Tester monitorizare si analiza calitate aer interior, monoxid, bioxid de carbon Delta Ohm HD37AB1347

Cod: Delta Ohm HD37AB1347


 

Brosura produs PDF, 0.41 Mb

Descriere

Datalogger for indoor air quality analysis (IAQ). The instrument measures the quantities: airspeed, temperature, relative humidity, atmospheric pressure, CO2 (Carbon Dioxide) and CO (Carbon Monoxide, only with P37AB147 probe). The SICRAM hotwire air speed probes, vane air speed probes, temperature probes, relative humidity and temperature combined probes can also be connected to the instrument. Memory capacity of 67,600 records for each of the two inputs. Logging interval from 15 seconds to 1 hour.

 

 

Alte produse SENSECA

DATALOGGER FOTO-RADIOMETRU LUMINA SOLARA, TEMPERATURA DELTA OHM DO9721

• Datalogger Photo-radiometer Thermometer which performs photometric, radiometric, PAR, temperature measurements.
• Two inputs.
• Function as datalogger: 30,000 samples, REL, Record, Q (integration),
• RS232C serial output

 

CONDUCTIVIMETRU-TERMOMETRU MASURA CONDUCTIVITATE, REZISTIVITATE LICHIDE, SOLIDE DIZOLVATE, SALINITATE, TEMPERATURA DELTA OHM HD2106.1 HD2106.2

• Conductivity-Thermometer measures conductivity, liquid resistivity, total dissolved solids, salinity and temperature.
• Datalogger which can store the maximum, minimum, average value and can store up to 36,000 samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

TERMOMETRU DIGITAL PORTABIL TERMOCUPLU K J T E DELTA OHM HD2328.0

• Thermocouple thermometer for probes type K, J, T, E
• Two inputs for miniature thermocouple connectors
• Storage of maximum, minimum, average valu
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

LUXMETRU MASURA ILUMINANTA, PAR, IRADIANTA LUMINA SOLARA DELTA OHM HD2302.0 HD2302.0VP474

• Device for measuring illuminance, luminance, PAR, irradiance
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

SONOMETRU INTEGRATOR CLASA I / CLASA II CU DATALOGGING, ANALIZA SPECTRALA SI STATISTICA DELTA OHM HD2010UC/A

• portable integrating class 1 sound level meter, with data logging function, suitable for performing statistical and spectral analyses
• possibility of adjusting the instrument and adding options at any time
• user can upgrade the firmware directly by means of the Noise Studio programme supplied with the instrument
• Class 1 or 2 sound level meter according to IEC 61672-1 IEC 60651 and IEC 60804
• Class 1 octave and third octave filters according to IEC 61260
• Assessment of the environmental noise level,
• Noise monitoring and optional capture and analysis of sound events,
• Octave and optional third octave band spectrum analysis from 25 Hz to 12.5 kHz,

 

ANALIZOR AUDIO SUNET CLASA I CU DATALOGGER, ANALIZA SPECTRU ACUSTIC OCTAVA 3A, STATISTICI DELTA OHM HD2110L

• precision integrating portable sound level meter
• data logging function
• performing both spectrum and statistical analysis
• high-performance analysis of acoustic phenomena
• Class 1 sound level meter according to IEC 61672-1, 2002 , IEC 60651 and IEC 60804
• Class 1 octave and third octave filters according to IEC 61260
• Real-time octave and third octave band spectrum analysis from 16 Hz to 20 kHz
• Narrow-band spectral analysis (FFT) with variable resolution from 1.5Hz to 100Hz and capture of the Leq profile at intervals of 1/32s

 

PIRHELIOMETRU CLASA INTAI MASURA IRADIERE DIRECTA FLUX SOLAR DELTA OHM LP PIRHE16

• The pyrheliometer LP PYRHE 16 First Class Pyrheliometer according to ISO 9060 classification
• is an instrument for direct measurement of solar irradiance (Watt/m2).
• The receiving surface must be positioned (via a solar tracker or else) perpendicularly to sun’s rays.
• By using suitable diaphragms only the direct light reaches the surface of the sensor.
• According to WMO (Seventh Edition 2008) and ISO 9069 regulations, the pyrheliometer has a field of view of 5°.

 

DATALOGGER MULTIFUNCTIONAL CU ANALIZA MICROCLIMA DELTA OHM HD32.1

• Globe temperature
• Natural wet bulb temperature
• Ambient temperature
• Atmospheric pressure
• Relative Humidity
• Air velocity
• Air temperature at the height of the head...

 

ANEMOMETRU-TERMOMETRU DIGITAL DELTA OHM HD2103.1 HD2103.2

• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module.
• Datalogger which stores the maximum, minimum, average value and can store up to 38,000 samples.
• RS232C/USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP67 protection degree.

 

TERMOMETRU DIGITAL PORTABIL SENZOR PT100 -200°C +650°C DELTA OHM HD2307.0

• Thermometer, Pt100 sensor with one input for probes equipped with SICRAM module,
• measuring range -200°C +650°C
• Storage of maximum, minimum, average value
• Functions: REL, HOLD and auto-power-off which can be disabled
• IP 67 protection degree