Digital Insulation Megohmmeter 1kV Chauvin Arnoux CA6525

Code: Chauvin Arnoux CA6525


 

Description

Particularly innovative and user-friendly, the C.A 6525 insulation tester is ideal for testing electrical installations and equipment:

 

  • insulation: up to 2G? at 250V, 500V and 1,000V DC
  • voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
  • continuity: -20? to +20? (audible beep and compensation of leads)
  • resistance: 0 to 400k?
  • giant 4,000-count display + bargraph (simultaneous reading of the measurement and analogue variance)
  • backlit rear display
  • programming of alarms
  • timer function (0 to 15min)
  • remote control probe available as an option
  • back stand for use on a table or on the ground
  • long battery life: 6 x 1.5V batteries
  • Measurements in compliance with IEC 61557, NF C 15-100, VDE 0413
  • electrical safety: IEC 1010 600V Cat. II
  • dimensions: 211 x 108 x 60mm; weight: 830g

 

 

Standard accessories

C.A 6521...................P01140801D

C.A 6523...................P01140802D

C.A 6525...................P01140803D

 

½ 1 ½hands-free½ carrying case

½ 1 pair of 1.5 m leads, red + black

½ 1 red croc-clip

½ 1 black test probe

½ 6 LR6 batteries

½ 1 set of operating instructions

 

More products CHAUVIN ARNOUX

DIGITAL INSULATION MEGOHMMETER 5KV CHAUVIN ARNOUX CA6549

• measurement range: 10k? to 10T?!
• 4 fixed test voltages: 500 / 1,000 / 2,500 and 5,000V
• adjustable test voltage position: 40 to 5,100V in 10V or 100V increments
• step voltage mode: R(Utest) measurement curve viewed on the screen and gradient calculated automatically in ppm/V
• DAR, PI and DD quality ratios calculated automatically
• programmable test length and R(t) measurement curve

 

THREE-PHASE POWER QUALITY ANALYZER CHAUVIN-ARNOUX CA8332B QUALISTAR

• Complete three-phase analysis:
• - voltage, current,
• - power / energy,
• - harmonics (50th rank), flicker,
• - alarm trigger...
• Processing of data with DataView PC software.
• Working memory: 2MB

 

RCD TESTER CHAUVIN ARNOUX CA6030

• Direct, safe connection to installation mains
• Automatic installation voltage and frequency measurement
• Tests standard, selective, A and AC RCDs
• 5 fixed calibres 10/30/100/300/500mA + 1 calibre adjustable from 6 to 650mA
• Checks RCD trips / trip time measurement (pulse or ramp mode) and exact trip current (ramp mode)

 

SOLAR PHOTOVOLTAIC PANELS TESTER CHAUVIN ARNOUX FTV200

• I-V curve with cursor
• Voltage measurement up to 1,000 VDC
• Current measurement up to 10 ADC
• Pyranometer up to 2,000 W/m2
• Mesure of r½sistance Rs
• 80 MB internal storage capacity
• More than 10,000 different panel references
• Possibility of external USB key for storage

 

EARTH AND LOOP RESISTANCE TESTER CHAUVIN ARNOUX CA6456

• loop resistance and impedance: L-N, L-L, and L-PE from 0.20 to 4 kO
• short-circuit current displayed up to 40 kA by calculation (Uref/ZL-PE)
• clamp measurement of current and leakage current (option)
• Cat. III, 600V

 

INSULATION MEGOHMETER 1KV CHAUVIN ARNOUX CA6543

• insulation: up to 4TO (5 cal.) at 50/100/250/500 and 1,000V DC
• automatic calculation of insulation quality ratios: DAR and PI
• programmable test period and plottingof the R(t) curve
• automatic indication of voltage before and after measurement: 1 to 1,000V AC/DC
• resistance: 0.01O to 400kO
• continuity: 0.01O to +40O (audible beep and lead compensation )

 

EARTHING RESISTANCE TESTER CHAUVIN ARNOUX CA6470N TERCA3

• extensive measurement ranges: 0.001? to 100 k?
• adjustment of the measurement frequency between 41 Hz and 512 Hz
• 10 times greater accuracy due to its 4-pole measurement method
• measuring soil resistivity
• calculate r automatically by the Wenner or Schlumberger methods

 

ENERGY POWER ANALYZER AND MOTOR DIAGNOSTIC TESTER CHAUVIN-ARNOUX CA8220

• Voltage and current with instant display
• TRMS AC+DC value
• peak values and THD
• Short-term flicker measurement
• offers instant display of the waveform
• comprehensive power and energy analysis on both single-phase and three-phase systems
• Up to several days½ recording
• Customization of alarm settings

 

MULTIFUNCTION ELECTRICAL MACHINE TESTER CHAUVIN ARNOUX CA6155

• Measurements in compliance with the IEC 60204 Ed.5 / VDE701/702 / IEC 61439 (IEC 60439) standards
• 200 mA and 10 A continuity measurements
• Insulation resistance at 250 VDC and 500 VDC
• Dielectric test at 1,000 V / 1,890 V / 2,500 V
• Leakage current measurement by substitution method
• Differential leakage current
• Contact leakage current
• Mains power-lead polarity test

 

THREE-PHASE ENERGY QUALITY ANALYZER CHAUVIN-ARNOUX CA8334B QUALISTAR

• Complete three-phase analysis:
• - voltage, current,
• - power / energy,
• - harmonics (up to 50th order), flicker,
• - measurement of transients,
• - alarm trigger...
• Processing of data via PC software QualistarView or DataViewer Pro.
• Recording of 12 screens
• Compliant with IEC 61010-1, 600V Cat.IV