Osciloscop USB 2 x 200 MHz Agilent U2702A

Cod: Agilent U2702A


 

Brosura produs , 0.33 Mb

Descriere

  • 200 MHz bandwidth
  • 2 channels
  • 32 Mpts memory depth, 64 Mpts interleaved single-shot
  • 1 GSa/s sample rate on 2 channels interleaved, 500 MSa/s each channel
  • Hi-Speed USB 2.0, USBTMC-USB488 standard (Compatible with Microsoft Windows operating systems only)
  • Waveform Zoom and Maths Function
  • 26 pre-build automatic measurement
  • FFT including max peak search
  • Advance Triggering including edge, pulse width and line selectable video
 

Alte produse Rohde & Schwarz

MODUL ACHIZITIE USB 4-CANALE 500KSA/S SIMULTAN AGILENT U2542A

• High speed USB 2.0 (480MBit/s)
• 16-bit resolution
• simultaneous analog input channels
• up to 500 kSa/s/ch
• 2 12-bit analog output channels
• 1 MSa/s analog output update rate
• 24-bit programmable TTL input/output channels

 

GENERATOR DE FUNCTII / FORME DE UNDA ARBITRARE 2 X 30 MHZ AGILENT 33522A

• 2 x 30 MHz sine, square, and pulse bandwidth cover more applications
• 250 MSa/s, 16-bit sampling rate for higher time-resolution arbitrary waveforms
• Dual-channel model with independent or coupled channels

 

MODUL MULTIPLEXOR 16 CANALE AGILENT 34902A

• 16 Channel Multiplexer
• Two- and four-wire scanning
• 250 ch/s scanning
• Built-in thermocouple reference junction

 

GENERATOR IMPULSURI SI DATE 660 MHZ AGILENT 81130A 81132A

• 1 kHz to 660 MHz
• 1 or 2 Channels(order 2 x 81132A modules)
• 500 ps typ.fixed
• Up to 2.5 Vpp into 50 O

 

OSCILOSCOP DIGITAL 4 X 70 MHZ AGILENT DSOX2004A

• 70 MHz bandwidth
• 4 analog channels
• 1GSa/s per channel sample rate

 

MODUL MATRICE DUAL/QUAD 4 X 8 AGILENT 34933A

• Dual 4x8, 8x8, or 4x16 2-wire configurations
• 64 2-wire or 128 1-wire cross-points
• High-speed reed relays

 

MULTIMETRU DIGITAL PORTABIL CU DATA LOGGING 4 DIGIT AGILENT U1242A U1242B

• 4 digit
• 10,000 count dual display
• 0.09% basic DCV accuracy
• True RMS AC
• J & K-Type temperature measurements
• Data logging
• Advanced functions: capacitance, switch counter, harmonic ratio, dual/differential temperature

 

MODUL PXI SWITCH MATRICE 8 X 32 100V/2A AGILENT M9122A

• Connect multiple instruments to multiple points for automated test applications
• 8x32 high-density 1-wire switch matrix
• 100Vrms
• 2A switch/carry current
• 60W max power
• Durable 60W armature switches

 

ANALIZOR LOGIC PORTABIL 136 CANALE AGILENT 16804A

• 136-channel portable logic analyzer
• 4 GHz (250 ps) timing zoom with 64 K memory
• 1.0 GHz / 500 MHz (half / full-channel) conventional timing with deep memory
• up to 450 MHz State clock rates
• up to 500 Mb/s Data rates
• up to 32 M acquisition memory depth

 

OSCILOSCOP DIGITAL 2 X 100 MHZ CU ANALIZOR LOGIC 16 CANALE AGILENT MSOX3012A

• 100 MHz bandwidth
• 2 analog channels plus 16 digital channels
• 2 GSa/s per channel sample rate, 4 GSa/s half-channel interleaved mode