurement method
• measuring soil resistivity
• calculate r automatically by the Wenner or Schlumberger methods
• Ergonomic, comprehensive and accurate

 

DIGITAL INSULATION MEGOHMMETER 500V CHAUVIN ARNOUX CA6521

• insulation: up to 2G? at 250V and 500V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep)
• giant 400-count display + bargraph (simultaneous reading of measurement and analogue variance)
• back stand for use on a table or on the ground
• long battery life: 6 x 1.5V batteries