Transformer Turn Ratio Tester Vanguard ATRT-01

Code: Vanguard ATRT-01 S3/ ATRT-01B S3


 

Datasheet PDF, 0.68 Mb
         

Description

  • Standalone or computer-controlled
  • Inexpensive
  • Displays turns-ratio from 0.8-15,000
  • Calculates turns-ratio percentage error
  • Displays winding polarity and phase angle
  • Displays excitation current
  • Battery or AC-powered (ATRT-01B S3 only)

 

The ATRT-01 S3 is Vanguard’s fourth generation, micro-processor based, single phase, automatic transformer turns-ratio tester. The ATRT-01 S3 uses the IEEE C57.12.90 measuring method to determine the transformer turns-ratio. The transformer turns-ratio is determined by precisely measuring the voltages across the unloaded transformer windings. The ATRT-01 S3’s measuring circuitry self adjusts before each measurement to ensure turns-ratio accuracy. Two selectable test voltages, 4Vac and 40Vac, offer flexibility in testing different types of transformers.

 

The ATR-01 S3 can measure transformer turns-ratios

ranging from 0.8 to 15,000 and can be used to test voltage

regulators, power transformers, current transformers

(CT), and potential transformers (PT). The ATRT-01

S3 also measures and displays transformer- winding

excitation current, winding polarity, and winding phase

angle. Test results are displayed on a back-lit LCD screen

(128 x 64 pixels) that is viewable in bright sunlight and

low-light conditions.

In addition to measuring a transformer’s turns-ratio, the

transformer’s name plate voltages can also be entered,

and the ATRT-01 S3 will then display the turns-ratio

percentage error. This convenient feature eliminates any

user calculation errors when testing transformers.

When testing a 3-phase transformer, the ATRT-01 S3

provides connection information (H and X test leads to

the transformer bushings) for phase A, B and C tests.

The three phase test results (turns-ratio, excitation current,

winding polarity, phaseangle, and percentage error)

are displayed on the LCD screen.

 

User Interface

The ATRT-01 S3 features a back-lit LCD screen

(128 x 64 pixels) that is viewable in direct sunlight

and low-light levels. A rugged 16-key membrane

keypad is used to enter test information

and to operate the unit.

 

Test Record Storage

The ATRT-01 S3 can store 128 records of 33 readings

internally, and up to 999 test records on an

external USB Flash drive. Test records can be

recalled using the included Transformer Analysis

PC software.

 

Computer Interface

A Windows®-based Transformer Analysis application

is provided with each unit and can be

used to remotely control the ATRT-01 S3 via the

RS-232C port. Using the Transformer Analysis

software, the user can retrieve test records

(from the ATRT-01 S3’s memory or a USB Flash

drive), analyze test results, and print test results

on a desktop printer. Test results are automatically

exported to Excel, PDF and XML formats.

 

Battery Power for Exceptional Portability

The ATRT-01B S3 is powered by a 6-volt, 7

ampere-hour, lead acid battery. This high capacity

battery, coupled with the ATRT-01B S3’s low

power consuming circuitry, allows the unit to be

used continuously for up to 4 hours per charge.

A built-in charger allows the unit to be used during

charging.

 

 

Standard accessories

Part number ATRT-01 S3 ATRT-01 S3 turns ratio tester, cables, and PC software

Part number ATRT-01B S3 ATRT-01B S3 turns ratio tester, cables, and PC software

Part number ATRT-01 S3-CABLE ATRT-01/01B S3 cables

Part number ATRT-01 S3-CASE ATRT-01/01B S3 shipping case

 

More products VANGUARD

THREE-PHASE TRANSFORMER WINDING RESISTANCE METER VANGUARD TRM-20

• accurately measure resistance from 1 micro-ohm to 2000 Ohms
• Perform three phase test on a transformer without the need to switch cables
• Can provide individual Delta winding resistance values
• Can provide individual Wye (with no neutral) winding resistance values
• Demagnetize transformer after test
• Selectable test current from 1A to 20A
• Computer control via RS-232C, USB, or Bluetooth interface
• Built-in 2.5" wide thermal printer

 

AUTOMATIC THREE-PHASE TRANSFORMER TURN RATIO METER VANGUARD ATRT-03A

• Capable of detecting 130 different 3-phase transformer types defined by ANSI, IEC, and Australian standards plus phase shifting transformers
• Store up to 128 transformer test-plans in Flash EEPROM
• Store up to 112 test records in Flash EEPROM
• Built-in USB Flash Drive Interface
• Computer Interface (RS-232C and USB Port)
• 4.5 Inch thermal printer
• Built-in transformer load tap changer

 

ON-LOAD TAP CHANGER ANALYZER AND WINDING RESISTANCE ANALYZER ON 3-PHASE TRANSFORMERS VANGUARD LTCA-40

• Auto discharge circuit for operator safety
• 3 resistance reading channels including one dynamic channel
• Digital resistance reading from 1 micro-ohm to 500 ohms
• 60Vdc power supply , outputting 40 amperes
• Calculate equivalent resistance value at reference temperature
• Stores 50 static records and 20 dynamic records
• Built-in 4.5-inch thermal printer

 

DIGITAL CIRCUIT BREAKER ANALYZER VANGUARD CT-8000

• dry-contact inputs 3 channels (9103-UC) or 6 channels (9104-UC)
• timing windows 1 second, 10 seconds, or 20 seconds
• timing resolutions ±50 micro-seconds @ 1 sec. duration
• Fully analyze circuit breaker's performance
• measuring main contact and resistor contact time, stroke, velocity, over-travel, bounce back and contact wipes
• USB computer interface
• Built-in 4.5" wide Thermal Printer

 

THREE-PHASE TRANSFORMER TURN RATIO TESTER VANGUARD ATRT-03 S2

• Highest ratio: 0.8 - 15,000
• Capable of detecting 130 different 3-phase transformer types defined by ANSI, IEC, and Australian standards
• 3 Test voltages available: 8Vac, 40Vac, 100Vac
• Phase angle and excitation current measuring
• Computer Interface (RS-232C and USB Port)
• USB flash drive interface
• Name-plate turns ratio calculation
• Computed % error based on measured and calculated ratio
• Optional 4.5" thermal printer

 

DC AUTOMATIC CIRCUIT BREAKER CONTACT RESISTANCE MICRO-OHMMETER 200A VANGUARD AUTO-OHM 200 S3

• 1 to 200A programmable test current
• Resitance range: 1µ?..10m? at 200A to 1µ?..5? at 1A
• Very lightweight: 16.8 lbs. (7.6 Kg)
• Measures circuit breaker contact resistance with safety ground on (with the Dual Ground option)
• Stores test records on-board or on external USB Flash drive
• Rugged, 44-key "QWERTY" membrane keypad
• Windows XP/Vista/7 Analysis Software (included with purchase)

 

MOLDED CASE CIRCUIT BREAKER TESTER VANGUARD MCCB-250

• 250 Ampere current source
• 4 current-source outputs (i.e., 5 A @ 120 Vac, 25 A @ 24 Vac, 120 A @ 6 Vac, 250 A @ 3 Vac)
• 4-line by 20-character LCD display
• Provides external current input (0-10 A)

 

DIGITAL BREAKER ANALYZER FOR CONTACT & SWITCH TIMING VANGUARD CT-3500

• Dry-contact inputs: 3 channels
• Trigger input voltage open/close: 30 ¬ 300 V, DC or peak AC
• Breaker operations: Open, Close, Open-Close, Close-Open
• Timing resolution: ±0.1 millisecond
• Detect Main & Insertion Resistor Contacts on same input
• USB computer interface
• Built-in 2.5" wide Thermal Printer

 

600A AC PRIMARY CURRENT INJECTION SOURCE FOR RELAY TESTING VANGUARD PCI-600

• Results displayed on a 4-line by 20-character backlit LCD
• Test currents from 10 to 600 amperes AC
• Also has an external-current input (0-10 A)
• timer reading range 1 m.. 2 hours

 

CURRENT TRANSFORMER TEST SET TURN RATIO, EXCITATION, SATURATION, POLARITY VANGUARD EZCT-2000A

• Perform Saturation, Ratio and Polarity Tests
• Perform CT Winding Resistance Test
• Fully Automated
• Test record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-comments
• Plot Multiple Saturation Curves
• Store 140 Records (of 10 Saturation Curves)
• Computer Interface
• USB Flash drive interface