BAUR shirla Cable sheath testing and fault location system

Cod: BAUR shirla


 

Brosura produs PDF, 0.21 Mb
     

Descriere

Shirla the fault location system is used for cable and cable sheath testing as well as for pre-location and pinpointing of cable faults. The pre-location based on the measuring bridge principle according to Murray and Glaser that is designed especially for power cables, also enables pre-location for control and lighting cables. Null balance and evaluation take place automatically.

 

Features:

  • Cable and cable sheath testing up to 10 kVC
  • Resistance measurement
  • Cable and cable sheath fault pre-location with precision measuring bridge
  • Adjustable cable sections that can be defined with length, conductor cross-section and material respectively and can be considered in the distance calculation
 

Alte produse BAUR

BAUR PGK 110 HB HIGH-VOLTAGE TEST DEVICE

• Testing of medium- and high-voltage cables
• DC voltage testing of up to 110 kV output voltage with positive or negative polarity
• AC voltage testing - up to 80 kV for switchgear, busbars and insulating elements
• Easy-to-maintain 2-piece design

 

BAUR DTA IL OIL BREAKDOWN VOLTAGE TESTER

• Inline insulating oil testing in oil preparation systems
• Quality assurance during production processes
• Improved, easy oil sample handling
• Integration in existing production process control possible

 

BAUR SHIRLA CABLE SHEATH TESTING AND FAULT LOCATION SYSTEM

• Cable and cable sheath testing up to 10 kVC
• Resistance measurement
• Cable and cable sheath fault pre-location with precision measuring bridge
• Adjustable cable sections that can be defined with length, conductor cross-section and material respectively and can be considered in the distance calculation

 

BAUR PGK 70/2.5 HB HIGH-VOLTAGE TEST DEVICE

• Operation as DC or Ac testing device
• Polarity of the DC voltage can be easily be reserved
• Robust and durable

 

BAUR ATG 2 BURN DOWN TRANSFORMER

• Portable device for changing the fault resistance
• Useful for cables that are difficult to access
• Proven methods for complicated faults
• Independent current and voltage control on each burning level

 

BAUR PAULA PHASE DETECTOR

• Clear phase determination possible in cable lengths up to 40 km
• Highest level of safety when used on earthed and shorted cables in compliance with EN 50110-1 (DIN VDE 0105-100)
• Suitable for all switchgear constructions due to compact design of the signal injectors
• Ready for operation for up to 2 weeks (standby mode)

 

BAUR SSG SERIES SURGE VOLTAGE GENERATOR

• High surge voltage up to 32 kV
• Continuously adjustable voltage
• Voltage monitoring through kV meters with 3 measuring ranges
• Automatic discharge unit

 

BAUR PHG 70 / PHG 80 PORTABLE VLF TEST SYSTEM

• 3 voltage shapes in one device: VLF truesinus®, VLF square wave and DC voltage
• For medium-voltage cables of up to 50 kV operating voltage
• Cable testing, fault conditioning, cable sheath testing

 

BAUR KMF 1 SEARCH RECEIVER

• Battery mode
• Zero point compensation
• Accurate location of cable sheath faults
• Battery test

 

BAUR VIOLA AND VIOLA TD HIGH-VOLTAGE TEST AND DIAGNOSTICS DEVICE

• High performance and compact
• Precise and non-destructive determination of the cable condition
• Easy and quick test setup
• Automatic testing and diagnostic sequences