Metrel MI3295 Step Contact Voltage Measuring Test System

Code: Metrel MI3295 MI-3295


 

Datasheet PDF, 0.39 Mb
 

Description

MI 3295 Step Contact Voltage Measuring System is a voltage measuring system for testing and verification of protective earthing of power stations, substations and other power systems.

 

MEASURING FUNCTIONS

  • Measurement of step voltage and contact voltage.
  • Measurement of earthing resistance with resolution of 1 m?.
  • Measurement of specific earth resistance.

 

KEY FEATURES:

  • High accuracy of the measurements due to a high current of up to 50 A and effective suppression of noise.
  • Excellent immunity even against changing  earth currents.
  • Autonomous Step Voltage meter: no need for long voltage leads.
  • Low weight.
  • High safety due to low output voltage (55 V).
  • Downloads test results directly to the PC with the help of the professional PC SW package HVLink which enables analysis and documenta-tion of test results.

 

TECHNICAL DATA

 

STATION

Dimensions (w x h x l): 563 X 275 X 257 mm

Weight (with batteries, without accessories): 29.5 kg

 

METER 

Dimensions (w x h x l): 230 X 103 X 115 mm

Weight (with batteries, without accessories): 1.3 kg

 

Standard accessories

MI 3295 Standard set MI 3295

  • Instrument MI 3295M
  • Instrument MI 3295S
  • Mains cable
  • Step voltage probe (25 kg), 2 pcs
  • Current earth spike
  • Potential earth spike
  • Current test lead, 50 m, black, 10 mm2, with crocodile clip, on wheel
  • Current test lead, 10 m, black, 10 mm2, with crocodile clip
  • Test lead, black, 2 x 3 m
  • Test lead, green, 10 m
  • Test lead, black, 1.5 m
  • Test lead, red, 50 m
  • Connection lead with crocodile clip, red, 1 m
  • Crocodile clip, 4 pcs
  • RS232 cable USB cable
  • Soft carrying bag, 2 pcs
  • Soft carrying neck belt
  • NiMH battery cells, type AA, 6 pcs
  • Power supply adapter
  • CD with instruction manual and PC SW HVLink PRO
  • Instruction manual
  • Calibration certificate

 

 

More products METREL

METREL MI2142 ALPHA-PAT ELECTRICAL SAFETY ANALYZER CF. IEC EN VDE STANDARD

• Functional and visual inspection;
• Earth bond resistance;
• Insulation resistance;
• Substitute leakage current;
• Differential leakage current test;
• Touch leakage test;
• IEC cord polarity test;

 

METREL MI3200 TERAOHM HIGH VOLTAGE INSULATION TESTER 10KV

• Insulation resistance up to 10 T?
• DC Test voltage 500 V - 10 kV in step of 25 V
• The short circuit current is 5 mA
• Auto-calibation of measuring system
• Operates from mains or rechargeable supply
• Automatic discharge of capacitive loads
• Digital and bar graph results with date and time
• User friendly PC software with RS232 or USB isolated communication port

 

METREL MD9050 PORTABLE DIGITAL HIGH RESOLUTION MULTIMETER MD-9050

• High resolution and accuracy
• 1000V TRMS AC, DC voltage measurement;
• 10A TRMS AC, DC current measurement;
• 60nF..25mF Capacitance measurement;
• 600O..60MO Resistance measurement;
• Diode test;
• 5Hz..1MHz Frequency of digital signals measurement
• Temperature measurement(thermocouple type K included)

 

POWER CURRENT CLAMP METER METREL MD 9240

• DC and TRMS AC voltage up to 600 V
• TRMS AC current measurement up to 1000 A
• Resistance measurement
• Continuity test
• Frequency measurement
• Contact temperature measurement
• Power factor
• Power (W, VA, Var)

 

LOW CURRENT LEAKAGE CLAMP METER METREL MD 9270

• TRMS AC voltage and current measurement.
• Frequency measurement.
• Power: measures various power parameters (active, reactive, apparent power, THD, PF, phase displacement).
• Intelligent loss analysis: complex algorithms detect loss and allow determining possible reasons for current loss.
• Harmonics: measures current or voltage harmonic components and a percentage value of a harmonic up to the 49th.
• Total Harmonic Distortion (THD)
• Power Factor (PF).

 

METREL MI2093 LINE TRACER FUSE FINDING INSTALLATION TESTER FOR UNDER-WALL CABLES

• Field proven instrument for under-wall low voltage installation tracing
• fuse finding
• short-circuit spot determination and metal installation tracing
• Can be used on energized or voltage-free systems.
• Tips and detailed descriptions of connection schemes for various combinations from everyday practice.

 

LOW COST UNIVERSAL CURRENT CLAMP METER METREL MD 9210

• DC and AC voltage up to 600 V
• AC current measurement up to 600 A
• Resistance measurement
• Continuity test
• Diode test
• Frequency measurement
• Capacitance measurement

 

METREL MI3102H INSULATING RESISTANCE TESTER 2500V CL ELECTRICAL INSTALLATIONS EUROTEST XE 2.5KV

• Insulation resistance with up to 2500V DC voltage
• PI, DAR calculation
• Continuity of PE conductors with 200 mA test current with polarity change
• Continuity of PE conductors with 7 mA test current (continuous measurement) without RCD tripping
• Line impedance
• Loop impedance
• Loop impedance with Trip Lock RCD function
• TRMS voltage and frequency

 

METREL MI3122 SMARTEC Z RCD LOOP/ LINE IMPEDANCE SHORT-CIRCUIT CURRENT TESTER

• Loop impedance / prospective fault current
• Line impedance / prospective short-circuit current
• Built-in fuse characteristics for quick evaluation of measuring results
• RCD tests (trip out time, contact voltage, ramp test, Autotest)
• Testing on 1- and 3-phase systems
• Phase sequence test

 

1000V VOLTAGE CONTINUITY TESTER METREL MD1050

• Voltage testing up to 1000 V
• Automatic AC/DC recognition
• Continuity buzzer and led to indicate resistances below 500 k?
• Phase & Rotating Field Test
• RCD trip testing
• Diode Test
• Auto Power Off