Datalogger HVACR viteza si debit aer, presiune, temperatura, umiditate Delta Ohm DO2003

Cod: Delta Ohm DO2003


 

Descriere

HVACR Datalogger to measure: air speed and flow rate with the hot wire probes, vane probes, Pitot tube probes, Pt100 temperature probes for immersion, pointed and for surface, combined temperature/relative humidity probes. Pressure up to 2000 mbar and barometric pressure. Max-Min-Med, Rel measurements. Storage up to 12,000 readings. Serial output RS232C. Configurable storing and printing interval. The kit is provided with the instrument DO2003, carrying case, instruction manual, 4 batteries, Software DeltaLog 3. The air speed probes, Pitot tubes, temperature probes, temperature and humidity probes, pressure probes and cables for data download (9CPRS232) have to be ordered separately.

 

Alte produse SENSECA

PIRANOMETRU CLASA A 2A IN CONFORMITATE CU STANDARDUL ISO9060 DELTA OHM LP PYRA08

• Second class pyranometer according to ISO 9060,
• fast response sensor complete with calibration report,
• possibility to replace the exhausted silica-gel.
• Different configurations available.
• Male M12 connector.
• On request cables with M12 female connector: CPM12AA, length 2, 5, 10m.

 

PH-METRU PORTABIL CU TERMOMETRU DELTA OHM HD2305.0

• pHmeter-Thermometer which measures pH, mV and temperature.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

CONDUCTIVIMETRU-TERMOMETRU MASURA CONDUCTIVITATE, REZISTIVITATE LICHIDE, SOLIDE DIZOLVATE, SALINITATE, TEMPERATURA DELTA OHM HD2106.1 HD2106.2

• Conductivity-Thermometer measures conductivity, liquid resistivity, total dissolved solids, salinity and temperature.
• Datalogger which can store the maximum, minimum, average value and can store up to 36,000 samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

CALIBRATOR ACUSTIC NIVEL SUNET PENTRU CALIBRARE MICROFON SI STATII ACUSTICE DELTA OHM HD2020

• HD 2020 sound level calibrator
• portable, battery operated sound source
• suitable for sound level meters (portable and laboratory) and acoustic stations
• class 1 according to IEC60942:2003 with LCD display.
• ISO 9001 calibration report included.
• 1000Hz frequency allows calibrating sound level meters with any weighting

 

LUXMETRU MASURA ILUMINANTA, PAR, IRADIANTA LUMINA SOLARA DELTA OHM HD2302.0 HD2302.0VP474

• Device for measuring illuminance, luminance, PAR, irradiance
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

SONOMETRU INTEGRATOR PORTABIL DE CLASA I CU ANALIZA SPECTRU OCTAVA SI STATISTICI DELTA OHM HD2010

• precision integrating portable sound level meter
• data logging functions
• performing both spectrum and statistical analysis
• maximum flexibility and simplicity
• firmware can be directly updated by the user by means of the Noise Studio program supplied with the instrument
• Class 1 sound level meter according to IEC 61672-1, 2002
• Class 1 octave and third octave filters according to IEC 61260
• Microphone complying with IEC 61094-4
• Noise monitoring and optional capture and analysis of sound events
• Octave and optional third octave band spectrum analysis from 16 Hz to 20 kHz

 

CONDUCTIVIMETRU-TERMOMETRU DE LABORATOR CU MASURA REZISTIVITATE LICHIDE, SOLIDE DIZOLVATE TDS DELTA OHM HD2206.2

• Bench-top conductivity meter-Thermometer with back-lighted display,
• with inputs for measurements of conductivity, liquid resistivity, total dissolved solids (TDS) and the salinity by conductivity and temperature
• combined probes with 2 or 4 electrodes with direct input or with SICRAM module.
• Datalogger of conductivity or resistivity or TDS and temperature.
• RS232 C or USB 2.0 serial output for data download to a PC or printer from memory or in real time.
• Input for Pt100 or Pt1000 temperature probes provided with SICRAM module.

 

TERMOMETRU DIGITAL PORTABIL TERMOCUPLU K, J, T, R, N, S, B, E DELTA OHM HD2108.1 HD2108.2 HD2128.1 HD2128.2

• Thermocouple thermometer with one input and logger 32.000 samples
• For K, J, T, R, N, S, B, E type probes with miniature connector
• Storage of maximum, minimum, average value,
• USB/RS232 C connection to download loggerdata to PC.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

TERMOMETRU DIGITAL PORTABIL TERMOCUPLU K J T E DELTA OHM HD2328.0

• Thermocouple thermometer for probes type K, J, T, E
• Two inputs for miniature thermocouple connectors
• Storage of maximum, minimum, average valu
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

PIRANOMETRU CLASA SECUNDARA MASURA IRADIERE SOLARA DIRECTA SI GLOBALA PE SUPRAFATA PLANA DELTA OHM LP PYRA10

• measures the irradiance on a flat surface (Watt/m2)
• pyranometer classified as Secondary in accordance with ISO 9060
• according to the publication "Guide to Meteorological Instruments and Methods of Observation", fifth edition (1983) of WMO
• LP PYRA 10 PASSIVE *
• LP PYRA 10 AC ACTIVE with CURRENT 4..20 mA output
• LP PYRA 10 AV ACTIVE with VOLTAGE 0..1 V, 0..5 V, 0..10 V output