Digital Oscilloscope 2 x 350 MHz & Logic Analyzer 16 channels Agilent MSOX3032A

Code: Agilent Infiniivision MSOX3032A


 

Datasheet , 0.33 Mb

Description

  • 350 MHz bandwidth
  • 2 analog channels plus 16 digital channels
  • 2 GSa/s per channel sample rate, 4 GSa/s half-channel interleaved mode
  • Largest screen in its class: 8.5-inch WVGA display
  • Fastest update rate of 1,000,000 waveforms per second
  • Deepest memory: 4 Mpts
  • Best-in-class oscilloscope
  • Integrated logic timing analyzer (MSO)
  • Only built-in 20-MHz function generator: WaveGen
  • Only hardware-based protocol analyzer
  • Upgradability: add bandwidth, digital channels, or WaveGen after purchase
  • Optional serial protocol analysis applications including: I²C, SPI, RS232, UART, CAN, LIN, and I²S
  • Segmented memory
  • Mask Testing
 

Standard accessories

  • 2 x N2890B Passive probe 500 MHz 10:1 attenuation
  • N6450-60001 16 digital channel MSO probe
  • Calibration Certificate
  • Power Cord
  • Software
  • Manual
 

Recommended options

Options

 

DSOX3BW52

Bandwidth upgrade from 350 MHz to 500 MHz

DSOX3WAVEGEN

WaveGen (built-in function generator)

DSOX3MEMUP

Memory Upgrade: 4 Mpts half-channel

DSOXEDK

Educator"™s kit

DSOX3MASK

Mask testing

DSOX3SGM

Segmented memory

DSOX3EMBD

Embedded serial triggering and analysis (I2C, SPI)

DSOX3COMP

Computer serial triggering and analysis (RS232/422/485/UART)

DSOX3AUTO

Automotive serial triggering and analysis (CAN, LIN)

DSOX3AUDIO

Audio serial triggering and analysis (I2S)

U1881A

Power measurement and analysis

B4610A

PC offline viewing

 

Recommended Probes

 

N2889A

350 MHz passive probe 10:1/1:1 switchable attenuation

10076A

250 MHz 100:1, 4 kV high-voltage passive probe

N2771B

passive probe 50 MHz 1000:1 attenuation

N2795A

single-ended active probe 1 GHz ±8 V with AutoProbe interface

N2790A

differential active probe 100 MHz ±1.4 kV with AutoProbe interface

N2792A

differential active probe 200 MHz ±20V

N2793A

differential active probe 800 MHz ±15V

1146A

100 kHz, 100 A, AC/DC current probe

1147A

AC/DC current probe 50 MHz 15 A with AutoProbe interface

N2893A

AC/DC current probe 100 MHz 15 A with AutoProbe interface

 

Recommended Accessories

 

DSOXLAN

LAN/VGA connection module

DSOXGPIB

GPIB connection module

N6456A

Rack mount kit

N6457A

Soft carrying case and front panel cover

N6458A

Hard copy manual

 

More products Agilent 3000X 100-500MHz

DIGITAL OSCILLOSCOPE 4 X 100 MHZ & LOGIC ANALYZER 16 CHANNELS AGILENT MSOX3014A

• 100 MHz bandwidth
• 4 analog channels plus 16 digital channels
• 2 GSa/s per channel sample rate, 4 GSa/s half-channel interleaved mode


PXI SWITCH SPDT MODULE 60-CHANNELS 100VRMS/1A AGILENT M9131A

• General purpose switching to control external devices or
• switching in light loads or power supplies
• 64-channel SPDT switch
• 100Vrms
• 1A switch/carry current
• 20W max power

 

AGILENT 81110A 81111A PULSE GENERATOR 165 MHZ

• 1 mHz to 165 MHz
• 1 or 2 Channels(order 2 x 81111A modules)
• 2 ns to 200 ms variable transition time
• Up to 10 Vpp into 50 O (20 Vpp into open circuit)

 

4 X 16 DUAL MATRIX MODULE AGILENT 34932A

• Dual 4x16, 8x16, or 4x32 configurations
• 128 2-wire cross-points
• 300V, 1A switch
• 2A carry current

 

AGILENT U3606A DIGITAL PRECISION MULTIMETER 5.5 DIGIT & POWER SUPPLY

• 5.5 digit
• 0.025% DC Voltage accuracy
• 120,000 counts resolution
• Single-output dual range of 30V/1A or 8V/3A

 

AGILENT N5182A MXG VECTOR SIGNAL GENERATOR 100 KHZ..3 GHZ/ 6 GHZ

• 100 kHz to 3 GHz or 6 GHz
• 0.01 Hz resolution
• >+23 dBm up to 3 GHz using a highly-reliable, fast-switching electronic attenuator
• 100 MHz internal I/Q baseband generator
• Up to 64 MSa playback memory and 800 MSa storage

 

AGILENT 81160A PULSE FUNCTION ARBITRARY NOISE GENERATOR 500 MHZ

• 1 µHz - 330 MHz pulse generation with variable rise/fall time
• 1 µHz - 500 MHz sine waveform output
• 14-bit, 2.5 GSa/s arbitrary waveforms
• 1 or 2 channel, coupled and uncoupled

 

USB MODULAR DATA ACQUISITION UNIT 4-CHANNELS 2MSA/S SIMULTANEOUS AGILENT U2531A

• High speed USB 2.0 (480MBit/s)
• 14-bit resolution
• simultaneous analog input channels
• up to 2 MSa/s/ch
• 2 12-bit analog output channels
• 1 MSa/s analog output update rate
• 24-bit programmable TTL input/output channels

 

PXI RF MATRIX SWITCH 3GHZ 1 X 8, 50 OHM AGILENT M9148A

• RF switching to 3 GHz
• 30V, 1A, 10W switching
• 42 dB isolation at 1 GHz
• 1.2 dB insertion loss at 3 GHz

 

AGILENT 81110A 81112A PULSE GENERATOR 330 MHZ

• 1 mHz to 330 MHz
• 1 or 2 Channels(order 2 x 81112A modules)
• 800 ps or 1.6 ns selectable
• Up to 3.8 Vpp into 50 O