Code: Vanguard CT-3500
Description
The CT-3500 S2 is Vanguard’s second generation, stand-alone, digital, microprocessorcontrolled, circuit-breaker timer. It measures the elapsed time from the instant a breaker coil is energized to the instant of opening or closing of a circuit-breaker’s dry contacts. In addition to timing a breaker’s contact response time, the CT-3500 S2 can also time relays or other switching functions that use an initiating trigger voltage (30- 300 Volts DC or AC). The timer-triggering voltage starts three independent electronic timers. Each timer is individually stopped by its respective dry-contact closing or opening.
The CT-3500 can fully analyze the timing of all circuit breaker operations (Open, Close, Open - Close, and Close - Open). Timing results are displayed in milli-seconds and cycles on the unit’s back-lit LCD screen and can be printed on the built-in 2.5-inch wide thermal printer.
Contact Timing Inputs
The CT-3500 S2 features three dry-contact, timer-channel monitoring inputs. The dry-contact
channel power supply is fuse-protected. All inputs are shunted to ground until the instant a test is initiated. All contact timing inputs are protected against static discharge. A contact self-test cable-mode is also available for testing cables or connections to the breaker.
Internal Test Record Storage
The CT-3500 S2 can store up to 128 test records in Flash EEPROM. Test records can be retrieved and printed on the built-in thermal printer, or they can be transferred to a PC via the unit’s USB interface. The USB interface can also be used for diagnostic testing and for updating firmware.
The CT-3500 S2 also features a USB Flash drive interface that can be used to store test records on an external USB Flash drive.
A Windows®-based Circuit Breaker Analysis application is provided with each unit and can be
used to transfer test records to a PC. Test records can also be reviewed, printed or exported in Excel, PDF, and XML formats for further analysis
User Interface
The CT-3500 S2 features a back-lit LCD screen (128 x 64 pixels) that is viewable in both bright sunlight and low-light levels. A rugged, 44-key, "QWERTY" membrane keypad is used to control the unit and input data. The unit's built-in 2.5- inch wide thermal printer can be used to print test reports.
More products VANGUARD
|
600A AC PRIMARY CURRENT INJECTION SOURCE FOR RELAY TESTING VANGUARD PCI-600
• Results displayed on a 4-line by 20-character backlit LCD |
|
DIGITAL BREAKER ANALYZER FOR CONTACT & SWITCH TIMING VANGUARD CT-3500
• Dry-contact inputs: 3 channels |
|
THREE-PHASE TRANSFORMER TURN RATIO TESTER VANGUARD ATRT-03
• Highest ratio: 0.8 - 15,000 |
|
CURRENT TRANSFORMER TEST SET TURN RATIO, EXCITATION, SATURATION, POLARITY VANGUARD EZCT-2000A
• Perform Saturation, Ratio and Polarity Tests |
|
DC CIRCUIT BREAKER CONTACT LOW RESISTANCE MICROOHMMETER 200A VANGUARD DMOM-200 S3
• 1 to 200A programmable test current |
|
PORTABLE RELAY TEST SET VANGUARD RFD-200
• Timer: 0 to 9.999 sec, 1 ms resolution; 10.00 to 99.99 sec, 10 ms resolution, 100.00 to 999.999 sec, 100 ms resolution |
|
DIGITAL BREAKER ANALYZER FOR CONTACT & SWITCH TIMING VANGUARD CT-7000
• dry-contact inputs: 3 channels (9021-UC) or 6 channels (9100-UC) |
|
TRANSOFORMER BREAKER CONTACT RESISTANCE MICRO OHM METER 600A VANGUARD DMOM-600
• 10 to 600A programmable test current |
|
MOLDED CASE CIRCUIT BREAKER TESTER VANGUARD MCCB-250
• 250 Ampere current source |
|
CURRENT TRANSFORMER TEST SET VANGUARD EZCT-10
• measurement method ANSI/IEEE C57.12.90, IEC 60044-1 and ANSI/IEEE C57.13.1 |