Insulation Megohmeter 5kV Chauvin Arnoux CA6505

Code: Chauvin Arnoux CA6505


 

Datasheet PDF, 0.72 Mb

Description

The C.A 6505 makes industrial equipment inspection and maintenance testing particularly

simple.

 

  • Adjustable test voltage: 40 V to 5,100 V in 10 or 100 V increments
  • 500 V: 10 kO to 2 TO
  • 1,000 V: 10 kO to 4 TO
  • 2,500 V: 10 kO to 10 TO
  • 5,000 V: 10 kO to 10 TO

 

In its site-proof casing suitable for even the severest conditions, the C.A 6505 offers optimum accuracy and expertise for insulation testing.

As soon as it is connected, it measures the voltage, frequency, capacitance and residual current values on the installation or equipment to be tested.

The C.A 6505 megohmmeter is delivered in a bag with 2 measurement leads 2 m long, crocodile clips and 2 guarded safety leads.

 

Standard accessories

½ C.A 6505 Megohmmeter ................................. P01139704

Delivered with a carrying bag containing:

½ 2 simplified measurement leads 2 m long, equipped with an HV plug at

each end (red / blue)

½ 1 guarded safety lead 2 m long, equipped with an HV plug at one end and

an HV plug with rear connection at the other end (black)

½ 1 guarded safety lead 0.35 m long, equipped with an HV plug at one end and

an HV plug with rear connection at the other end (blue)

½ 3 crocodile clips (red, blue and black)

½ 1 mains power cable 1.80 m long

½ 1 operating manual in 5 languages

 

 

Recommended options

 

 

More products CHAUVIN ARNOUX

DIGITAL INSULATION MEGOHMMETER 100V CHAUVIN ARNOUX CA6531

• insulation: up to 400MO at 50V and 100V
• AC voltage measurement: 0 to 400V
• voltage indication before measurement of insulation: 0 to 600V AC/DC (blocking if U>25V)
• resistance: 0 to 40kO
• capacity: 0 to 4000nF
• current: 0 to 400mA AC/DC


DIGITAL INSULATION MEGOHMMETER 1KV CHAUVIN ARNOUX CA6525

• insulation: up to 2G? at 250V, 500V and 1,000V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep and compensation of leads)
• resistance: 0 to 400k?
• giant 4,000-count display + bargraph


EARTH GROUND RESISTANCE TESTER ON PYLONS CHAUVIN ARNOUX CA6472

• 5 tools in 1 with this tester
• extensive measurement ranges: 0.001?to 100 k?
• analysing the frequency behaviour of the earthing systems (from 41 Hz to 5 kHz)
• high-level, expert calculation capabilities
• IP 53 leakproofing

 

EARTHING RESISTANCE TESTER CHAUVIN ARNOUX CA6470N TERCA3

• extensive measurement ranges: 0.001? to 100 k?
• adjustment of the measurement frequency between 41 Hz and 512 Hz
• 10 times greater accuracy due to its 4-pole measurement method
• measuring soil resistivity
• calculate r automatically by the Wenner or Schlumberger methods

 

DIGITAL INSULATION MEGOHMMETER 1000V CHAUVIN ARNOUX CA6523

• insulation: up to 2G? at 500V and 1,000V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep and compensation of leads)
• resistance: 0 to 400k?
• giant 4,000-count display + bargraph


ENERGY POWER ANALYZER CHAUVIN-ARNOUX CA8230

• Voltage range: 6VRMS to 600VRMS AC+DC
• AC current range: 5mA to 6,500A
• DC current range: 1A to 1,700A
• Values: Min., Max., Avg., Peak (+/-), CF
• Power: W, VA, var, DF, THD, cos f, tan f
• Energy: Wh, VAh, varh
• Harmonics: up to the 50th order
• IEC1010/EN61010: Cat.III-600V

 

DIGITAL INSULATION MEGOHMMETER 5KV CHAUVIN ARNOUX CA6549

• measurement range: 10k? to 10T?!
• 4 fixed test voltages: 500 / 1,000 / 2,500 and 5,000V
• adjustable test voltage position: 40 to 5,100V in 10V or 100V increments
• step voltage mode: R(Utest) measurement curve viewed on the screen and gradient calculated automatically in ppm/V
• DAR, PI and DD quality ratios calculated automatically
• programmable test length and R(t) measurement curve

 

EARTH RESISTANCE DIGITAL TESTER CHAUVIN ARNOUX CA6423

• earth resistance: 0.00 to 2,000O (3 cal.)
• 3 fault presence indicators to validate the measurement
• measurement frequency: 128Hz
• connection of rods to colour-coded terminals
• a removable captive connection strip between H and S for measurement of 2-wire resistance
• large 2,000-count digital display with 18mm digits: excellent readability


ANALOGUE MEGOHMMETER 1000V CHAUVIN ARNOUX CA6513

• insulation: up to 1,000MO (1 cal.) at 500V and 1,000V DC
• AC voltage: 0 to 600V
• resistance: 0 to 1,000O
• continuity: -10O to +10O (I=200mA)
• automatic testing of voltage absence by direct measurement


ELECTRICAL MACHINE CERTIFICATION TESTER CHAUVIN ARNOUX CA6160

• dielectric test: standard measurement modes (Un from 100 to 5,000V with Ilim 500mA) and programmed modes (t1, t2, t3, U1, U2)
• continuity: up to 100O with 0.1 < ITEST < 25A
• voltage drop: up to 100V (Itest > 10A)
• insulation resistance: up to 1GO at 250/500VDC and 1,000VDC
• measurement of internal and external discharge time (at the plug)
• leakage current: operating and residual up to 20mA, contact up to 2mA
• functional testing: voltage, current, frequency and power