Pirgeometru meteo masura radiatie infrarosu Delta Ohm LP PIRG01

Cod: Delta Ohm LP PIRG01


 

Brosura produs PDF, 0.88 Mb

Descriere

The pyrgeometer LP PIRG 01 is used to measure the far infrared radiation (FIR).

Its use is mainly in the meteorological field. Measures are referred to radiations

with wavelength greater than 4.5 µm .

The far infrared radiation derives from the measure of the thermopile output

signal and from the knowledge of the instrument temperature. The temperature

measure is performed by a 10kO NTC which is inside the body of the pyrgeometer.

The pyrgeometer can be used also for the study of energy balance. In this case,

besides another pyrgeometer which measures infrared radiation upwards, it is

necessary an albedometer (LP PYRA 05 or LP PYRA 06) to measure short wavelengths

radiation (<3µm) .

 

Alte produse SENSECA

DATALOGGER HVACR VITEZA SI DEBIT AER, PRESIUNE, TEMPERATURA, UMIDITATE DELTA OHM DO2003

• HVACR Datalogger to measure: air speed and flow rate with the hot wire probes, vane probes, Pitot tube probes,
• Pt100 temperature probes for immersion, pointed and for surface,
• combined temperature/relative humidity probes.
• Pressure up to 2000 mbar and barometric pressure.
• Max-Min-Med, Rel measurements.
• Storage up to 12,000 readings.
• Serial output RS232C


PIRHELIOMETRU CLASA INTAI MASURA IRADIERE DIRECTA FLUX SOLAR DELTA OHM LP PIRHE16

• The pyrheliometer LP PYRHE 16 First Class Pyrheliometer according to ISO 9060 classification
• is an instrument for direct measurement of solar irradiance (Watt/m2).
• The receiving surface must be positioned (via a solar tracker or else) perpendicularly to sun’s rays.
• By using suitable diaphragms only the direct light reaches the surface of the sensor.
• According to WMO (Seventh Edition 2008) and ISO 9069 regulations, the pyrheliometer has a field of view of 5°.

 

LUXMETRU FOTO-RADIOMETRU MASURA ILUMINANTA, PAR, IRADIANTA SOLARA DELTA OHM HD2102.1 HD2102.2

• Device for measuring illuminance, luminance, PAR, irradiance.
• Storage of maximum, minimum, average value and the integral Q(t),
• RS232 C output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

DATALOGGER ANALIZA MONITORIZARE CALITATE MEDIU AER, MONOXID, BIOXID CARBON DELTA OHM HD37AB17D HD37B17D

• data loggers able to measure and memorize simultaneously the following parameters:
• Relative Humidity RH
• Environment temperature T
• Carbon monoxide CO (only HD37AB17D)
• Carbon dioxide CO2
• DeltaLog13 communication software via the USB port

 

KIT CALIBRARE PH-METRE SI MV-METRE CU SIMULATOR DELTA OHM HD9609

• pH/mV simulator kit composed of instrument HD9609,
• adapter cables CP 9509/T,
• CP9509/BNC and
• carrying case.

 

TERMOMETRU DE PRECIZIE PORTABIL DELTA OHM HD2107.1 HD2107.2 HD2127.1 HD2127.2

• Centesimal thermometer in the range +/-199.99°C, decimal outside this range
• one input for Pt100 probes with SICRAM module measuring range -200°C +650°C
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power

 

MANOMETRE-TERMOMETRE DIGITALE DELTA OHM HD2114 HD2134 HD2164

• portable instruments with a large LCD display
• They measure absolute, relative and differential pressure, as well as temperature
• Max, Min and Avg function calculates the maximum, minimum or average values
• relative measurement REL, the HOLD function, and the automatic turning off
• store up to 36,000 samples
• standard RS232C serial port and USB 2.0

 

SONOMETRU INTEGRATOR CLASA I / CLASA II CU DATALOGGING, ANALIZA SPECTRALA SI STATISTICA DELTA OHM HD2010UC/A

• portable integrating class 1 sound level meter, with data logging function, suitable for performing statistical and spectral analyses
• possibility of adjusting the instrument and adding options at any time
• user can upgrade the firmware directly by means of the Noise Studio programme supplied with the instrument
• Class 1 or 2 sound level meter according to IEC 61672-1 IEC 60651 and IEC 60804
• Class 1 octave and third octave filters according to IEC 61260
• Assessment of the environmental noise level,
• Noise monitoring and optional capture and analysis of sound events,
• Octave and optional third octave band spectrum analysis from 25 Hz to 12.5 kHz,

 

PIRGEOMETRU METEO MASURA RADIATIE INFRAROSU DELTA OHM LP PIRG01

• The pyrgeometer LP PIRG 01 is used to measure the far infrared radiation (FIR).
• Its use is mainly in the meteorological field.
• Measures are referred to radiations with wavelength greater than 4.5 µm .
• The far infrared radiation derives from the measure of the thermopile output signal and from the knowledge of the instrument temperature. The temperature measure is performed by a 10kO NTC which is inside the body of the pyrgeometer.
• The pyrgeometer can be used also for the study of energy balance

 

RADIOMETRU NET CU 4 COMPONENTE MASURA RADIATII SOLARE DELTA OHM LP NET14

• LP NET 14 is a 4-component net-radiometer for the measurement of the net radiation between 0.3µm and 45 µm.
• consists of two pyranometers: one for the measurement of the global radiation Esw? and the other one for the measurement of the reflected solar radiation Esw?
• pair of pyrgeometers: one for the measurement of the infrared radiation emitted by the sky EFIR? and the other one for the infrared emitted by the ground surface EFIR?
• equipped with a temperature sensor (NTC).