Metrel MI2077 TERAOHM Insulation Resistance Megohmmeter

Code: Metrel MI2077 MI-2077 TERAOHM


 

Datasheet PDF, 2.65 Mb
 

Description

Advanced, digital HV measuring instrument with maximum test voltage up to 5000 V DC and resistance measuring range up to 5 T?.

 

MEASURING FUNCTIONS

  • Automatic PI, DAR and DD index calculation and capacitance measurement up to 50µF.
  • Adjustable test voltage from 250 V to 5000 V in 50 V steps.
  • Resistance measuring range 5 T?.
  • Adjustable measuring time from 1 second to 90 minutes.
  • Automatic load discharge after completed measurement.
  • Guard terminal for elimination of insulation surface currents.
  • AC and DC voltage measurement up to 600 V.
  • Internal memory module stores up to 1000 measuring results.
  • Optional: 110 V version.

 

SOFTWARE

Optional software package TeraLink simplifies results evaluation.

 

TECHNICAL DATA

Dimensions (w x h x l): 265 x 110 x 185 mm

Weight (with batteries, without accessories): 2.3 kg

 

 

Standard accessories

MI 2077 Standard setMI 2077

  • Instrument TeraOhm 5 kV
  • Soft carrying bag
  • Mains cable
  • Test lead, black, 2 m
  • Test lead, red, 2 m
  • Guard lead, green, with crocodile clip, 2 m
  • Test probe, black
  • Test probe, red
  • Crocodile clip, black, 2 pcs
  • Handbook on CD
  • Instruction manual
  • Calibration certificate

 

 

 

More products METREL

METREL MI3121 INSOLATION RESISTANCE MEGOHMMETER 2500V AND CONTINUITY METREL MI 3121H SMARTEC 2.5KV

• Insulation resistance up to 100 GO with DC voltage up to 2.5 kV;
• PI, DAR calculation;
• Continuity of PE conductors with 200 mA test current and polarity change;
• Continuity of PE conductors with 7 mA test current (continuous measurement) without RCD tripping;
• TRMS voltage and frequency.

 

METREL MI2086 EUROTEST 61557 ELECTRICAL INSTALLATION TESTER

• DC insulation resistance with test voltages up to 1000V
• PE conductor continuity test
• Loop and Line impedance also without RCD triggering
• RCD test
• Illumination
• Phase sequence in 3-phase systems
• Measurements on earthling and lightning systems with included 2-clamp method (without junctions disassembling).
• Electrical power and consumption measurement,
• current and voltage harmonics measurement,
• phase angle

 

METREL MI3102 INSULATING RESISTANCE MEGOHMMETER 1000V, CONDUCTOR CONTINUITY, EARTHINGTEST EUROTEST XE

• DC insulation resistance,
• PE conductor continuity test,
• Line and Loop resistances with Fuse evaluation table built-in,
• RCD test with Trip lock function, phase sequence in 3-phase systems,
• on-line voltage monitor,
• 3-wire Earth resistance test with built-in battery operated generator,
• Leakage Current test,
• test of Luminance with optional LUX meter probe.

 

METREL MD9016 GENERAL PURPOSE HANDHELD MULTIMETER MD-9016

• 1000V AC, DC voltage measurement;
• 8A AC, DC current measurement;
• 600O..60MO Resistance measurement;
• 60nF..3mF Capacitance measurement;
• 5Hz..1MHz Frequency Measurement
• Temperature measurement(thermocouple type K included)

 

METREL MI3105 ELECTRICAL INSTALATION TESTER FOR INSULATION RESISTANCE, CONTINUITY, EARTH TEST MI 3105 EUROTEST XA

• insulation resistance,
• PE conductor continuity test,
• Line and Loop esistances with Fuse evaluation table built-in,
• RCD test with Trip lock function,
• phase sequence in 3-phase systems,
• on-line voltage monitor,
• 2-wire and 3-wire Earth resistance test with built-in battery operated generator,
• earth resistance test with Two Clamps method,
• Leakage Current test,
• test of Luminance with optional LUX meter probe

 

METREL MI2142 ALPHA-PAT ELECTRICAL SAFETY ANALYZER CF. IEC EN VDE STANDARD

• Functional and visual inspection;
• Earth bond resistance;
• Insulation resistance;
• Substitute leakage current;
• Differential leakage current test;
• Touch leakage test;
• IEC cord polarity test;

 

METREL MI3252 HIGH PRECISION MICROOHMMETER 100A

• Resistance measurement: wide measuring range (1 nO ... 20 O)
• adjustable test current (100 mA ... 100 A)
• Voltage drop measurement
• Bar graph: on screen resistance bar graph
• protection level (CAT IV, 50 V)
• Portable
• High protection degree: IP 64.
• Accurate: 1 nO best resolution with 0.25% accuracy
• Custom limits: the limits can be set for PASS or FAIL evaluation of test result.
• Battery powered
• Downloadable: downloads test results via RS232 or USB cable directly to the PC with the help of the software.

 

METREL MI3295 STEP CONTACT VOLTAGE MEASURING TEST SYSTEM

• Measurement of step voltage and contact voltage.
• Measurement of earthing resistance with resolution of 1 m?.
• Measurement of specific earth resistance.
• High current of up to 50 A and effective suppression of noise
• Excellent immunity even against changing earth currents.
• Autonomous Step Voltage meter: no need for long voltage leads.
• Downloads test results directly to the PC with the help of the professional PC SW package HVLink

 

METREL MI3122 SMARTEC Z RCD LOOP/ LINE IMPEDANCE SHORT-CIRCUIT CURRENT TESTER

• Loop impedance / prospective fault current
• Line impedance / prospective short-circuit current
• Built-in fuse characteristics for quick evaluation of measuring results
• RCD tests (trip out time, contact voltage, ramp test, Autotest)
• Testing on 1- and 3-phase systems
• Phase sequence test

 

PEN TYPE NON-CONTACT VOLTAGE DETECTOR METREL MD115

• 12 V … 1000 V AC measurement range
• Optical and vibrating indication
• CAT III / 1000 V overvoltage protection