BAUR SSG Series Surge voltage generator

Cod: BAUR SSG 1100/1500/2100/3000


 

Brosura produs PDF, 0.66 Mb

Descriere

Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.

 

Features:

  • High surge voltage up to 32 kV
  • Continuously adjustable voltage
  • Voltage monitoring through kV meters with 3 measuring ranges
  • Automatic discharge unit
 

Alte produse BAUR

BAUR VIOLA AND VIOLA TD HIGH-VOLTAGE TEST AND DIAGNOSTICS DEVICE

• High performance and compact
• Precise and non-destructive determination of the cable condition
• Easy and quick test setup
• Automatic testing and diagnostic sequences

 

BAUR DTL C OIL BREAKDOWN VOLTAGE TESTER

• Fully automatic dissipation factor measurement
• Pre-programmed standards
• Maximum accuracy

 

BAUR ATG 2 BURN DOWN TRANSFORMER

• Portable device for changing the fault resistance
• Useful for cables that are difficult to access
• Proven methods for complicated faults
• Independent current and voltage control on each burning level

 

BAUR PGK 110/5 HB HIGH-VOLTAGE TEST DEVICE

• Testing as DC or Dc testing device
• Polarity of the DC voltage can easily be reversed
• Robust and durable

 

BAUR FRIDA TD VLF TESTING AND DIAGNOSTICS UNIT

• Cable testing and dissipation factor diagnostics in one device
• Easy and quick test setup
• Automatic testing and diagnostic sequences
• Compact dimensions and lightweight

 

BAUR SYSCOMPACT 2000 PORTABLE

• Fast and reliable
• Precise, dependable cable fault location
• High performance high voltage unit
• Integrated proven cable fault pre-location methods

 

BAUR TG 600 AUDIO FREQUENCY TRANSMITTER

• High-performance audio frequency transmitter up to 600 VA
• Frequency of 2 or 10 kHz, quartz-stabilised (other frequencies on request)
• Potential-free output
• Impedance adjustment in 8 steps from 0.3 to 300 O

 

BAUR PGK 50E / PGK 80E DC HIGH-VOLTAGE TEST DEVICE

• Continuous adjustable output voltage
• The voltage measurement is done directly at the high voltage output
• Timer of 1-30 min
• Sensitive current measurement for recording the smallest of insulation currents with 6-time range switch, decadal

 

BAUR PHG 70 TD PD / PHG 80 TD PD VLF TEST AND DIAGNOSTICS SYSTEM

• Compact, enclosed design in 19½ format
• Variable installation option with separate control and voltage unit
• Variable connection options to cable stations of different models

 

BAUR PGK 70/2.5 HB HIGH-VOLTAGE TEST DEVICE

• Operation as DC or Ac testing device
• Polarity of the DC voltage can be easily be reserved