BAUR SSG Series Surge voltage generator

Cod: BAUR SSG 1100/1500/2100/3000


 

Brosura produs PDF, 0.66 Mb

Descriere

Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.

 

Features:

  • High surge voltage up to 32 kV
  • Continuously adjustable voltage
  • Voltage monitoring through kV meters with 3 measuring ranges
  • Automatic discharge unit
 

Alte produse BAUR

BAUR PHG 70 / PHG 80 PORTABLE VLF TEST SYSTEM

• 3 voltage shapes in one device: VLF truesinus®, VLF square wave and DC voltage
• For medium-voltage cables of up to 50 kV operating voltage
• Cable testing, fault conditioning, cable sheath testing

 

BAUR PGK 70 HB HIGH-VOLTAGE TEST DEVICE

• Testing of medium- and high-voltage cables
• DC voltage testing of up to 70 kV output voltage with positive or negative polarity
• AC voltage testing - up to 55 kV for switchgear, busbars and insulating elements
• Easy-to-maintain 2-piece design

 

BAUR SHIRLA CABLE SHEATH TESTING AND FAULT LOCATION SYSTEM

• Cable and cable sheath testing up to 10 kVC
• Resistance measurement
• Cable and cable sheath fault pre-location with precision measuring bridge
• Adjustable cable sections that can be defined with length, conductor cross-section and material respectively and can be considered in the distance calculation

 

BAUR KSG 200 / KSG 200 T

• Cable identification on all types of de-energised cables
• Reliable verification of the cable identification by means
• of the highly precise three-factor-analysis ATP
• Safe cable identification on live low-voltage cables
• Connection technology according to CAT IV/600 V

 

BAUR DTL C OIL BREAKDOWN VOLTAGE TESTER

• Fully automatic dissipation factor measurement
• Pre-programmed standards
• Maximum accuracy

 

BAUR PHG 70 TD PD / PHG 80 TD PD VLF TEST AND DIAGNOSTICS SYSTEM

• Compact, enclosed design in 19½ format
• Variable installation option with separate control and voltage unit
• Variable connection options to cable stations of different models

 

BAUR KMF 1 SEARCH RECEIVER

• Battery mode
• Zero point compensation
• Accurate location of cable sheath faults
• Battery test

 

BAUR IRG 2000 TIME DOMAIN REFLECTOMETER

• Easy and quick cable fault location
• Light, compact and manageable
• Main unit for the tried-and-tested pre-location method
• Ideal for integration in measurement systems

 

BAUR PGK 70/2.5 HB HIGH-VOLTAGE TEST DEVICE

• Operation as DC or Ac testing device
• Polarity of the DC voltage can be easily be reserved
• Robust and durable

 

BAUR PGK 25 DC HIGH-VOLTAGE TEST DEVICE

• Compact device for DC voltage testing with negative polarity
• Continuously adjustable output voltage
• Perfect for mobile use