Insulation Megohmeter 5kV Chauvin Arnoux CA6505

Code: Chauvin Arnoux CA6505


 

Datasheet PDF, 0.72 Mb

Description

The C.A 6505 makes industrial equipment inspection and maintenance testing particularly

simple.

 

  • Adjustable test voltage: 40 V to 5,100 V in 10 or 100 V increments
  • 500 V: 10 kO to 2 TO
  • 1,000 V: 10 kO to 4 TO
  • 2,500 V: 10 kO to 10 TO
  • 5,000 V: 10 kO to 10 TO

 

In its site-proof casing suitable for even the severest conditions, the C.A 6505 offers optimum accuracy and expertise for insulation testing.

As soon as it is connected, it measures the voltage, frequency, capacitance and residual current values on the installation or equipment to be tested.

The C.A 6505 megohmmeter is delivered in a bag with 2 measurement leads 2 m long, crocodile clips and 2 guarded safety leads.

 

Standard accessories

½ C.A 6505 Megohmmeter ................................. P01139704

Delivered with a carrying bag containing:

½ 2 simplified measurement leads 2 m long, equipped with an HV plug at

each end (red / blue)

½ 1 guarded safety lead 2 m long, equipped with an HV plug at one end and

an HV plug with rear connection at the other end (black)

½ 1 guarded safety lead 0.35 m long, equipped with an HV plug at one end and

an HV plug with rear connection at the other end (blue)

½ 3 crocodile clips (red, blue and black)

½ 1 mains power cable 1.80 m long

½ 1 operating manual in 5 languages

 

 

Recommended options

 

 

More products CHAUVIN ARNOUX

EARTH GROUND RESISTANCE TESTER ON PYLONS CHAUVIN ARNOUX CA6474

• Ideal for earth measurements on pylons
• measurement range: 0.001 O to 99.99 kO
• resolution: 0.001 to 10 O
• no-load voltage: 16 or 32 VRMS
• measurement frequency: 41 Hz to 5,018 Hz
• measurement of resistance of earth stakes: 0.01 O to 100kO
• leakproofing: IP53

 

DIGITAL INSULATION MEGOHMMETER 500V CHAUVIN ARNOUX CA6521

• insulation: up to 2G? at 250V and 500V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep)
• giant 400-count display + bargraph (simultaneous reading of measurement and analogue variance)
• back stand for use on a table or on the ground
• long battery life: 6 x 1.5V batteries


DIGITAL INSULATION MEGOHMMETER 5KV CHAUVIN ARNOUX CA6549

• measurement range: 10k? to 10T?!
• 4 fixed test voltages: 500 / 1,000 / 2,500 and 5,000V
• adjustable test voltage position: 40 to 5,100V in 10V or 100V increments
• step voltage mode: R(Utest) measurement curve viewed on the screen and gradient calculated automatically in ppm/V
• DAR, PI and DD quality ratios calculated automatically
• programmable test length and R(t) measurement curve

 

DIGITAL INSULATION MEGOHMMETER 1000V CHAUVIN ARNOUX CA6523

• insulation: up to 2G? at 500V and 1,000V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep and compensation of leads)
• resistance: 0 to 400k?
• giant 4,000-count display + bargraph


ANALOGUE MEGOHMMETER 1000V CHAUVIN ARNOUX CA6513

• insulation: up to 1,000MO (1 cal.) at 500V and 1,000V DC
• AC voltage: 0 to 600V
• resistance: 0 to 1,000O
• continuity: -10O to +10O (I=200mA)
• automatic testing of voltage absence by direct measurement


INSULATION MEGOHMMETER 5000V CHAUVIN ARNOUX CA6545

• wide range from 30k? to 10T? !
• 4 fixed test voltages: 500/1,000/2,500 and 5,000V
• programmable test voltage position: from 40 to 5,100V in increments of 10V or 100V
• giant backlit LCD screen with digital display + bargraph
• qualitative analysis: automatic calculation of DAR, PI and DD

 

THREE-PHASE POWER QUALITY ANALYZER CHAUVIN-ARNOUX CA8435

• C.A 8435, the rugged, waterproof IP67
• Indoor and outdoor use, even when it is raining
• 5 voltage inputs, 4 current inputs
• Continuous recording of all the parameters simultaneously
• Monitoring with alarms
• All types of installations
• Measurement of P, Q, S and D power values (total and per phase)
• Calculation of Pst & Plt flicker values

 

EARTHING RESISTANCE TESTER CHAUVIN ARNOUX CA6471

• extensive measurement ranges: 0.001? to 100 k?
• adjustment of the measurement frequency between 41 Hz and 512 Hz
• 10 times greater accuracy due to its 4-pole measurement method
• measuring soil resistivity
• calculate r automatically by the Wenner or Schlumberger methods
• Ergonomic, comprehensive and accurate

 

ELECTRICAL MACHINE CERTIFICATION TESTER CHAUVIN ARNOUX CA6160

• dielectric test: standard measurement modes (Un from 100 to 5,000V with Ilim 500mA) and programmed modes (t1, t2, t3, U1, U2)
• continuity: up to 100O with 0.1 < ITEST < 25A
• voltage drop: up to 100V (Itest > 10A)
• insulation resistance: up to 1GO at 250/500VDC and 1,000VDC
• measurement of internal and external discharge time (at the plug)
• leakage current: operating and residual up to 20mA, contact up to 2mA
• functional testing: voltage, current, frequency and power

 

INSULATION MEGOHMMETER 500V CHAUVIN ARNOUX CA6511

• insulation: up to 1,000MO (1 cal.) at 500V DC
• AC voltage: 0 to 600V
• continuity: -10? to +10? (I=200mA)
• automatic testing of absence of voltage by direct measurement
• single input on two colour-coded terminals