Reflectometru TDR localizare defecte cablu Megger TDR500/3

Cod: Megger TDR500/3 1002-227


 

Brosura produs PDF, 0.28 Mb

Descriere

• Simple operation.
• AUTO selection of gain and pulse width.
• Ultra fast pulse for near end fault identification.
• Trace HOLD feature.
• IP54 rating offers real life working.
• Designed for use on all metallic cable pairs.

 

 

The TDR500/3 is a hand held, compact Time Domain Reflectometer for locating faults on metallic cables. It has a minimum resolution of 0.1 m and a 5 km maximum range depending on velocity factor selected and cable type.

Four output impedances are available (25, 50, 75, and 100 O) and a velocity factor between 0.2 and 0.99 will meet any cable test requirements.

 

Accesorii standard

Time Domain Reflectometer 1002-227

Included accessories

Hard carry case 5410-420

Miniature clip test lead set 6231-652

User guide CD 2002-178

 

Optional accessories

Fused test lead set 1002-015

 

Alte produse MEGGER

MEGGER - B10E

• Reliable and stable a.c. and d.c. power supply for circuit breaker testing
• Continuously variable 24-250 V AC or DC output
• Separate outputs for close coil, trip coil and spring charging motor voltage
• Direct triggering for minimum trip voltage testing

 

TRUSA MONOFAZATA CURENT-TENSIUNE TESTARE RELEE MEGGER SVERKER 650

• Designed for rugged field use
• 0 to 100 Amp output current
• Suitable for testing many different types of relays such as power, voltage and current
• Easy to operate

 

TRUSA MASURA TANGENTA UNGHI DE PIERDERI TANGETA DELTA MEGGER DELTA4310

• fully automatic 12 kV insulation power factor / dissipation factor (tan delta) test set
• Voltage: 25 V to 12 kV, 1 V resolution
• Current : 0 to 5 Amps, 0.1 µA maximum resolution
• Capacitance: 0 to 100 µF, 0.01 pF maximum resolution
• Inductance: 6 H to 10 MH, 0.1 mH maximum resolution
• Power factor PF : 0-100% (0-1), 0.001% maximum resolution
• Dissipation factor DF : 0-100 (0-10,000%), 0.001% maximum resolution
• Watt Loss: 0 to 2 kW
• Automatic and manual operation
• Accurate and repeatable measurement results with high noise suppression
• Lightweight, rugged two-piece design

 

TESTER IZOLATIE 2500V 2.5KV MEGGER MIT2500

• Testarea izolaţiei până la 2,5 kV şi intervalul de 200 GΩ într-un instrument portabil
• Terminal de protecţie pentru precizie ridicată a rezistenţei
• Tensiune de testare a izolaţiei reglabilă de la 50 V la 2500 V
• Tensiune de testare a izolaţiei stabilizată
• Funcţii de testare suplimentare PI şi DAR

 

PHOTOVOLTAIC KIT MEGGER - PVK320

• PVM210 irradiance meter
• AVO410 CATIV TRMS multimeter
• C4 solar connectors to 4 mm standard plug test leads
• MC3 to MC4 adapter test leads
• PV kit storage pouch

 

TRMS CLAMP METER MEGGER - DCM1500

• DC and AC current up to 1500 A
• True RMS measurement for greater accuracy
• Large jaw size safely assists with uninsulated conductor measurements
• 750 Vac and 1000 Vdc

 

AC VOLTAGE DETECTORS MEGGER - VF3

• Non-contact detection of AC voltage
• Automatic audible warning buzzer
• Bright red voltage indicator in tip
• Ultra bright LED torch

 

BATTERY GROUND FAULT LOCATOR MEGGER - BGL

• Ground faults in ungrounded dc battery systems easily located
• Operates in high electrical noise environment
• Simplifies fault tracing by identifying fault characteristic (resistive and capacitive) magnitudes

 

TRUSA AVANSATA PRIZE DE PAMANT INALTA PRECIZIE SI REZOLUTIE MEGGER DET2/3

• Rezoluție înaltă de 1 mΩ, ideală pentru sisteme de împământare mari
• Moduri de testare versatile
• Precizie ridicată pentru testele de rețea ale electrodului de împământare/masă și rezistivitatea solului
• Baterie reîncărcabilă care poate dura toată ziua cu o reîncărcare rapidă (până la 10 ore)
• Instrument robust cu protecție IP65
• Selectare automată a frecvenței de testare, cu filtre și funcții de curent ridicat

 

PRIMARY CURRENT INJECTION TEST SYSTEM MEGGER INGVAR

• Most advanced primary current injection test system to simplify all types of switchgear and CT commissioning, ground grid, circuit breaker testing and more
• Up to 5000 A output current
• Two units, each of about 20 kg, makes it easier to carry
• Unique I/30 function allows the current to be pre-set using low current to prevent test sample heating, thus eliminating corruption of test result